| 1 | L1₹20.2 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹23.0 L+₹1.4 L (6.33%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹23.9 L+₹2.2 L (10.4%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹25.2 L+₹3.6 L (16.5%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹26.4 L+₹4.8 L (22.0%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
31 Dec 2019, 6:00 pmClosed
GE Chandigarh
GE Chandigarh
REPAIR AND REPLACEMENT OF INTERNAL WIRING ITEMS, FITTINGS, FIXTURES AND CERTAIN OTHER CONNECTED ITEMS AT TRANSIT CAMP HALLOMAJRA UNDER GE CHANDIGARH.
2019_MES_298531_1
GE/CHD-66/2019-20
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class D Cat b i
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹72,000
Yes
28 Feb 2020
16 Nov 2019
2 Jan 2020
17 Nov 2019
31 Dec 2019
6 Dec 2019
17 Nov 2019 - 23 Nov 2019
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
Taking down carefully old unsv copper/aluminium sub main wiring iny size any description and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete, all as specified & directed.
Taking down carefully old unsv MCD DBs ay type and description incl MCBs and depositing into MES store yard for ruse or issue under sch of credit complete
M&L Point wiring with 1.5 sq mm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable in and including concealed , non metalic rigid pvc medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unseathed FRLS cable of size 1.5 sq mm copper conductor as earth wire to common earth dolly including concealed in wall/ceiling, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switches, sockets, fan regulator etc for One light/fan point controlled by one way switch 6 amps 240 volts : Note:-1. Colour code of wiring should be (for phase -Red, Neutral-black & earth wire green) 2. Modular switch sockets fan regulators shall be meaured and paid separately udner respective items. 3. Cost of mudular MS box , modular cover plate an frame of any modules as required at site and as directed by Engineer-in-charge is deemed to be included in th quoted rates.
All as per item No 4 above but one fan point controlled by one switch and one regulator.
All as per item No 4 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 4 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 4 above but one call bell point controlled by one way bell push switch
All as per item No 4 above but one light point controlled by two way switch
All as per item ser no 4 herein before but wiring with 2.5 sqmm copper conductor for power point
Point wiring for one light point/fan point controlled by one switch with 1.5 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.00 Sqmm PVC insulated unsheathed copper conductor single core multi strand flexible and 1.00 sqmm PVC insulated unsheathed copper conductor single core cable (green colour as earth lead in and including concealed non metallic rigid PVC conduit medium grade with all fittings (ISI marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, iuncluding cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per item ser No 11 above but point wiring for one fan point
All as per item No 11 above but one 3 pin 6 Amps switch socket out let point on independent board
All as per item No 11 above but one 3 pin 6 Amps switch socket out let point on same board
All as per item No 11 above but one call bell point controlled by one way bell push switch
All as per item No 11 above but one light point controlled by two way switch
All as per item ser no 11 herein before but wiring with 2.5 sqmm copper conductor for power point
S&F modular one way switch 6 Amp 240 volte suitable for one model etc complete as specified and directed.Make : Anchor - Anchor - Panasonic vision/Indoasian - ELVIRA//Havells - Pearlz/Anchor
S&F modular socket shutter suitable for 6 Amp 2/3 pin combined 250 volts complete as per specified and directed Make : Anchor - Panasonic vision/Indoasian - ELVIRA//Havells - Pearlz/Anchor
S&F modular switches suitable for 16 Amp 240 volts complete as specified and directed Make : Anchor - Panasonic vision/Indoasian - ELVIRA//Havells - Pearlz/Anchor
S&F modular socket shutter suitable for 16 Amp 2/3 pin combined 250 volts complete as specified and directed. Make : Anchor - Panasonic vision/Indoasian - ELVIRA//Havells - Pearlz/Anchor
S&F modular step type fan regulator suitable for 120 watt 250 volts complete all as specifed and directed Make : Anchor - Panasonic vision/Indoasian - ELVIRA//Havells - Pearlz/Anchor
S&F modular bell push switch 6 Amp 240 volte suitable for one model etc complete as specified and directed.Make : Anchor - Panasonic vision/Indoasian - ELVIRA//Havells - Pearlz/Anchor
S&F in repair switch piano flush type single pole one way 6 Amp 240 volte complete as specified and directed
S&F in repair socket shutter 5 pin 6 amps flush type 250 volts complete all as specified and as directed
S&F switches piano flush type 16 Amp 240 volts complete as specified and as directed .
S&F socket shutter suitable for 16 Amp 2/3 pin combined 250 volts complete as specified and directed.
S&F step type fan regulator suitable for 120 watt 250 volts complete all as specifed and directed
S&F switch two way 6 Amp 240 volte suitable for one model etc complete as specified and directed.
S&F bell push switch 6 Amp 240 volt piano type .
M&L for call bell ding dong AC 230 Volts single pole etc complete as specified and directed
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed
S&F lamp holder pvc/polycarbonate type with back plate suitable for batten fitting complete as specified and directed
Supply only LED lamp 9/10 watt (cool white)retrofit B 22 with polycarbonate body. (Cool while)
Supply only LED lamp 12 watt (cool white) retrofit B-22 with polycorbonate body.
Supply only LED retrofit INVERTER lamp 9W with 04 hrs back up time, Cool white, (lumen output not less than 900 lumens) at main supply and 450 lumns at backup , CRI more than 80,operating voltage 230 V AC 50 HZ , opeating temperature (-10⁰ C to +50⁰C), glare free, 0 UV radiation all as specefied and directed.
Supply only LED lamp screw type (Thread type) 8 watts (cool white)
Supply only LED 18/20 watt (Retrofit) tube light 4 feet size (Warm white) double capped with polycorbonate body and aluminium heat sink system wattage not more than 20 watt, with surge protection device min 2 kv, CRI more than 80, glare free, power factor more than 0.9 and connection. Cat No BLRB 18 W CWC of make Bajaj or equivalent as approved by GE.
S&F in repair decorative box type fitting with blue colour end cap for LED tube 16/18 watt luminaire for 230 volt AC incl LED tube 16 watt with inbuilt surge protection device complete all as specified & approved by GE.
S&F in repair LED tube light decorative box type fitting TRIMLINE type complete with LED tube 36 Watts , 5700K integrated LED batten with inbuilt surge protection device
S&F in repairs energy saving new generation 10 W LED IP 65 bulkhead luminaire with opal diffuser with 10 watt LED lamp incl 3 core flexible cord from ceiling rose to connector of fitting etc complete as specified and directed
S&F surface mounted round type energy saving ceiling mounted decorative LED 8 watt luminair luminair with opal diffuser for soft light with suitable size driver incl 3 core cable from ceiling rose to connector of fitting etc complete as specified and directed
S&F mirror light sleek LED mirror light provided with high output diffuser with suitable capacity driver with all comptonants as per manufacturer with 3 core flexible cord from ceiling rose to connector of fitting etc complete as specified and directed
S&F in repair Recess mounting LED 2x2 feet luminaire 36 watts with white acrylic drop light dissipator with white powder coated CRCA housing with and including LEDs fixed to the housing . Convex acrylic diffuser lumen output not less than 3600 CRI more than 70 PF - 0.9 suge protetion upto 1 KV complete Make : Havells/Cromption/Halonix/C&S
Supply and fix in repair 36 watts LED flat panel 1x4 feet glare free opal difuser recess /surface mounted complete with 36 watts LED and inbuilt surge protection device all reqd at site complete all as specified and as directed
M&Lfor sub main wiring with two single core, PVC insulated,ISI marked, unsheathed, 1100 volts grade multistranded copper conductor cable drawn into and including suitable size non metalic rigid pvc concealed conduit (ISI marked) concealed/surface with all accessories and including one single core pvc insulated multistranded unsheathed 1100 volts grade copper conductor cable as earth wire of 2x4.0 sqmm + 1x4 sqmm earth wire size as in repair incl cutting and chasing and making good thw disturbed surface to match the existing complete all as directed & specified.
All as per item No 46 above but 2x6.0 sqmm + 1x6.0 sqmm earth wire
M&Lfor sub main wiring with four single core, PVC insulated,ISI marked, unsheathed, 1100 volts grade multistranded copper conductor cable drawn into and including suitable size non metalic rigid pvc concealed conduit (ISI marked) concealed/surface with all accessories and including one single core pvc insulated multistranded unsheathed 1100 volts grade copper conductor cable as earth wire of the 4x4sqmm + 2x2.5 sqmm earth wire size as in repair incl cutting and chasing and making good thw disturbed surface to match the existing complete all as directed & specified. Make of cable -Havells/Finolex/Nicco
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made 2 way SPN suitable for MCB DB's 240 Volts with neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 6 way SPN suitable for MCB DB's 240 Volts with 100 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 100 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 12 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way TPN suitable for MCB DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete as in repair all as specified and directed. Make Legrand/ABB/C&S/Havells/Indoasian
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way VTPN (IP43) suitable for and incl MCCB TPN 100 mps 16 KA, DB's 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting as in repair complete all as specified and directed. Make Legrand/ABB/Hager
S&F in repair MCB single pole ISI marked ISI Marked `B' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA as in repair etc all as specified and directed.
S&F MCB single pole ISI marked ISI Marked `B' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 40-63 Amp breaking capacity 10 KA as in repair etc all as specified and directed.
S&F MCB in repair single pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacityas in repair etc all as specified and directed. Make Legrand/Schnieder /Hager
S&Fin repair MCB triple pole and neutral ISI marked `B' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40-63 Amps 10 KA breaking capacity as in repair etc all as specified and directed.
S&F MCCB TPN 63 Amp fixed type 16 KA fixed thermal & fixed magnatic setting suitable for 415 volts as in repair. Make : legrand/C&S/ABB/Havells/Indoasian
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 60 here-in-before but 50 litre capacity.
Supply and fix in repairs Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 62 here-in-before but 50 ltr capacity.
Supply and fix in repairs Heating element 2 KW ISI Marked
Supply and fix in repairs Heating element 1.5 KW Make for item No 81&82 :- RECOLD / VENUS / GILCO / PREMIER / CHEETA /Bajaj/CROMPTON
Supply and fix in repairs Thermostat switch ISI Mark
Supply and fix in repairs Safety valve
Supply and fix in repairs Indicating Lamp Round /Square
Supply and fix in repairs 23 to 30 cm long ,10 mm bore C.P Connection with brass union
Supply and fix in repairs Gun metal non return valve ,15 mm bore
Supply and fix in repairs 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe
Supply and fix in repairs Apparatus plate for 25 litre / Syphon Assy
Supply and fix in repairs Apparatus plate for 50 litre / Syphon Assy
Supply and fix in repairs Plug top 3-pin, 16 Amp
Supply and fix in repairs Rubber O ring /gaskit for 25 ltrs
Supply and fix in repairs Electric water storage Heater (vertical type Geysers) 25 Ltrs BEE 5 STAR, 230 volts AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement .Geysers to have glass lines tank, fero glass coated container,PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc.including cutting holes and making good the disturbed surface complete all as specified and as directed Make : Havells/Venus/Bajaj
M&L for in repair earthing in repair complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 4 metre deep below ground level) vertically, with top edge of the plate not less than 3.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one sigle pole MCB `B' series 20 Amps 240 volts etc complete as specified and directed .
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 6 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 10 sqmm in service connections suspen- ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core 16 sqmm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 core 25 sqmm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 35 sqmm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 50sqmm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 95sqmm nominal cross section in service connections
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 120sqmm nominal cross section in service connections
M&L bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos and iron lead and suitable to accommodate 4 pole 63-100 Amps MCCB and provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface . Note : MCCB shall be measured and paid separately
Supply and fix in repair MCCB 4 pole 100 Amps 16 KA complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width incl cutting of road/path and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed.Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
Supplying, laying GI tubing, 40 mm bore, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.
Supplying, laying GI tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete 150 mm thich Type D-2, 1:4:8 (40 mm graded crushed stone aggregate as in repair of road/path cutting
Supply anf fix in repair AC ceiling fan 1200 mm sweep with remote control conforming to BEE 5 star rating complete with set of aluminium blades, down rod and set of canopy. Make :Superfan/ USHA/Crompton/Havell/Bajaj.
Supply and fix in repair AC Exhaust fan 100 mm sweep high air delivery low noise complete with diffusers Make : USHA/Crompton Havells. .
Supply and fix in repair wall mounting AC fan 400 mm sweep with remote control conforming to BEE star rating. Make : USHA/Crompton/Havells/Bajaj
Supply and fix in repairs mild steel body desert cooler (elect driven) single phase having air flow/delivery 3000 cum/hrs duly painted with synthetic enamel paint on external surface & black Japan paint on internal surfaces with gun spary machine. The desert cooler body shall be fabricated with the sections as under :- (a) Top & bottom of the body shall be of 1.25mm thick MS galvanised sheet. (b) Sides panel of the body (set of three) made out 1 mm thick MS galvanised sheet with wood & wire netting of GI wire 1.4mm dia 25mm mesh for holding pads. (c) Front grill of suitable size and approved quality mild steel. (d) Fixing of fan motor with blades, water lifting pump and electric wiring /fittings. Desert coolers shall be fitted with kits consisting of fan motor, submersible tullu pump & three step regulator of Make Khaitan/Bajaj /CG/Symphony
Supply & install in repair Air conditioner split type (indoor and outdoor) elect driven single phase of capacity 1.5 TR with copper tubing upto 10 mtr as required and providing seasoning tape /insulation tape, metal stand for outdoor unit a Floor/Wall etc and making good the disturbed surface complete with R-410 gas, 3 star rated. Make: Voltas/ career/Samsung/Hitachi
Supply, , fixing and testing in repairs split type Air condioner 3 star rating unit with indoor and out door having hot & cold provn operated unit single phase 220 volt complete of capacity 2 Ton. Installation includes copper tubing as required up to 10 mtrs and providing seasoning tape etc. and making good disturbed surfaces complete as directed by Engineer in charge.Make- voltas/career/samsung/Hitachi.
Supply and install in repair room window type air conditioner (with R410 gas) electric driven (single phase), cooling capacity 4500 K cal per hour, three star rated, capacity 1.5 ton, 230 volts complete including sealing of window with 6 mm thick ply. Make: Voltas/ career/Samsung/Hitachi.
.Supply and fix voltage stabiliser for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 Volt to 250 Volt with out put voltage stabilised at 230 Volt with accuracy of plus minus 2.5 % and of capacity 20 Amp/ 4.0 KVA Make- V guard/logistat/servokon/stallian.
Supply fixing incl testing in repairs of Refrigerator (double door) single phase electric driven of 310/320 ltrs BEE 5 star capacity complete all as specified and as directed by Engineer-in-Charge. Make: VOLTAS/SAMSUNG/LG
S &F in repairs energy saving LED street light 40 to 45 watt luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium housing with top openable driver compartment built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and incl sealed/compact driver for easy access during maintenance with the following specifications :- (a) Front cover - Clear toughned glass only.(b) Ingress protection - IP -66 (c) System efficacy - > 100 Lumen/watt.(d) LED efficay - > 100 Lumen/watt. (e) CRI - > 70.(f) CCT - 5700 K ±300 (g) Lense - Should have indl lense on each LED for better distribution (h) Wattage of LED - More than 3 watts and less then 6 watts (j) Driver - Isolated, Constant Current, Repairable type, suitable for 30Vdc & 1.30A. Driver and fixture should be of same make. Driver should have 5KV inbuilt surge protection (k) Mounting dia of fixture - not less than 40 mm (l) Power factor - >0.95.(m) I/P Voltage Range- 140 to 270 Volts (n) THD - <10%. (o) External Surge Protection -20 kv outside the fixture (p) High Voltage Cut off - 300V ± 10V.(q) Make of LED - Osram, Cree, Nichia, Seoul (r) Discharge surge current ( Imax)- 10kA (8/20 µs (s) Nominal discharge surge current ( In)-5kA (8/20 µs) Make of LED fixture : Wipro/Crompton/Halonix/Philips /Bajaj Make :- Philips / Bajaj / Osram/Halonix/C&S Note:(i) Brand logo Shall be Embossement on the fitting and paper sticker will not be acceptable . (ii) Batch No shall be written in the fitting (ii) Local representative of the company will certifiey the complaince of the specification of the luminaries and genunity
S &F in repaire energy saving LED street light 25 to 30 watt luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium body with built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and incl sealed/compact driver for easy access during maintenance,suitable for operating on voltage 120 - 270 volt,AC,50 HZ,with inbuilt surge protection device having maximum discharge surge current( Imax) -10kA (8/20 µs) ,Nominal discharge surge current ( In)-5kA (8/20 µs) and protection level (Up) upto 1 kv., out put Luminous efficacy not less then100 Lumen/Watt , CRI more then 70, conforming to IP 66, class 1 complete all as per Manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
S &Fin repairs energy saving LED flood light fittngs 150 watts luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium housing with top openable driver compartment built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and incl sealed/compact driver for easy access during maintenance with the following specifications :- (a) Front cover - Clear toughned glass only,(b) Ingress protection - IP -66 (c) System efficacy - > 100 Lumen/watt.(d) LED efficay - > 100 Lumen/watt. (e) CRI - > 70.(f) CCT - 5700 K ±300 (g) Lense - Should have indl lense on each LED for better distribution (h) Wattage of LED - More than 3 watts and less then 6 watts (j) Driver - Isolated, Constant Current, Repairable type, suitable for 42 Vdc & 2.7A. Driver and fixture should be of same make. Driver should have 5KV inbuilt surge protection (k) Power factor - >0.95.(l) I/P Voltage Range- 140 to 270 Volts m) THD - <10%.(n) External Surge Protection -20 kv outside the fixture (o) High Voltage Cut off - 300V ± 10V (p) Make of LED - Osram, Cree, Nichia, Seoul (q) Discharge surge current ( Imax)- 10kA (8/20 µs (r) ,Nominal discharge surge current ( In)-5kA (8/20 µs) Make of LED fixture : Wipro/Crompton/Halonix/Philips /Bajaj/Osram/
S& F in post top decorative globe type lantern LED 30 Watt (neutral white) with high efficient LED and polycarbonate diffuser, sutable MS/die cast alumn spigot mounting assebly ,glare free conforming to IP 65 ptrotection with and incl necessary fixing arrangement complete all as specified including taking down old unserviceable fittings of any size/ wattage complete and as directed by Engineer -In-Chrge
S& F in prismatic midbay 50 watt LED pendent luminair with fluted polycarbonate reflector and cover .integral aluminium spun housing with inbult driver ,glare free conforming to IP 65 ptrotection with and incl necessary fixing arrangement complete all as specified including taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
S&F in repairsLED Bollard 10Watt with die cast aluminium housing with polycarbonate housing and cylinder diffuser IP 65 conforming to cat part No HLOB -03-10-CW of Halonix or equivalent in Cromption/Bajaj/C&S complete with 10 watts LED, Driver and surge protector including making new connection with three core PVC copper flexible cable of size 23/.0076
Supply and install digital timer switch in sheet metal encloser havig the contact rating : 16A AC1 USB key version : EG103E. 1 channel weekly cycle 56 adjustment pre recording programme two moudules with impulse and holiday function having the contactors rating all for AC 7A lead only (Coil voltage 230V 50Hz). for remote switch control a power circuit 3 No, 63 A 3 modules complete with one no MCCB 4 pole 63 Amps - 01 Nos and power contactor 63 Amps all as per manufacturer's specificationsincluding taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
Supply only PVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) 3 core for repair of street light wherever required at site and as directed by Engr -in-charge.
Supply only LED surge protection device having maximum discharge surge current (Imax) -10kA (8/20 µs), Nominal discharge surge current ( In)-5kA (8/20 µs) and protection level (Up) upto 5 kv. up to 200 watt security light /flood light fitting Make : Crompton/Halonix/Philips /Bajaj
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 30 Vdc & 1.3A. Driver . Make Crompton/Halonix/Philips /Bajaj
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 42 Vdc & 1.27A. Driver . Make Crompton/Halonix/Philips /Bajaj/
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 42 Vdc & 1.42A. Make Crompton/Halonix/Philips /Bajaj
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 54 Vdc & 1.50A. Make Crompton/Halonix/Philips /Bajaj
Supply only LED street light fitting driver Isolated, Constant Current, Repairable type, suitable for 48 Vdc & 2.7A. Make Crompton/Halonix/Philips /Bajaj
S&F street light bracket made out of 40mm dia, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30 x 5mm, with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer including taking out existing unserviceable rusted GI bracket complete all as specified and as directed.
unique power & control system
LONGIA ENGINEERS
Arun enterprises
Electromech Engineers
M/S RAGBIR ENGINEERING SERVICES
M/S MATLOOB AHMED
M/s Super Trading Corporation
GLIBS CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .