| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | ₹43.1 L Quoted ₹43.8 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹44.5 LRejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | ₹44.5 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹45.2 LRejected-Finance PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | ₹45.2 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹45.8 LRejected-Finance | ₹45.8 L | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹46.5 LRejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹46.5 L | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | OM ENTERPRISE L13 | m/s prakash enterprise L3 | roxy enterprise L11 | roxy enterprise L11 | SURESH ELECTRICALS L9 | SHREEJI ENTERPRISE L4 | K B N TRADERS L12 | Ravi enterprise L2 | shree chamunda enterprise L8 | SANVI ASSOCIATES L6 | AADESH CONSTRUCTION L10 | VIVEK JITENDRABHAI KATAR L7 | JAY BHARAT METAL SUPPLIERS L5 | BABUBHAI BHIMABHAI PANDAVADRA L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for servicing and overhauling of ACB upto 1600 Amps Capacity including all consumables maintainance kit and required minor parts including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable all as specified and directed by Engineer in Charge. | 1 | Each job | 5,100 ₹5,100 | 4,750 ₹4,750 | 12,000 ₹12,000 | 12,000 ₹12,000 | 30,000 ₹30,000 | 5,250 ₹5,250 | 6,500 ₹6,500 | 18,000 ₹18,000 | 4,520 ₹4,520 | 5,350 ₹5,350 | 5,000 ₹5,000 | 4,510 ₹4,510 | 4,500 ₹4,500 Lowest | 4,800 ₹4,800 |
| 2.00 | S&F in replacement LT volt meter (0-500) digital squire flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete as sepecified and directed by Engr-in-Charge. Make:AE/MECO/Schneider/L&T | 6 | Each | 2,010 ₹12,060 | 1,560 ₹9,360 | 1,600 ₹9,600 | 1,600 ₹9,600 | 2,100 ₹12,600 | 2,350 ₹14,100 | 8,500 ₹51,000 | 1,200 ₹7,200 Lowest | 1,820 ₹10,920 | 2,210 ₹13,260 | 2,000 ₹12,000 | 1,810 ₹10,860 | 1,800 ₹10,800 | 1,600 ₹9,600 |
| 3.00 | S&F in replacement 1100 Volts grade LT Ammeter (0 - 500 A) digital squire flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as sepecified and directed by Engr-in-Charge. Make:AE/MECO/Schneider/L&T | 6 | Each | 1,520 ₹9,120 | 1,430 ₹8,580 | 2,200 ₹13,200 | 2,200 ₹13,200 | 2,300 ₹13,800 | 1,650 ₹9,900 | 3,500 ₹21,000 | 1,200 ₹7,200 | 1,120 ₹6,720 | 1,620 ₹9,720 | 1,500 ₹9,000 | 1,110 ₹6,660 | 1,100 ₹6,600 Lowest | 1,400 ₹8,400 |
| 4.00 | S&F Trip rod of ACB all as specified and directed. | 1 | Each | 1,520 ₹1,520 | 1,275 ₹1,275 | 5,000 ₹5,000 | 5,000 ₹5,000 | 700 ₹700 Lowest | 1,750 ₹1,750 | 1,550 ₹1,550 | 1,450 ₹1,450 | 1,120 ₹1,120 | 1,450 ₹1,450 | 1,500 ₹1,500 | 1,110 ₹1,110 | 1,100 ₹1,100 | 1,200 ₹1,200 |
| 5.00 | S&F Trip Latch of ACB all as specified and directed. | 1 | Each | 710 ₹710 | 640 ₹640 | 6,500 ₹6,500 | 6,500 ₹6,500 | 1,500 ₹1,500 | 750 ₹750 | 1,650 ₹1,650 | 3,500 ₹3,500 | 620 ₹620 | 700 ₹700 | 700 ₹700 | 610 ₹610 | 600 ₹600 Lowest | 600 ₹600 Lowest |
| 6.00 | S&F Door interlock of ACB all as specified and directed. | 1 | Each | 895 ₹895 | 760 ₹760 | 7,200 ₹7,200 | 7,200 ₹7,200 | 1,200 ₹1,200 | 1,025 ₹1,025 | 1,750 ₹1,750 | 2,500 ₹2,500 | 720 ₹720 | 890 ₹890 | 890 ₹890 | 710 ₹710 | 700 ₹700 Lowest | 730 ₹730 |
| 7.00 | S&F Closing coil DC Adaption kit of ACB all as specified and directed. | 1 | Each | 895 ₹895 | 750 ₹750 | 9,000 ₹9,000 | 9,000 ₹9,000 | 1,100 ₹1,100 | 950 ₹950 | 1,850 ₹1,850 | 4,000 ₹4,000 | 720 ₹720 | 890 ₹890 | 890 ₹890 | 710 ₹710 | 700 ₹700 Lowest | 730 ₹730 |
| 8.00 | S&F pole connector kit of ACB all as specified and directed. | 1 | Each | 1,660 ₹1,660 | 1,350 ₹1,350 | 11,500 ₹11,500 | 11,500 ₹11,500 | 1,500 ₹1,500 | 1,750 ₹1,750 | 3,500 ₹3,500 | 9,000 ₹9,000 | 1,640 ₹1,640 | 1,500 ₹1,500 | 1,650 ₹1,650 | 1,630 ₹1,630 | 1,620 ₹1,620 | 1,330 ₹1,330 Lowest |
| 9.00 | Supply and laying of Stone aggregate of size 40 mm /20 mm and laid in 4 pole structure/ DG set location / sub station area and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge | 40 | CUM | 2,050 ₹82,000 | 1,600 ₹64,000 | 1,900 ₹76,000 | 1,900 ₹76,000 | 500 ₹20,000 Lowest | 2,150 ₹86,000 | 750 ₹30,000 | 1,450 ₹58,000 | 1,020 ₹40,800 | 1,810 ₹72,400 | 2,000 ₹80,000 | 1,010 ₹40,400 | 1,000 ₹40,000 | 1,550 ₹62,000 |
| 10.00 | S&F in repair Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with bus bar and one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.
Make: Sintex / National or equivalent model of makes specified. | 45 | Each | 1,150 ₹51,750 | 1,020 ₹45,900 | 1,850 ₹83,250 | 1,850 ₹83,250 | 600 ₹27,000 Lowest | 1,250 ₹56,250 | 6,500 ₹2,92,500 | 1,650 ₹74,250 | 1,020 ₹45,900 | 1,190 ₹53,550 | 1,100 ₹49,500 | 1,010 ₹45,450 | 1,000 ₹45,000 | 1,250 ₹56,250 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
22 May 2026, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
MAINTENANCE/ REPAIR/ REPLACEMENT OF STREET AND SOLAR LIGHT, LIGHT POLES, UG CABLE LINKS, FEEDER PILLAR BOXES, APFC PANELS INCLUDING PREVENTIVE MAINT AND ALLIED WORKS
2026_MES_762861_1
9368/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹88,000
Yes
20 Jul 2026
30 Apr 2026
23 May 2026
30 Apr 2026
22 May 2026
15 May 2026
30 Apr 2026 - 14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for servicing and overhauling of ACB upto 1600 Amps Capacity including all consumables maintainance kit and required minor parts including dismantling the old cable lugs of any size by cutting the cable including fixing of new lugs by pealing the cable all as specified and directed by Engineer in Charge. | 1 | Each job | - | - |
| - | S&F in replacement LT volt meter (0-500) digital squire flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete as sepecified and directed by Engr-in-Charge. Make:AE/MECO/Schneider/L&T | 6 | Each | - | - |
| - | S&F in replacement 1100 Volts grade LT Ammeter (0 - 500 A) digital squire flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as sepecified and directed by Engr-in-Charge. Make:AE/MECO/Schneider/L&T | 6 | Each | - | - |
| - | S&F Trip rod of ACB all as specified and directed. | 1 | Each | - | - |
| - | S&F Trip Latch of ACB all as specified and directed. | 1 | Each | - | - |
| - | S&F Door interlock of ACB all as specified and directed. | 1 | Each | - | - |
| - | S&F Closing coil DC Adaption kit of ACB all as specified and directed. | 1 | Each | - | - |
| - | S&F pole connector kit of ACB all as specified and directed. | 1 | Each | - | - |
| - | Supply and laying of Stone aggregate of size 40 mm /20 mm and laid in 4 pole structure/ DG set location / sub station area and two pole structure including cleaning bushes from grass root and making good surface before laying of stone aggregate complete all as directed by Engg-in-charge | 40 | CUM | - | - |
| - | S&F in repair Hot press moulded SMC junction box 240mm x 130mm x 95mm (inside dimension) fixed with left side hinges and cable terminals with bus bar and one number 6 Amp SP MCB fixed to pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.
Make: Sintex / National or equivalent model of makes specified. | 45 | Each | - | - |
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_854523.xls
BOQ • 0.37 MB
Gen_spec.pdf
Tender Documents • 1.37 MB
Corrigendum1.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].