| 1 | L1₹19.7 LAccepted-AOC SAI VILLA C 65 EKTA NAGAR BAREILLY UTTAR PRADESH 243 122 | BAREILLY | UTTAR PRADESH | 243122 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹20.7 L+₹27,455 (1.34%)Rejected-Finance 160 PREM NAGAR BAREILLY | L2 | Rejected-Finance Overall rate are higher than L1 | |
| 3 | L3₹21.4 L+₹1.0 L (4.97%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L3 | Rejected-Finance Overall rate are higher than L1 | |
| 4 | L4₹26.5 L+₹6.1 L (29.8%)Rejected-Finance | L4 | Rejected-Finance Overall rate are higher than L1 | |
| 5 | L5₹26.5 L+₹6.1 L (29.9%)Rejected-Finance | L5 | Rejected-Finance Overall rate are higher than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jan 2020, 6:00 pmClosed
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
REPAIR TO PLASTER FLOORING ROOFING PLINTH PROTECTION ETC IN CERTAIN OTM AND MD ACCN INSTALLATION INCLUDING SEWAGE LINE/SEPTIC TANKS CLEANING AND REPAIR TO MANHOLES SEPTIC TANKS SOAKAGE WELLS INCLUDING CONNECTED WORKS AT MIL STATION BANBASA UNDER GE (
2019_MES_308895_1
8261/BAN/E8
Open Tender
Civil Works
Item Rate
180 days
Banbasa
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹60,000
Yes
21 Mar 2020
23 Dec 2019
17 Jan 2020
23 Dec 2019
16 Jan 2020
6 Jan 2020
23 Dec 2019 - 6 Jan 2020
Amount
DESCRIPTION OF ITEMS
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc and getting out in any type of soil complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick with soil obtained from excavation complete all as secified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as spcecified directed.
Demolition of cement concrete of any description and in any position not, otherwise provided for as in padding over roof slab, roof kers and the like including removing rubbish off the premises complete all as specified and directed.
M & L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) laid over roof slab as in padding and applying 15mm thick palster in cement mortar (1:3) mixed with integral water proofing compound as per manufacturers instructions, finished even and smooth without using extra cement complete all as specified and directed. (Note :- WPC shall be measured and paied seperately)
Supply only integral water proofing compound of approved quality confirming to IS specification complete all as specified and directed.
M & L for cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cills, copings, steps, sesmic and other similar bands, coving, bed, plate and the like including weathering, sightly rounded or chamfered angles and throating complete all as specified and directed.
Demolition of reinforced cement concrete as in manhole covers and the like including removing rubbish off the premises complete all as specified and directed.
M & L for precast reinforced cement concrete (1:2:4) type B1 (Using 20mm graded stone aggrgate) as in landings, cover slabs (for manholes etc), chajas, water troughs mangers, shelves and similar articles with plain faces, set in cement mortar (1:4) complete all as specified and directed. Note: Reinforcement shall be measured and paid saparetly under repective item.
M & L for mild steel TMT bar 10 mm dia & over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia or securig with clips complete all as specified and directed.
Demolition of brick work/stone boulder masonry built in cement mortar including removing rubbish off the premises complete all as specified and directed.
M & L for brick work with old size sub class 'B' bricks in cement mortar (1:6), straight or curved on plan exc 6 m means radius complete all as specified and directed.
M & L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings 15 mm (below or above GL) including removing rubbish off the premises complete all as specified and directed.
M & L for cement concrete in (1:3:6) type C2 (using 40 mm graded sone aggregate) for surface channels, drains etc complete all as specified and directed.
M & L for 100 mm thick cement concrete (1:2:4) type B2 (using 40 mm graded sone aggregate) as in path, hardstanding and the like complete all as specified and directed.
M & L for 75 mm thick cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate) as in plinth protection, path and the like, finished fair and even, laid in panels and filling the joints with mixture of bitumen and sand complete all as specified and directed.
M & L for 40 mm thick cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in flooring, laid in panels, finised even and smooth using extra cement complete all as specified.
M & L for rubber moulded chequred cement concrete tiles 20cmx20cmx25mm thick jointed and pointed neat cement slurry in floors with grey cement no pigment incl 15 mm thick screened bed in CM 1:6 complete all as specified.
S & F 3mm thick glass dividing strips 38 mm wide, fixed in PCC flooring to conform to design complete all as speciified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M & L for glazed ceramic coloured tiles of size 200mm X 300mm X 6 to 7mm thick on vertical surfaces such as skirting, dados etc, laid over and including 10mm thick rendering coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M & L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm as in flooring, laid over and including 15 mm thick screed bed in cement mortar (1:6), set and jointed inculding neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M & L for vitrified ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. laid over and including 15 mm thick screed bed in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
Taking down cement plaster from brick/stone masonry walls/ceilings etc including racking out joints hacking for keys and scrubbing down with water etc complete.
M & L for 15mm thick rendering on fair faces of brick/ concrete surface in CM 1:6 internal walls in patches complete all as specified.
M & L for 15mm thick rendering on fair faces of brick /concrete surface in CM 1:4 external walls in patches complete all as specified.
M & L for 5mm thick rendering on ceiling surfaces in CM 1:3 in patches complete all as specified.
Racking out joints / pointing to brick work in walls or to brick on edge in floors / surface channels etc built in cement or cement lime mortar including raking or cutting out joints and decayed mortar etc, not less than 12mm deep, washing joints, and removing rubbish off the permises complete all as specified and directed.
M & L for flush pointing to brick walls or to brick on edge in floors/pavings in cement mortar (1:4) complete all as specified and directed.
M & L for complete removal of existing decorative treatment and preparing the surfaces of walls by applying 1mm thick of wall putty and applying two coats of oil emulsion distemper over a coat primer complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying 1mm thick wall putty on wall surfaces and applying two coats of oil emulsion paint over a coat of primer complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
S & F in repair 100 mm dia cast iron sand cast soil waste and vent pipes in any length with or without ears, with cement joint laid in trenches or in floors complete all as specified.
S & F in repair 75 mm dia cast iron sand cast soil waste and vent pipes in any length with or without ears, with cement joint laid in trenches or in floors complete all as specified.
S & F in repairs, 110 mm bore PVC (SWR) pipes, single socketed, fixed to walls in any length with rubber ring joints complete all as specified and directed.
S & F in repairs, 110 mm bore PVC (SWR) pipes, single socketed, lalid in trenches or in floors in any length with rubber ring joints complete all as specified.
S & F in repairs, 75 mm bore PVC (SWR) pipes, single socketed, fixed to walls in any length with rubber ring joints complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipes, single socketed, lalid in trenches or in floors in any length with rubber ring joints complete all as specified and directed.
S & F in repairs, PVC pipes 50 mm bore single socketed in any length with rubber ring joints, fixed to wall or in floors including all accessories complete all as specified and directed.
S & F in repairs, 110 mm bore PVC (SWR) bends (any radious), diminising pieces or tapers (large bore measured) all as specified and directed.
S & F in repairs, 75 mm bore PVC (SWR) bends any radious, diminising pieces or tapers (large bore measured) all as specified and directed.
S & F in repairs, 110 mm bore PVC (SWR) junction double (double 'T') equal or unequal with acces door complete all as specified and directed.
S & F in repairs, 110 mm PVC (SWR) WC connector with lip ring complete all as specified and directed.
S & F in repairs, mild steel stack clamps for 100 mm/110mm bore pipe, made out of 50 X 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof complete all as specified and directed.
S & F in repairs, mild steel stack clamps for 75 mm / 50mm bore pipe, made out of 50 X 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to walls or roof complete all as specified and directed.
Dismantling AC coorugated sheets in roof covering complete all as specified and directed.
M & L for AC two piece adjustable plain wing ridge using radious 6mm thick fixed with `L` or `J` hooks complete all as specified and directed. Note: Two pieces adjustable ridges shall be measred as one length.
M & L for 6mm thick asbestos cement corrugated or semi corrugated sheets in roofs, walls etc fixed with `L` or `J` hooks complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 Grade E-165 including notching, drilling, fitting, riveting or welding as required complete all as specified and directed.
S & F 2mm thick Fibre glass reinforced transperent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 pipe section in cement concrete (1:2:4) type B1, smooth finished and reforming benching, including neccesary earthwork as required for 100 mm bore pipe complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 pipe section in cement concrete (1:2:4) type B1, smooth finished and reforming benching including neccesary earthwork as required for 150 mm bore pipe complete all as specified and directed.
S & F in repairs, vitreous china squatting pan "Orissa" pattern of size 580x440 mm, white with integral foot rests excluding flushing cistern with front or back inlet including provision of cement concrete bedding and making good floor including connection to existing trap, flushing pipe complete all as specified and directed.
Supply and fix vitreous chiana wash basin, white, flat back size 550x400mm including cutting for and pinning in ends of brackets or erecting stand but including connection to existing supply, waste pipe and gratings all as specified and as directed.
Supply and fix Vitreous China bowl urinal flat back size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe including connection to existing flushing cistern, flush pipe and waste pipe all as specified and as directed.
Cleaning of blocked floor/nahani trap of kitchen, bathroom, wash hand basin and gullly trap etc up to Ist manhole and disposal of waste materials to a distance n.exc 50 m complete all as specified and directed.
Taking up of existing covers of septic tank of any size and cleaning of same including dewatering and digging out sludge, mud state and removing the sludge to a distance exc 250 m and n.exc 500 m as where directed including cleaning of inlet and outlet pipes and placing the cover in position complete all as specified and directed. Note: Size of tank upto water level shall be measured.
Cleaning of manholes of any size and depth up to 2.00 mtrs under faul condition by removing man hole covers, removing of accumulated liquid, sludge/sediments, transporting the fluid/sludge etc in covered containers and depositing the same out side the camp area/ defence land, cleaning of the manhole with fresh water, placing MH cover back in intact position complete all as specified and directed.
Cleaning of 100mm bore and upto and including 150 mm bore sewage line including manholes and blocked pipe line and disposal of waste materials/spoils up to a distance not exceeding 50 meter by any means complete all as specified. Note relaying/Refixing or S&F of new pipe etc where required shall be measured separately
Cleaning and removing individual blockage in IWC/EWC and removing sludge and foreign materials completely, neatly and making serviceble for free flow all as specified and directed.
Cleaning and removing all scale and dirt etc from tank and mounth of circulating pipe of water storage tank capacity exc 250 litr but not exc 500 litres complete all as specified and directed.
Cleaning and removing all scale and dirt etc from tank and mounth of circulating pipe of water storage tank capacity exc 500 litr but not exc 1000 litres complete all as specified and directed.
M & L for providing and injecting chemical to wall below concrete masonary apron using chemical emmulsion @ 2.25 Ltrs per 1 linear meter including drealing and plastering holes etc in apron complete all as specified and directed. Note: ATT treatment shall be carried out in post construction stage.
M & L for providing and injecting chemical for treatment of soil under existing floors using emulsion @1 ltr per hole 300mm apart including drealing and pluging 12 mm dia holes with cement mortar 1:2 plain ( 1 cenebt : 2 sand) area of floors shall be measurd ) complete all as specified and directed. Note: ATT treatment shall be carried out in post construction stage.
M & L for proviiding and injecting chemical at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 ltrs/hole by drilling 6 mm dia. Hole at diwn ward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed. Note: ATT treatment shall be carried out in post construction stage.
Builders Harpal
R K CONSTRUCTION
URBANS CONSTRUCTIONS
M/s D K Sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .