Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.0 LAccepted-AOC WARD NO 3 SUBHASHPALLY P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹60.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹60.1 LRejected-AOC SUBHASH PALLY WARD NO 3 P O KOKRAJHAR P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM | KOKRAJHAR | ASSAM | 783331 | ₹60.1 L | L2 | Rejected-AOC L2 |
| 3 | L3₹60.2 LRejected-AOC SUBHASH PALLY WARD NO 4 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹60.2 L | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Sajal Sengupta L3 | MRINAL DAS L2 | MANAS DAS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Repairing Works:-
15.28: Dismantling roofing including ridges, hips, valleys and gutters etc, and stacking the material within 50 metres lead of:
15.28.1 G.S. Sheet | 82.32 | Sqm | 144.61 ₹11,904.30 | 144.61 ₹11,904.30 | 144.61 ₹11,904.30 |
| 2.00 | 12.50: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape
wherever required | 82.32 | Sqm | 718 ₹59,105.76 | 718 ₹59,105.76 | 714.06 ₹58,781.42 |
| 3.00 | 12.51: Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 % ) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the steel and polyster top coat 15-18 microns using self drilling/ self tapping screws complete.
12.51.1 Ridges plain (500-600mm) | 8.7 | Rm | 479.12 ₹4,168.34 | 479.12 ₹4,168.34 | 479.12 ₹4,168.34 |
| 4.00 | 9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with bold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately).
9.1.1. Second class teak wood | 0.24 | Cum | 1,39,905.77 ₹33,577.38 | 1,39,905.77 ₹33,577.38 | 1,39,905.77 ₹33,577.38 |
| 5.00 | 9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with bold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately).
9.1.1. Second class teak wood 9.5.1.1 35 mm thick shutters | 11.44 | Sqm | 3,938.94 ₹45,061.47 | 3,938.94 ₹45,061.47 | 3,938.94 ₹45,061.47 |
| 6.00 | 16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete:
16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5. | 53.28 | Sqm | 987.43 ₹52,610.27 | 987.43 ₹52,610.27 | 987.43 ₹52,610.27 |
| 7.00 | 11.5: 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardener compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. | 54 | Sqm | 987.43 ₹53,321.22 | 987.43 ₹53,321.22 | 987.43 ₹53,321.22 |
| 8.00 | 13.5: 15 mm cement plaster on rough side of single or half brick wall of mix:
13.5.1 1:4 (1 cement : 4 coarse sand) | 157.8 | Sqm | 376.94 ₹59,481.13 | 376.94 ₹59,481.13 | 376.94 ₹59,481.13 |
| 9.00 | 13.88: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete | 248.82 | Sqm | 19 ₹4,727.58 | 19 ₹4,727.58 | 17.38 ₹4,324.49 |
| 10.00 | 13.80: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 406.62 | Sqm | 146 ₹59,366.52 | 138 ₹56,113.56 | 136 ₹55,300.32 |
Tender Value
₹56.4 L
EMD Value
₹1.1 L
Closing Date
21 Feb 2026, 12:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Repairing and Renovation of Bhangnamari High School under No.18 Manas Serfang Constituency in Chirang District under Grant No.79. TN_107_11
2026_BTC_50919_1
No.ACE-133/PWD/G.79/2025-26/65
Open Tender
Civil Works - Building
180 days
Kokrajhar
Refer to Tender Documents
4 documents required · 4 mandatory
₹1,200
₹1.1 L
Yes
20 Mar 2026
7 Feb 2026
21 Feb 2026
7 Feb 2026
21 Feb 2026
7 Feb 2026
7 Feb 2026 - 21 Feb 2026
Repairing Works:- 15.28: Dismantling roofing including ridges, hips, valleys and gutters etc, and stacking the material within 50 metres lead of: 15.28.1 G.S. Sheet
12.50: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
12.51: Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 % ) total coated thickness, Zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the steel and polyster top coat 15-18 microns using self drilling/ self tapping screws complete. 12.51.1 Ridges plain (500-600mm)
9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with bold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately). 9.1.1. Second class teak wood
9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with bold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately). 9.1.1. Second class teak wood 9.5.1.1 35 mm thick shutters
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
11.5: 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardener compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
13.5: 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement : 4 coarse sand)
13.88: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
13.80: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.46: Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
12.45: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board
Construction of Boundary Wall:- 2.8: Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. 2.8.1 All kinds of soil
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 4.1.6 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
5.22: Steel reinforcement for RCC work including straightening, leaning, cutting and bending to proper shape palcing in position and binding upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
5.9: Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
5.2: Reinforcement cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillers, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) from natural sources: 3 graded stone aggregate 20mm nominal size derived ffrom natural sorces).
6.13: Half brick masonary with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in uperstructure above plinth level upto floor V level. 6.13.2 Cement mortar 1:4 (1 cement: 4 coarse sand)
13.5: 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement : 4 coarse sand)
13.44: Finishing walls with water proofing cement paint of required shade: 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.46: Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Construction of Community Hall:- 2.6: Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. 2.6.1 All kinds of soil
16.12: Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
4.1: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level : 4.1.6 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
5.22: Steel reinforcement for RCC work including straightening, leaning, cutting and bending to proper shape palcing in position and binding upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
5.22.1 Mild steel and Medium Tensile steel bars.
5.9: Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1. Foundation, footins, bases of columns, etc. for mass concrete.
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts.
5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers.
5.9.3 Suspended floors, roofs, landings, balconies and access platform.
5.1: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources).
6.1: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in; 6.13.1 Cement mortar 1:3 (1 cement : 3 coarse sand)
2.27: Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5.2: Reinforcement cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillers, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) from natural sources: 3 graded stone aggregate 20mm nominal size derived ffrom natural sorces).
4.10: Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
6.13: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)
10.16: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
12.50: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.51: Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.1 Ridges plain (500 - 600mm)
11.4: 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
11.46: Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 11.46.2 Size of Tile 600x600 mm
13.2: 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement : 4 fine sand)
11.46: Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick.
9.1: Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with bold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately). 9.1.1. Second class teak wood
9.7: Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 9.7.1 Second class teak wood
13.26: Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
13.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
13.46: Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
12.45: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.3 12.5 mm thick tapered edge gypsum moisture resistant board
4.17: Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Electrifical Works:- 1.10: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
1.10.2 Group B
1.10.3 Group C
1.12: Wiring for light/power plug point with 2x4.0 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 1no, 4sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.14: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.24: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1. 5/6 amps switch
1.24.3. 15/16 amps switch
1.24.4. 3 pin 5/6 A socket outlet
1.24.5. 6 pin 15/16 A socket outlet
1.27: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.1 1 or 2 Module (75mmX75mm)
1.27.3 4 Module (125mmX75mm)
1.27.4 6 Module (200mmX75mm)
1.27.5 8 Module (125mmX125mm)
1.27.6 12 Module (200mmX150mm)
1.25: Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33: Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.35: Installation,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
2.3.3: Supplying and fixing following, single pole and neural , sheet steel, MCB distribution board, 240V on surface/recess complete with tinned copper busbar, earth, din bar, interconnection, powder painted including earthing etc. as required. (without MCB).
2.10: Supplying and fixing following rating, 240/415V 10KA C curve, MCB suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1. Single pole
2.10.3. Double pole
2.13: Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.2. 63 A TPN MCB
5.2: Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.6: Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7: Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
5.9: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
6.2: Providing and fixing of lighting arrester conductor finial made of 25mm dia 300mm long GI tube having single prong at top with 85mm dia thick GI base plate including holes etc. complete as required.
6.7: Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For horizontal run)
6.8: Providing and fixing GI tape 20mmx3mm thick on parapet or surface of wall for lighting conductor complete as required( For vertical run)
MR-1: Supplying with including fitting fixing of 1200 mm sweep Ceiling fan etc. as directed by the Deptt.
MR-2: Supplying with fitting fixing of 12 W LED Ultra slim ceiling-mounting round LED tune light including all accessories as specified and directed by the deptt. (Orient /Bajaj/Hevells Make) etc.
MR-3: Supplying with fitting fixing of 20W LED tube including all accessories as specified and directed by the deptt. (Orient /Bajaj/Hevells Make) etc.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.48 MB
SBD.pdf
Tender Documents • 3.15 MB
BOQ_81048.xls
BOQ • 0.28 MB
FOB.pdf
Additional Documents • 0.26 MB
Download all tender documents and submit your bid