Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹76.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹90.6 L+₹14.1 L (18.4%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical licence submitted is C class |
Tender Value
₹81.0 L
EMD Value
₹50,000
Closing Date
8 Jul 2019, 5:00 pmClosed
Superintending Engineer
Thiruvananthapuram Corporation
Electrification and solar works of Park in Poundukadavu station kadavu road in Thiruvananthapuram corporation under Amrut scheme
2019_LSGD_284135_1
Tvpm CorpE13/76092(A)/19
Open Tender
Electrical Works
Item Rate
180 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Yes
online
₹50,000
Yes
10 Mar 2020
29 Jun 2019
11 Jul 2019
29 Jun 2019
8 Jul 2019
29 Jun 2019
Amount
Electrical Works
90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
2.2.1 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA, TPMCCB
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
90.12.5.1 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.5.12 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.5.33 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.5.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.5.44 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
90.12.5.45 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.36 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm)
90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.10 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
1.19 : Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.44 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.
90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
od355027/2018_2019 : Flood Light
od355028/2018_2019 : Copper wire No.10 SWG
od355029/2018_2019 : 25 x 3 Sqmm Cu strips
od355030/2018_2019 : Equipotential Bonding rail for heavy duty application
od355031/2018_2019 : 1.25m 14.2mm Maintenance free earthing
od355032/2018_2019 : 3m 20mm Maintenance free earthing
od355033/2018_2019 : Plastic corrossion proofing band
od355034/2018_2019 : Cross connector for 10mm
od355035/2018_2019 : Earthing 10mm Cu bonded steel
od355036/2018_2019 : Supply & Installation of Fixtures <br>Krone in box
od355037/2018_2019 : Supply & Installation of Fixtures <br>300mm sweep exhaust fan
od355038/2018_2019 : Supply & Installation of Fixtures <br>1200mm sweep ceiling fan
od355039/2018_2019 : Supply & Installation of Fixtures <br>18W LED Tube light
od355040/2018_2019 : Supply & Installation of Fixtures <br>Surface LED round light
od355041/2018_2019 : Supply & Installation of Fixtures <br>Bulkhead
od355042/2018_2019 : Supply & Installation of Fixtures <br>Bollard
od355043/2018_2019 : Supply & Installation of Fixtures <br>4M GI post top solar street light
od355044/2018_2019 : Supply & Installation of Fixtures <br>3M GI post top with one light
od355045/2018_2019 : Supply & Installation of Fixtures <br>5M GI pole with dual arm & two lights
od355046/2018_2019 : Supply & Installation of Fixtures <br>5M GI pole with single arm with one light
od355047/2018_2019 : Supply & fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.<br>LAN socket outlet (RJ-45)
od355048/2018_2019 : Supply and fixing of 20mm dia flexible conduit in wall/suspended<br>from ceiling as required.
od355049/2018_2019 : Supplying and making end termination with brass compression<br>gland and aluminium/copper lugs for following size of PVC<br>insulated and PVC sheathed / XLPE cable of 1.1 KV grade as<br>required.
od355050/2018_2019 : Supplying and making end termination with brass compression<br>gland and aluminium/copper lugs for following size of PVC<br>insulated and PVC sheathed / XLPE cable of 1.1 KV grade as<br>required.
od355051/2018_2019 : Supplying and making end termination with brass compression<br>gland and aluminium/copper lugs for following size of PVC<br>insulated and PVC sheathed / XLPE cable of 1.1 KV grade as<br>required.
od355052/2018_2019 : MSB
od355053/2018_2019 : Meter Board<br>
od355054/2018_2019 : Providing and fixing 1/2 HP Motor Pump including material and labour
od369267/2018_2019 : 2 kWP On-Grid Solar Power plant <br>
od369268/2018_2019 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision
od369269/2018_2019 : Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
od369270/2018_2019 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
od369271/2018_2019 : Supply and providing electrical quality rubber Hand gloves suitable for working on 11 kV.
od369272/2018_2019 : Supply and Providing of first aid box with sterile adhesive bandages, cotton, band-aids, anti-septic, lubricant, soap etc. as required.
od369273/2018_2019 : Supply and providing 1.1kV Grade 2M x 1M x 6MM rubber mat as per IS specifications
od369274/2018_2019 : Single arm with one light<br>
od369857/2018_2019 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>8 way (4+24), Double door
od369858/2018_2019 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>6 way (4+18), Double door
od369859/2018_2019 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)<br>4 way (4+12), Double door
D SURESH
Mohan Electricals
Bidder Name
D SURESH
JAYAKUMAR K
Mohan Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_386668.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .