Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.3 LAccepted-AOC 11 397 INDUSTRIAL ESTATE WANDOOR ROAD PANDIKKAD MALAPPURAM 676521 | PANDIKKAD | MALAPPURAM | KERALA | 676521 | L1 | Accepted-AOC qualified |
| Sl No | Description | Qty | Unit | YONG INDIA ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00GATE WAY | ||||
| 1.01 | 5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level | 0.32 | M3 | 10,997.08 ₹3,563.05 Lowest |
| 1.02 | 5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 4.32 | M2 | 858.29 ₹3,707.81 Lowest |
| 1.03 | 5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 38.88 | kg | 97.69 ₹3,798.19 Lowest |
| 1.04 | 13.8.2 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1: 4 ( 1 cement : 4 fine sand) | 4.5 | M2 | 432.01 ₹1,944.05 Lowest |
| 1.05 | 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 4.5 | M2 | 134.68 ₹606.06 Lowest |
| 1.06 | 13.45.1 Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm | 4.5 | M2 | 271.39 ₹1,221.26 Lowest |
| 1.07 | 10.16.2 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes | 1,093.93 | kg | 184.2 ₹2,01,502.27 Lowest |
| 1.08 | 13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work | 44.86 | M2 | 221.93 ₹9,955.78 Lowest |
| 1.09 | OD Providing and fixing the main name board of overall dimensions 4.00 metres in length and 0.40 metres in height, fabricated using 30 cm high acrylic letters made from high-quality, UV-resistant acrylic sheet of minimum 3 mm thickness. The letters shall be securely fixed onto a suitably designed and fabricated metal frame using stainless steel studs or other approved fasteners which is measured separately. The name board shall be provided with energy-efficient LED lighting, either as strip or modular lights, to ensure uniform and aesthetically pleasing illumination of the letters, making the signage clearly visible both during day and night. The lighting system shall include waterproof drivers, concealed wiring, and all necessary electrical components conforming to IS standards, with a minimum IP65 rating for outdoor use. The entire unit shall be installed at the specified location using anchor bolts or an approved mounting system, ensuring proper alignment and a neat finish. The rate quoted shall be inclusive of all materials, labour, tools, equipment, transportation, scaffolding, electrical connections, testing, and all other incidental charges required to complete the work to the satisfaction of the Engineer-in-Charge. | 45 | M2 | 14,530.37 ₹6,53,866.65 Lowest |
Tender Value
₹73.5 L
EMD Value
₹50,000
Closing Date
4 Aug 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM(I)
KSIE
Renovation of Bappuji ChildreN Park at Sreekrishnapuram Grama Panchayath, Palakkad District
2025_KSIE_777206_2
CP/INFRA/DTPC/01
Open Tender
Civil Works - Others
Item Rate
120 days
Palakkad
as per tender dcoument
6 documents required · 6 mandatory
₹2,950
₹50,000
14 Aug 2025
28 Jul 2025
6 Aug 2025
28 Jul 2025
4 Aug 2025
28 Jul 2025
Amount
GATE WAY
5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.8.2 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1: 4 ( 1 cement : 4 fine sand)
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.45.1 Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm
10.16.2 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
OD Providing and fixing the main name board of overall dimensions 4.00 metres in length and 0.40 metres in height, fabricated using 30 cm high acrylic letters made from high-quality, UV-resistant acrylic sheet of minimum 3 mm thickness. The letters shall be securely fixed onto a suitably designed and fabricated metal frame using stainless steel studs or other approved fasteners which is measured separately. The name board shall be provided with energy-efficient LED lighting, either as strip or modular lights, to ensure uniform and aesthetically pleasing illumination of the letters, making the signage clearly visible both during day and night. The lighting system shall include waterproof drivers, concealed wiring, and all necessary electrical components conforming to IS standards, with a minimum IP65 rating for outdoor use. The entire unit shall be installed at the specified location using anchor bolts or an approved mounting system, ensuring proper alignment and a neat finish. The rate quoted shall be inclusive of all materials, labour, tools, equipment, transportation, scaffolding, electrical connections, testing, and all other incidental charges required to complete the work to the satisfaction of the Engineer-in-Charge.
NAME BOARD
2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:: Cement mortar 1:6 (1 cement : 6 coarse sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11.56.1 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
13.113.2 Varnishing with varnish of approved brand and manufacture:One or more coats with spar varnish
10.16.2 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels- Granite of any colour and shade - Area of slab upto 0.50 sqm
OD: Supplying and fixing plastic name board of approved size, shape, and shade, including the cost of all materials, labour, conveyance, tools, and equipment, complete as per the direction of the Engineer-in-Charge. The name board shall be fabricated using high-quality, UV-resistant, weatherproof plastic material such as acrylic with a smooth finish and free from sharp edges or defects. The board shall be fixed securely at the designated location using suitable fasteners such as stainless steel screws, wall plugs, or brackets, depending on the mounting surface, ensuring firm alignment and level positioning. The rate shall be inclusive of all associated costs such as transportation, scaffolding (if required), finishing, and any other incidental works necessary to complete the job to the full satisfaction of the Engineer-in-Charge.
REPAIR OF EXISTING OLD BUILDING 1 INCLUDING INDOOR PLAY EQUIPMENT
12.59.1 : Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with. a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
13.60.1: Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
14.85 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
50.9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length using good quality Anjili wood /jack wood
Removing and refixing window shutters after necessary repairs for easy opening and closing, including painting rpelacement of screws etc complete as per the direction of site Engineer-in-charge
13.61.1: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
15.23.1 Dismantling tile work in roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
12.48 Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
OD: Supplying and fixing of Soft Play Equipment for indoor use shall be carried out using high-quality ISI-marked ‘B’ class GI pipes of 14-gauge thickness, ensuring structural stability and durability. The equipment shall include five numbers of raised platforms suitably padded and covered with non-toxic, child-safe materials. A Ball Pool of size 12 ft x 16 ft with 9000 colourful plastic balls, one V-Bridge of 4 ft length, and four punching bags shall be provided for motor-skill enhancement and play interaction. The setup shall include one double slide, one swing unit, a 4 ft-long Time Tunnel, and one Triangle Step element, all securely fixed and padded. A foam pit of size 4 ft x 8 ft filled with 200 soft foam cubes shall be included for safe landings. The play zone will also consist of an 8 ft x 8 ft trampoline with adequate tension and safety netting, an 8 ft x 8 ft wall climber with padded grips, one Rainbow Step, a 3-seater merry-go-round, and a 4 ft Banana Swing. Two units of 3-step climbers and an entry gate of 4 ft x 6 ft shall be installed. Additional features include one roller, four L-Sticke elements, two small triangle obstacles, one 123 seating unit, and all required accessories such as safety nets, base caps, net ropes, decoration windows, bolts & nuts, net caps, EVA (Ethylene Vinyl Acetate) mats, and decorative boards. The scope of work includes complete transportation of materials to site, unloading, on-site assembly, and installation of all equipment, including all necessary labour charges, tools, scaffolding, and fixtures required for proper erection and alignment. All works shall be executed as per approved design, strictly adhering to child safety norms and as directed by the Engineer-in-Charge, ensuring a complete, ready-to-use indoor play area.
EXPANSION/REPAIR OF BUILDING - 2 (THEATRE BUILDING)
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
13.61.1: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.60.1: Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Repair of 12D Theatre: The comprehensive repair and restoration of the 12D cinema system, including the replacement of 2 nos. projector lamps, control panel, computer server, and installation of all required licensed software with keys for seamless operation. The scope also includes servicing of the complete sound system and water special effect units to ensure synchronized audiovisual performance. Additionally, 30 nos. of 3D glasses shall be supplied and integrated for audience use. The work covers the supply, installation, and electrical cabling for effect machines including 2 nos. bubble machines, 1 fog machine, 1 flash light, 1 fire effect machine, and maintenance of the existing air-conditioning system. All components and effects are to be tested and commissioned for full operational efficiency. The quoted rates shall include the cost and conveyance of all materials, tools, labour, and incidental charges required for installation and servicing, and the entire work shall be carried out to the satisfaction and direction of the Engineer-in-Charge.
Supply & Installation of 1.50 ton A/C : :- Supply, installation, testing & commissioning of 1.50 ton Split Air conditioners (Three star & above) suitable for three phase 50Hz, 415 Volts AC supply, indoor & outdoor units with hermetically sealed compressor, air cooled condenser, fully copper based, motor capacitor start run, capacitors relay and over load protector interconnections including special purpose stabilizer and all accessories, copper piping and 2.5Sq.mm 3 core flexible copper cable with thermal insulations, remote control etc as required. (Approved makes : Voltas/ Bluestar/ Samsung/ Hitachi/LG)
PEBBLE WALK
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
13.20 Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 ( 1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 ( 1 cement : 3 fine sand) mixed with 10% finely grounded hydrated line by volume of cement .
OD Providing and laying pebble stones over PCC base in the pathway, including supply of all materials, labour, and execution as per approved specifications. The work includes cleaning the surface of the already laid PCC (Plain Cement Concrete), ensuring it is free from dust, grease, and loose particles. Pebble stones of approved size, shape, and colour shall be laid evenly over the surface, either hand-pressed or gently tapped with a wooden mallet to ensure firm embedding and a uniform level. The rate shall include all materials, tools, equipment, transportation, labour, and incidental charges required to complete the work in all respectsand as direction of the Engineer-in-Charge.
PEBBLE WALK
OD Providing and fixing 12mm laminated glass (Saint Gobain or equivalent) on RCC beam For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %,<br>Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
REPAIR OF PLAY AREA (FLOOR)
15.2.1 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
51.2.4 Filling with Sand - Supplying and filling sand in foundation trenches of culvert for stabilizing the top clay layer including watering, ramming, consolidating and dressing, etc complete for improving bearing capacity of soil.
13.52.2 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
Supplying and fixing 2 seater see saw: The play equipment shall consist of a two-seater see-saw fabricated using a heavy-duty steel structure designed to withstand outdoor conditions and frequent usage. The main frame shall be constructed from powder-coated MS steel sections of adequate thickness to ensure strength, stability, and rust resistance. The seating and handle units shall be ergonomically designed and fabricated using high-quality, weather-resistant, triple-layered Fibre Reinforced Plastic (FRP) components, offering durability, safety, and comfort to children. The pivot assembly shall be fitted with heavy-duty bearings to allow smooth and controlled motion. All edges shall be rounded and surfaces finished to prevent injury. The equipment shall be supplied fully assembled or in kit form with all necessary fasteners, and installed securely on a concrete foundation or as directed by the Engineer-in-Charge. The rate shall include all materials, transportation, labour, and installation charges.
Supply and installation of horse spring rider suitable for children's outdoor play areas. The horse rider body shall be molded from high-quality, weather-resistant, triple-layer Fibre Reinforced Plastic (FRP), designed in an attractive horse shape with smooth, rounded contours for enhanced safety and aesthetics. The supporting spring shall be a heavy-duty, powder-coated steel coil with a minimum thickness of 16 mm, capable of withstanding continuous use and providing balanced, flexible motion. The spring shall be fixed securely to a rust-proof MS steel base plate using industrial-grade bolts and anti-vibration locking nuts. The entire assembly shall be anchored firmly on a concrete base using foundation bolts as per standard installation procedures or as directed by the Engineer-in-Charge. All materials used shall be non-toxic, corrosion-resistant, and painted with lead-free, weatherproof paints. The rate shall include cost and conveyance of all materials, labor charges, installation, and all incidental expenses necessary for the complete and safe functioning of the equipment.
HAND RAILS FOR PEDESTRIAN RAMP
15.2.1 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10.26.3 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
PLUMBING
50.18.8.6.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of EnginOeetrh-ine-CrhEargneg. Cinoneceearleind wgorOk, ringclaudninigscautttiinogncshases and making good the wall etc. 50 mm pipe 6 kg/cm2
50.18.9.7.2 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2
50.18.9.13.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
50.18.8.4.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2
50.18.9.16.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
18.15.2 Providing and fixing brass bib cock of approved quality :20 mm nominal bore
18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
ELECTRIFICATION WORKS
OD: Supply and fixing of outdoor decorative bollard luminaire of 800mm height, having efficacy not less than 70 lumen/watt and power consumption of not less than 8W, complete with integral type driver, closed diffuser and mounted using integral base plate in suitable foundation, complete with all accessories as required. Shall have IP 65 protection.
OD: Supply, conveyance, and installation of 30W LED garden spike lights suitable for uplighting trees and landscape features, complete with all necessary accessories for proper fixing and operation. The light fixture shall have a robust die-cast aluminium housing with corrosion-resistant powder-coated finish, suitable for outdoor use. The luminaire shall be IP65 or higher rated for protection against dust and water ingress, and equipped with a clear, impact-resistant polycarbonate or toughened glass cover. The 30W LED module shall provide focused, high-intensity illumination with a minimum efficacy of 100 lumens per watt, in warm white or cool white colour temperature as specified. The fixture shall include an adjustable spike mount to allow directional aiming for tree uplighting, and be prewired with weatherproof cable for connection to the supply. Installation shall include positioning of the light, secure fixing in the soil or ground surface, wiring through suitable outdoor-rated cables, and testing for proper illumination and safety. All work shall be carried out as per relevant IS standards..(Philips/Luker/Crompton/equivalent)
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
90.4.6 Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
1.47 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
od191777/2024_2025 Supply of 18 W square/round shaped surface mounting LED down lighter : Supply and providing square/round shaped 18 W low glare, surface mounting type, integral LED down light fittings with white powder coated Die cast aluminium body with anodized aluminium reflector etc.as required
od191790/2024_2025 Supply of 1200mm Ceiling Fan : Supply of 1200 mm sweep 5 star rated electric Ceiling Fan, White Colour, capacitor type with double ball bearing, shackles, 300 mm down rod, canopies, blades and resistance type regulator etc. suitable for operation on 220/ 240V, 50 Hz, single phase AC supply etc. as required
od191793/2024_2025 Supply of 20W LED batten/ tube light fittings : Supply and providing 20W Surface mounting type LED lenier batten/ tube light fittings with output of 2000 lumen, with white acrylic cover etc. as required.
od191788/2024_2025 S/F of 400mm Wall Fan : Supply and fixing of 400 mm sweep wall fan with three positions and pulling cords and giving connection etc. as required
od28817/2024_2025 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.1.1 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.37.31 Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 4 sq mm
90.6.5.4 Supply and drawing the following sizes of multi-core PVC insulated&FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
HORTICULTURE
OD Providing and planting Buffalo grass a inside the park, including the cost of all materials, conveyance, labour charges, fertilisers, tools, and equipment, complete as directed by the Engineer-in-Charge. The designated area shall first be cleared of weeds, debris, stones, and unwanted vegetation. The existing soil shall be excavated or loosened to a depth of 10–15 cm, and good quality, fertile topsoil brought from outside shall be spread evenly over the area to improve growing conditions. This imported soil shall be free from stones, clay lumps, and weeds, and shall be mixed with well-decomposed organic manure or compost at the rate of 5–6 kg/sqm; approved fertilisers may be added as specified. Healthy, pest-free Buffalo grass shall be supplied in the form of sods or runners and laid uniformly over the prepared surface with proper alignment, avoiding any gaps or overlaps. Runners, if used, shall be spaced 10–15 cm apart. The laid grass shall be lightly compacted using wooden planks or a light roller to ensure root-soil contact and then thoroughly watered. Regular watering shall be done during the establishment period, and any gaps or dead patches shall be replaced promptly. Movement over the area shall be restricted until the turf is fully established.. The rate shall be inclusive of all operations such as site clearing, supply and transportation of soil and grass, fertilisation, labour, watering, and necessary tools and equipment, etc complete in all respects and as directed by Engineer-in-Charge.
OD: Providing and planting bushy ornamental plants inside the park, including the cost of all materials, conveyance, labour charges, fertilisers, tools, and equipment, complete as directed by the Engineer-in-Charge. The area identified for planting shall be cleared of weeds, debris, and other unwanted materials. Planting pits of suitable size, typically 30x30x30 cm or as specified, shall be excavated at designated intervals. Each pit shall be filled with a well-mixed blend of fertile topsoil (which may be brought from outside if required), well-decomposed organic manure or compost, and approved fertilisers to ensure proper plant nutrition and growth. Healthy, well-branched, disease-free, nursery-grown bushy ornamental plants of the approved variety shall be supplied and carefully planted in the prepared pits. After planting, the soil around the root zone shall be gently compacted to remove air pockets and the plants shall be thoroughly watered. Where required, suitable staking shall be provided to support the plants against wind or mechanical disturbance. The plants shall be regularly watered and maintained during the initial establishment period. The rate shall include the cost of all materials, labour, transportation, tools, staking, watering, and other incidental charges required for the complete and proper execution of the work.
OD: Providing, installing, and commissioning of a sprinkler irrigation system for the park area, ensuring uniform water coverage using a minimum of 6 high-efficiency sprinklers. The scope comprises the supply and conveyance of all required materials such as sprinklers, pipes, fittings, valves, connectors, and other necessary accessories. It also includes complete plumbing work, including excavation, laying of pipelines, fixing of sprinklers, and connection to the water source. All components must be corrosion-resistant and suitable for outdoor use. The system shall be tested and commissioned to ensure proper functioning and coverage. The work shall be carried out in accordance with standard plumbing and irrigation practices, including all labor charges, tools, and incidentals, and completed to the satisfaction and directions of the Engineer at site.
REPAIR OF PAVING
11.19.4 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Ordinary cement without any pigment
Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge
NEW BENCHES AND SEAT
OD Supplying and installatiion in position ,Benches with mild steel frame fabricated from square or rectangular sections (minimum 40 mm x 40 mm x 2 mm thick), hot-dip galvanized and powder-coated to a minimum thickness of 60 microns for enhanced corrosion resistance. The seat and backrest shall be made of high-quality Fiber Reinforced Plastic (FRP) molded sections with smooth, glossy finish, UV resistance, and anti-fade properties. FRP components shall be of minimum 5 mm thickness, ergonomically contoured, and securely fixed to the steel frame using stainless steel (SS304 grade) fasteners with tamper-proof caps. The bench shall be 1500 mm in length, with a seat height of 450 mm and an overall height of approximately 850 mm, providing comfortable back support for parks at various locations including cost,conveyance etc as directed by the Engineer in charge.
COMMON LIGHTING
OD Providing street lighting inside the park, the street lighting system shall consist of energy-efficient LED luminaires mounted on galvanized octagonal poles. The luminaire shall have a die-cast aluminum housing with IP66 protection and IK08 impact resistance, equipped with high-power LEDs having a minimum efficacy of 120 lumens per watt. The LED fitting shall be rated for 230V ±10%, 50 Hz AC supply and conform to BIS and IEC standards. The system wattage shall be 60W/90W (as specified), with a correlated color temperature (CCT) of 5700K (±300K) and a color rendering index (CRI) of ≥70. The driver shall be an integral electronic constant current type with inbuilt surge protection of minimum 10kV. The luminaire shall be mounted on a hot-dip galvanized octagonal pole made of minimum 3 mm thick steel with base plate and foundation bolts. The pole shall include an arm bracket for luminaire mounting, weatherproof cable termination box at the base, and be painted or powder-coated as requiredincluding all cost of Installation including excavation, concrete foundation (1:2:4 mix), and proper earthing using GI earth electrode and copper strip ,conveyance,labour charges etc and as directed by the Engineer in charge.
OD : Providing lighting for statues provided inside the park, the lighting system shall consist of high-efficiency LED luminaires such as floodlights, or spotlights having architectural aesthetics and durable to ensure focused and uniform illumination. The luminaires shall be made of die-cast aluminum housing with a minimum ingress protection of IP66 and impact resistance of IK08, suitable for outdoor installation. Each light shall have a power rating between 20W and 100W depending on required intensity, with beam angles ranging from 15° to 90° for either narrow or wide coverage. The LED lights shall have a color temperature of 3000K (warm white) for aesthetic appeal, or optionally RGB controllable lights for dynamic effects. All lights shall have a color rendering index (CRI) of 80 or above and operate on 220–240V AC, 50 Hz supply, with power factor ≥0.95 and total harmonic distortion ≤10%. The integrated driver shall include minimum 4kV surge protection and optionally support dimming or DMX control. Fixtures shall be mounted using adjustable brackets on poles, pedestals, or ground mounts as needed, with concealed wiring through GI conduits or armored cables and proper earthing using copper earth electrodes including all cost of Installation, a waterproof junction box, timers or smart controllers conveyance,labour charges etc and as directed by the Engineer in charge.
OD: Repairs and commissioning of the existing common lighting system, including replacement of damaged or non-functional fixtures, wiring, switches, and accessories as required to restore full operational condition. The scope includes supply of all necessary materials, tools, and equipment, as well as labor charges for dismantling, installation, testing, and commissioning. The rates quoted shall be inclusive of all costs such as transportation, conveyance, handling, and incidental expenses. All works shall be carried out as per standard electrical engineering practices, safety norms, and to the full satisfaction and directions of the Engineer-in-Charge.
SIGNAGE
OD Providing and fixing neceassary signages using waterproof, full-colour fiberboard of suitable thickness (minimum 5 mm) to ensure durability and resistance to weathering, moisture, and fading. The surface shall feature high-resolution, UV-resistant digital printing with clear pictorial representations and text indicating designated locations, executed as per the instructions and layout approved by the engineer in charge. The colors used shall be vibrant and fade-resistant to maintain visibility over time. All edges of the fiberboard shall be smoothened and sealed to prevent water ingress. The signboards shall be fixed securely at designated locations using stainless steel fasteners or suitable mounting hardware on prepared surfaces or structures, ensuring stable and vandal-resistant installation. Installation shall conform to site-specific requirements and include proper alignment and leveling. The entire work shall comply with relevant safety and quality standards, with the engineer in charge approving the final placement and finish.
GENERAL REPAIRS (COMPOUND WALL)
2.8.1: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:: Cement mortar 1:6 (1 cement : 6 coarse sand)
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.33.1 Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
GENERAL REPAIRS (TREE BASE)
2.8.1: Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels- Granite of any colour and shade - Area of slab upto 0.50 sqm
SCULPTURE/INSTALLATION
OD: Providing and installing in position SCULPTURE of 1.5 m height, proportionally thick carved using high-quality natural stone such as granite or marble, the stone used shall be free from cracks, blemishes, or discolouration, and the finished surface shall be honed or polished as per the approved aesthetic, ensuring clarity in sculptural details and of approved category and size with proper RCC base of approx. 0.6 x 0.6 m, 0.3 m height,including all cost,conveyance,labour charges etc and as directed by the Engineer in charge.
NEW WASTE BINS
OD: Supplying and installatiion of 60 to 80 Litre capacity animel shaped waste bins made of FRP at various locations,including cost,conveyance etc as directed by the Engineer in charge.
CCTV CAMERA/SECURITY SYSTEM (Providing and installing CCTV Camera security system and all other connected accessories)
Supplying and installing 4 MP Dome/Bullet Camera with EXIR 2.0, IP67, IR Range 50 . MAKE: Dahua/cp plus or Equivalent
Supplying and installing 32-Channel NVR with PoE Support and HDMI output. MAKE: Dahua/Hikvision or Equivalent
Supplying and installing 8 TB Surveillance Hard Disk (SATA)
Supplying and installing - SMPS 12V/10A Power Supply
Supplying and installing- Desktop Switch – 24 Port (PoE or with splitters as applicable)
Supplying and installing- HDMI Extender (for long monitor cable runs)
Supplying and installing - Wireless Mouse (USB Optical)
Supplying and installing - Spike Buster / Surge Protector (4 Sockets)
Supplying and installing - PVC Junction Boxes (4x4)
Supplying and installing- PoE Connectors / RJ45 Jacks
Supplying and laying Cat-6 Cable with casing/conduit
Supplying and installing - LED Monitor 24" for Live Viewing
Servicing of exisitng IP Bullet camera CCTV Camera security system and all other connected accessories
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .