Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC NOUSHAD MANZIL PIRAPPANCODE PIRAPPANCODE P O 695607 | THIRUVANANTHAPURAM | KERALA | 695607 | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.7 L+₹2.7 L (7.18%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical KOTHENALLOOR KAKKADA P O THIRUVANANTHAPURAM 695505 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695505 | - | Rejected-Technical L3 |
Tender Value
₹42.0 L
EMD Value
₹50,000
Closing Date
15 Nov 2019, 6:00 pmClosed
EE, LSGD Division, Thiruvananthapuram D P, Pattom
O/o the EE, LSGD Division, Thiruvananthapuram D P, Pattom, Pin -695004
Please refer tender documents
2019_LSGD_318439_1
e-15/EE/LSGD/2019-20/swaraj
Open Tender
Civil Works - Buildings
Item Rate
180 days
Nanthancode
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
Yes
online
₹50,000
Yes
3 Jan 2020
7 Nov 2019
18 Nov 2019
7 Nov 2019
15 Nov 2019
7 Nov 2019
Amount
DEMOLOSHING WORK
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
15.7.1 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar
50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
WALL CLADDING AND ACOUSTIC TREATMENT
od337781/2019_2020 : Providing and fixing specified wood frame work consisting of battens 50x25 mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete using Anjili wood scantlings [modified item of 9.36.1]
9.32 : Providing 50x50x50 mm 2nd class teak wood plugs including cutting brick work and fixing in cement mortar 1:3 ( 1 cement : 3 fine sand) and making good the walls etc.
12.62 : Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183, having density 49 Kg/m3, 50mm thick, wrapped in 200 G Virgin Polythene Bags fixed to wall with screw, rowel plug & washers and held and in position by criss crossing GI wire etc. complete as per directions of Engineer-in-charge.
od341800/2019_2020 : Providing and fixing in stepped and profiled wall ling with 12 mm thick marine grade plywood over the existing wooden frame work and providing decorative veneer facing of approved manufacture with 4 mm thick plywood one side decorative veneer conforming to IS:1328(type1) for stepped/profiled lining / cladding with necessary screws, including priming coat on unexposed surface with: , including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete: [Modified item of 9.35.2 and 9.37]
od344868/2019_2020 : Providing & Installing of fire retardent Fabric finished Wall Panel having minimum 40 mm thick High density rock wool with natural square edge (Size: 600*600 minimum or as approved), installed with concealed grid Hook on system and demountable panels. Wall brackets 50*50*75 mm & 2.8 mm thick shall be installed @ 1200 mm c/c for installation of panels. Panels shall be manufactured from High density glass wool with visible surface as a glass fiber fabric and the back of the tile covered with glass tissue. The rock wool core of the tiles shall be tested and classified as non combustible according to prEN ISO 1182. The system should have Sound Absorption NRC value of 0.9 (according to EN ISO 11654). Tiles should withstand a permanent ambient RH Upto 95% at 30*C without sagging, warping or delaminating (ISO 4611).
FALSE CEILING
12.45.2 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum fire resistant board conforming to IS; 2095-Part I
od345179/2019_2020 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:<br>12.5 mm thick tapered edge gypsum fire resistant board conforming to IS; 2095-Part I
12.52.4 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.
PROVIDING DOUBLE GLAZED WINDOW UNITS (SOUND PROOF)
od343754/2019_2020 : Providing and fixing Double Glazed Unit (6mm thick ST161 Sparkling Eyes- windows sound proofing) consisting of double skin with 6 mm thick plane glass with 12 mm vacuum space inside and hermetically sealed at edges including cost of all materials, labour charges, conveyance, loading and unloading charges, including providing frame work all round the glass panels.
PAINTING
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od343898/2019_2020 : Polishing the veneered surface and wooden doors with two coat of melamaine polish over two coat of sealer applied coat by coat with proper grade of sanding in between the sealer coats including the cost of sanding the substrate surface with appropriate grade of Sand paper ( No 80 for ordinary surfaces and No 120 for very smooth surface), filling the undulations with a mixture of filling powder, sealer and glue including the cost of all materials, labour charges etc complete [Modified item No. 14.70]
9.40.1.2 : Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete:2nd class teak wood50 x 20 mm
FALSE FLOORING AND FLOORING
11.47.4 : Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1000x1000 mm
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
od343909/2019_2020 : Supplying and fixing in position 25 mm thick maraine grade water resistant plywood 710 grade conforming to IS: 5509 on the existing MS fame work using auto locking steel screws including cost of all materials, labour charges etc complete. (modified 11.33.1)
od156405/2019_2020 : Wooden laminate flooring at all heights conforming to the norms of European Standard Pr EN-13329 shall be minimum 8mm thick consisting of a high density fibre board (HDF) core with a design layer on top protected by a highwear and scratch resistant overlay, and a melamine backing at the bottom with the quality of Direct Pressure Laminate (DPL)
ACOUSTICAL DOORS AND VERTICAL BILNDS
od156404/2019_2020 : Acoustic Door : Providing and fixing of teakwood door 75mm (nominal) along with fire and smoke Intumescent seal strip of size 12mm x 4mm for 120 minutes fire rated and Rw rating acoustic door with minimum 75mm thickness having infill of 45mm thick resin bonded fibreglass of 48 kg/m3 density sandwiched by two 12mm thick non- combustible fire rated boards (edge to edge on internal hardwood frame) and cladded with 6mm thick commercial ply facing and 3mm sheet rubber interlayer and finished with 1mm thick laminate/as per architect. All material to be approved by the Acoustic Consultant prior to installation. The board shall be Resistant to vermin, mould growth, minor impact, abrasion and short term water attack and shall be off-white in color with a smooth surface suitable to receive most forms of decoration. Should include door closer, coordinator, Panic Bar, 5? Ball Bearing Hinges(SS) (4 nos. for each leaf of door) and Door Handle as per architect both for single and double doors. The door shall be finished with two coat of polyeurethne over appropriate coat of sealer, filler etc with apprpriate grade of sanding.
od165133/2019_2020 : Supply and fixing of 100mm thick vertical blinds (fabric) PARRYTEX or WINDOW FASHIONS brand or approved equivalent) for windows
LEAK ARRESTING WORKS ON THE SHEET ROOF
12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)
od345026/2019_2020 : Engaging Fitter for sealing the fake holes seen in the roofing sheet to arrest the rain water sweeping inside.
od345021/2019_2020 : Engaging man coolie for sealing the fake holes seen in the roofing sheet to arrest the rain water sweeping inside.
od345063/2019_2020 : Providing and arranging individual scaffolding system (Single Unit) for any height in the Sixth floor of Swarajbhavan Building (Modified Item of 14.72X)
ELECTRIFICATION AND AIRCONDITIONING-TO BE EXECUTED, SUPERVISED AND BILLED BY THE ELECTRICAL WING, LSGD DIVISION, THIRUVANANTHAPURAM.
od365755/2019_2020 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 14SWG Copper earth wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. <br>Single control light point with 6A, 3 plate ceiling rose-Single control light point with 6A, 3 plate ceiling rose
od365797/2019_2020 : Supply and fixing Computer point including supply ang fitting 3 sets of 6A modular type plug socket 5 pin with 6A modular type SP control switches on suitable size MS metal box ( Group B) as per PWD specification
od366131/2019_2020 : Supply and providing 6/16 A modular type power plug socket controlled with 16 A modular type switch mounted on suitable factory built MS box with earthing facility, giving interconnection etc as required
od366134/2019_2020 : Supply, conveyance installation testing and commissioning of architectural led luminaire provides soft-light and glare free symmetrical illumination with prewired light fitting having >100 lm/W lamp efficiency, colour temperature of 5700 K and 4000 lumen output (HAVELLS CONSTA LED Consta1144lP40Wled857sPmmaWH or equivalent PWD Approved make.)<br>40 W LED Fitting-1200 mm
od366138/2019_2020 : Supply and installation of 15 W LED 3000 K -6500 K 150 lumens per watt, IP 53, 215 mm dia recess mounted down lighter with electronic driver complete as required with 5 years warranty ( Corvi Flat 8 or PWD approved make with equivalent specification )
od366140/2019_2020 : Supply and installation of 10W LED 5700 K -6500 K wall / ceiling mounted bulk head fitting with built in electronic driver complete as required luker / havells / Crompton / Philips
od366143/2019_2020 : Supply and installation of 36 W LED 5700 K -6500 K 150 lumens per watt, IP 54, 600 x 600 mm recess mounted down lighter with electronic driver complete as required with 5 years warranty ( Corvi LED or PWD approved make with equivalent specification )
od366148/2019_2020 : Supply and fixing of 50 W LED Strip 3000 K -6500 K 900 lumens per metre 5 m long with electronic driver comptible for with 1 years warranty (Philips Linea Plus 31400 or PWD approved make with equivalent specification )
od366152/2019_2020 : Supply, conveyance, installation, testing and commissioning wall mounting fan of the following sizes using mounting brackets supplied along with the fan and giving connection with existing wire.<br>400 mm sweep
od366156/2019_2020 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - double cover TPN Vertical DB with provision for fixing MCCB as incomer and SP / TP MCB as outgoing (IP 42/43)
od366162/2019_2020 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8 + 12 ) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator /RCCB / RCBO as incomer and SP / TP MCB as outgoing (IP 42/43)
od366165/2019_2020 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover ( IP 42/43)
od366175/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 25A, 4 pole, 30 mA RCCB
od366177/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 25 A four pole mini break isolator
od366183/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 40A, 4 pole, 30 mA RCCB
od366186/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 40 A four pole mini break isolator
od366191/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 63A, 4 pole, 100 mA RCCB
od366195/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 63 A four pole mini break isolator
od366196/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 63 A, 10kA, 3 pole MCB
od366198/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 40A,10kA,TP MCB ( C curve)
od366200/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 25A,10kA,TP MCB ( C curve)
od366205/2019_2020 : Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 6A - 32 A,10kA,SP MCB ( C curve)
od366210/2019_2020 : Supply and fixing 160A, 25/35kA (Ics=100 % Icu), 4 pole current limiting type MCCB with microprocessor based release with thermal setting of 50- 100% having adjustable OL & SC
od367178/2019_2020 : Duct work complete with angle iron flanges, Hi Tech GI supports, GI rods, anchor bolts, GI nut & bolts, PVC / Rubber gaskets complete with all fittings, bends, transformations, vanes, splitter dampers, inspection dooors, plenums etc. as required<br>22 gauge GSS ducting
od367179/2019_2020 : Duct work complete with angle iron flanges, Hi Tech GI supports, GI rods, anchor bolts, GI nut & bolts, PVC / Rubber gaskets complete with all fittings, bends, transformations, vanes, splitter dampers, inspection dooors, plenums etc. as required<br>24 gauge GSS ducting
od367180/2019_2020 : Supply and istallation of class 1 type Nitrile Rubber 10 mm open cell elastomeric insulation for Accoustic Insulation of Ducts.
od367181/2019_2020 : Supply and istallation of class O type Nitrile Rubber 9 mm open cell elastomeric insulation for Thermal Insulation of Ducts.
od367182/2019_2020 : Supply and fixing of powder coated extruded aluminium Air gills without collar damper as per specifications
od367183/2019_2020 : Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories in recess including cutting the wall and making good the damages etc as required.<br>20 mm dia light gauge
od367184/2019_2020 : Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including cutting the wall and making good the damages etc as required.<br>20 mm dia light gauge
od367185/2019_2020 : Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including cutting the wall and making good the damages etc as required.<br>25 mm dia light gauge
od367186/2019_2020 : Supply, laying and clamping of 1 no. PVC insulated and PVC<br>sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60 cms, making good the damages, colour washing etc. as required.<br>3.5 core 70 sqmm with factory made clamp
od367187/2019_2020 : Supplying siemens / tropodur type nickel plated double<br>compression brass cable gland for PVC insulated and PVC<br>sheathed armoured aluminium/ copper conductor cable 1.1 KV<br>grade, and making end termination suitable for 2/ 3/ 3½/ 4 core<br>cable of the following sizes as required.<br>70 sqmm
od367188/2019_2020 : Supply of superior quality aluminium tubular cable socket and<br>making core termination of cables of the following sizes including crimping etc. as required<br>70 sqmm
od367189/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>1 sq mm 2 run
od367190/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>1.5 sq mm 3 run
od367191/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>2.5 sq mm 3 run
od367192/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>4 sq mm 4 run
od367193/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>4 sq mm 2 run
od367194/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>2.5 sq mm 1 run
od367195/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>6 sq mm 4 run
od367196/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>4 sq mm 1 run
od367197/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>16 sq mm 4 run
od367198/2019_2020 : Supply and drawing 650/100 V grade PVC insulated stranded<br>single core copper conductor cables conforming to IS 694 Part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.<br>10sq mm 1 run
od367199/2019_2020 : Supply & fixing the following types of boxes suitable for modular accessories in surface/recess including making good the damages,colour washing etc as required.(Group B/RoHS compliant)<br>9 module metal box in recess
od367200/2019_2020 : Supply & fixing the following types of boxes suitable for modular accessories in surface/recess including making good the damages,colour washing etc as required.(Group B/RoHS compliant)<br>8 module metal box in recess
od367201/2019_2020 : Supply & fixing the following types of boxes suitable for modular accessories in surface/recess including making good the damages,colour washing etc as required.(Group B/RoHS compliant)<br>1 / 2 module metal box in recess
od367202/2019_2020 : Supply & fixing the following types of front plates on the existing modular boxes.(Group B/RoHS compliant)<br>9 module white/off-white
od367203/2019_2020 : Supply & fixing the following types of front plates on the existing modular boxes.(Group B/RoHS compliant)<br><br>8 module white/off-white
od367204/2019_2020 : Supply & fixing the following types of front plates on the existing modular boxes.(Group B/RoHS compliant)<br><br>1 / 2 module white/off-white
od367205/2019_2020 : Supply and fixing the following modular switches and accessories in the existing front plates and giving necessary connections as required(Group B/RoHS compliant)<br>1000 W Dimmer - 2 Module
od367206/2019_2020 : Supply and fixing the following modular switches and accessories in the existing front plates and giving necessary connections as required(Group B/RoHS compliant)<br><br>16 A SP 1 way Switch
od367207/2019_2020 : Supply and fixing the following modular switches and accessories in the existing front plates and giving necessary connections as required(Group B/RoHS compliant)<br>16 A SP 2 way Switch
od367208/2019_2020 : Supply and providing plate earthing as per IS 3043 with 600 x 600 x 6.30 mm GI/CI earth plate 20 mm GI watering pipe fixed to erath plate with 20 x 3 mm GI clamps.GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concerte of 1:4:8 PCC using 40 mm broken stone (10 cm thick),brick work in cement mortear 1:6 plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4,12mm thick(the finished inside dimension shall be 300x300x300 mm) but excluding test joint, earth continuty conductor to the plate,and covering at the top. ( in ordinary soil )
od367209/2019_2020 : Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required <br>300 x 300 x 6 mm cast iron gully trap with covering
od367210/2019_2020 : Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.<br><br>2 x 25 x 3 mm GI strip
od367211/2019_2020 : Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.<br>3.15 mm bare copper conductor (10 SWG)
od367212/2019_2020 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.<br>3.15 mm copper conductor (10 SWG)
od367213/2019_2020 : Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).<br><br>3.15 mm copper conductor (10 SWG)
od367214/2019_2020 : supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.<br>3.15 mm (10 SWG)
od367215/2019_2020 : Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required<br><br>25 x 3mm brass bolt & nut
PR Constructions
A ONE AGENCIES
Bidder Name
NOUSHAD.B
PR Constructions
A ONE AGENCIES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_439297.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .