Infrastructural work at VYBK In Connection with International Football Match to be held between India Vs Brazil------Partly replacement of compound light by LED light fittings VIP Gate to statue of Vivekananda
2026_WBPWD_5019336_1
WBPWD/EE/BED/e-NIQ-90/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
VYBK
Please refer Tender documents.
6 documents required · 6 mandatory
₹18,896
Room No. 108, Purta Bhawan, Salt Lake
20 Aug 2026
20 Aug 2026
31 Aug 2026
20 Aug 2026
28 Aug 2026
21 Aug 2026
21 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | LED Flood Light, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 Hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F. ≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30°-120° as per the application and the project requirement, suitable tiltable fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not be more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape, size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make: Philips/Crompton/Jaquar/Wipro/Havells/ eqv) as per direction of EIC.
70 Watt | 10 | Each | - | - |
| 1.01 | 100 Watt | 20 | Each | - | - |
| 1.02 | 150 Watt | 100 | Each | - | - |
| 2 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 Hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P.F. ≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA Type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not be more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)
(Make: Philips/Crompton/Jaquar/Wipro/Havells/ eqv) as per direction of EIC.
72 Watt | 10 | Each | - | - |
| 2.01 | 150 Watt | 50 | Each | - | - |
| 3 | S & F sheet metal outdoor type Loop box on wall with canopy as rain guard of size 8''x6"x2 1/2" made of 14 SWG CRC Sheet with Hing type door and door locking arrangement incl S&F 250 V, 3 way AC/DC make bakelite terminal & painting of loop box (Make: as per direction of EIC). | 5 | Each | - | - |
| 4 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (Make: Havells/KEI/Polycab/RR Kabel/ eqv) as per direction of EIC. as per direction of EIC.
4 core 16 sqmm | 100 | Meter | - | - |
| 4.01 | 4 core 25 sqmm | 75 | Meter | - | - |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm | 175 | Meter | - | - |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm) | 12 | Meter | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_5091479.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].