| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.2 LAdmitted-Finance | -17.86% | ₹2.2 L | L1 | Admitted-Finance |
| 2 | L2₹2.6 LAdmitted-Finance | -2.10% | ₹2.6 L | L2 | Admitted-Finance |
Tender Value
₹2.6 L
EMD Value
₹5,280
Closing Date
7 May 2026, 6:00 pmClosed
Executive Engineer PWD Electrical Div. Ist Jodhpur
Executive Engineer PWD Electrical Div. Ist Jodhpur
Repair servicing and maintenance of coolers work for PWD campus Jodhpur
2026_CEPWD_555878_6
NIT No.04/2026-27 of EE PWD Elect.Dn.I Jodhpur
Open Tender
Electrical Works
330 days
Executive Engineer PWD Electrical Div. Ist Jodhpur
Please refer Tender documents
3 documents required · 3 mandatory
₹500
Secretary, RREIS Executive Engineer PWD Electrica
₹5,280
Yes
Executive Engineer PWD Electrical Div. Ist Jodhpur
12 May 2026
4 May 2026
8 May 2026
4 May 2026
7 May 2026
4 May 2026
5 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. | - | - | - | - |
| 2 | Un Armoured | - | - | - | - |
| 3 | 2 core x 2.5 Sq.mm | 60 | mtr | 105 | ₹6,300 |
| 4 | Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. | - | - | - | - |
| 5 | 0.80mm | 5 | Sq Mtr | 1,093 | ₹5,465 |
| 6 | 1.00mm | 5 | Sq Mtr | 1,283 | ₹6,415 |
| 7 | 1.25mm | 5 | Sq Mtr | 1,514 | ₹7,570 |
| 8 | Supply and Fixing of Desert Cooler having cooling capacity of 5000 cum/hr., approx. size of cooler is 28"x28"x38" and having tank of 9" height with 20" 1400 rpm heavy duty fan motor and required size of submersible pump and all other required accessories. Cooler should be made of 18 SWG GI sheet for tank and remaining cooler body should be of 20 SWG GI sheet, grill of size 22"x25" including required size angle iron stand duly painted with 2 coats of red oxide and one coat of enamel paint complete in all respect as required. | 8 | Each | 12,688 | ₹1,01,504 |
| 9 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . | 50 | Kg | 114 | ₹5,700 |
| 10 | P & F 3 Speed rotary switch for Desert Cooler complete with testing etc as required. | 15 | Each | 74 | ₹1,110 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tendernotice_2.pdf
PDF • 0.28 MB
Tendernotice_3.pdf
PDF • 1.91 MB
BOQ_989965.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid