Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical C 103 UGATI HEIGHTS NR SWAGAT RAINFOREST 1 KUDASAN POR RAO KUDASAN GANDHINAAGR 382421 GUJARAT | AHMADABAD | GUJARAT | 382421 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹9.5 L
EMD Value
₹19,040
Closing Date
27 Aug 2026, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LABORATORY JODHPUR
REPAIR AND MAINT OF EOT CRANE, FIRE ALARM AND DETECTION SYSTEM IN TECHNICAL AREA DEF LAB JODHPUR
2026_MES_782439_1
8760/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,040
Yes
29 Aug 2026
3 Aug 2026
29 Aug 2026
3 Aug 2026
27 Aug 2026
19 Aug 2026
4 Aug 2026 - 18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation,commissioning and testing for replacement of repeater panel of 12 zonal fire alarm panel confirming to IS 2119 and totally enclosed dust and vermin proof and shall be completely solid state design on wall /floor mounting made out of 16 gauge(1.6mm thick) MS sheet& MS frame as per existing make consist of followoing :
(a) Visual and audio indication of fire for each zone indpendently. (b) Provision to sound all the sirens when fire breake out. (c ) Visual indication for clear healthy & fault less circuit
(d) Facility to indicate failure of indicating lamps of the circuit by visual & audio alarm different from fire alarm.(e) Battery unit of supply 24 volts DC to system with acumulator of suitable capacity and automatic charging arrangement on AC and complete with Voltmeter and Ammetter etc of suitable ranges and battery charger (02 Nos of battery of 12volt 7 AH) complete all as specified and directed by engineer-in- charge
Make :- Honeywell, Agni, GST, Morley, Edward (Edward-Honeywell), Notifier, Bosch, Fire Lite, Simplex, and Ravel. | 1 | Each | - | - |
| 2 | All as per item No 01 but 08 Zonal fire alarm panel as per existing make at site including complete connections with master control panel all as specified and directed by engr-in-charge. | 1 | Each | - | - |
| 3 | All as per item No 01 but 4 Zonal fire alarm panel as per esisting make at site including complete connections with master control panel all as specified and directed by engr-in-charge. | 2 | Each | - | - |
| 4 | All as per item No 01 but 2 Zonal fire alarm panel as per esisting make at site including complete connections with master control panel all as specified and directed by engr-in-charge. | 2 | Each | - | - |
| 5 | M&L for replacement of single run of PVC FRLS insulated 1100Volt grade rounded twin core sheathed copper conductor of size 1.5 sqmm drawn through with rigid PVC conduit of 25mm dia fixed on wall /ceiling, 0.75mm dia copper earth continuity conductor to common earth and connected earth dolly including connecting with ionisation type smoke detector and fire alarm junction box complete with testing after the connection has made all as per specified and directed by Engineer-in-charge. Note- PVC conduit shall be measured and paid separately. | 200 | RM | - | - |
| 6 | Supply and fixing in replacment of Rigid non metallic PVC conduict exclusive of boxes but included of all tees, bends,elbow, reducers, bell mouth tubes ends and fixing accessories such as couplers lock nuts saddles pipe hooks etc of 25mm dia all as specified and directed by engr-in charge. | 150 | RM | - | - |
| 7 | Supply and fixing in replacement dual smoke detector of solid state design with dual ionisation chamber solid radio active sense response indicator lamps mounting base and Junction box for fixing etc completed all as specified and directed by engr-in-charge. Make :- Apollo, Siemens, GST, Honeywell | 60 | Each | - | - |
| 8 | Supply and fixing in replacement conventional type multisensor detector with heat and smoke combination including indicator lamps mounting base and Junction box for fixing etc all as specified and directed by engineer-in-charge. | 15 | Each | - | - |
| 9 | S&F in replacement Response Indicator unit of size 90mmx65mmx50mm all as specified and directed by engr-in-charge. | 30 | Each | - | - |
| 10 | S&F in replacement Manual call point(resettable type) 145mmx90mmx50mm all as specified and directed by engr-in-charge. | 15 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
PS.pdf
Tender Documents • 1.16 MB
BOQ_876613.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .