Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
2 Dec 2022, 6:00 pmClosed
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
REPAIR/ MAINT TO EXTERNAL ELECTRIC SUPPLY, STREET/ SECURITY, GARDEN AND SOLAR LIGHTS AT POCKETS A, B, D, E AND 42 WEU UNDER GE AF TRIVANDRUM
2022_MES_556127_2
8399
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Trivandrum
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹44,000
Yes
12 Dec 2022
10 Nov 2022
5 Dec 2022
10 Nov 2022
2 Dec 2022
18 Nov 2022
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable and getting out in soft/loose soil complete all as specified and directed
Removing excavated material not exc 50m and depositing where as directed at a level not exc 1.5m above the starting point complete all as specified and directed
Returning, filling of excavated soil upto a depth of 30cm after riddling the excavated soil for cushioning of cable and refilling of trench with normal excavated soil all as directed.
Supply and lay in trenches burnt bricks sub-class ‘B’ size for cable protection complete all as specified and directed.
M&L for PCC 1:3:6 Type C1 with 20 mm graded aggregate for coping, over road cutting surface complete including necessary form work complete all as specified and directed.
M&L for in replacement GI pipe 50 mm dia light grade laid in trenches at road crossings/ foot paths complete all as specified and directed
All as per item No 7.00 above but pipe dia 80 mm.
All as per item No 7.00 above but pipe dia 40 mm.
Taking out old defective under ground cable from trenches/ floor / road / wall / pipe/ pole of any size and description, complete all as directed.
Labour for re-laying the serviceable part of cables of any size taken out vide item No 10.00 above, after repairing defects / making joints etc in same trench or any other location, complete all as directed by Engr-in-charge. Note : 1. The excavation, earth work, sand cushioning, protection cover, and cable joints etc will be measured and paid for separately under respective items of this schedule.
Supply and laying in trenches or passing through pipes/ poles, wall/roof etc LT XLPE cable heavy duty 1100 Volts grade with multistranded aluminium conductor, armoured of the following sizes including provn of cable lugs and glands as required complete all as specified and directed
4 core 6 sq mm
4 core 10 sq mm
4 core 16 sq mm
4 core 25 sq mm
3.5 core 50 sq mm
3.5 core 95 sq mm
3.5 core 150 sq mm
Supply only Heat shrinkable LT 1.1 KV straight through joint suitable for aluminium cable of Size 185 Sqmm to 300 sqmm x 3.5 core .
All as per item No 13 above but for cable size 70 Sqmm to 150 sqmm x 3.5 core .
All as per item No 13 above but for cable size 25 Sqmm to 50 sqmm x 3.5 core .
All as per item No 13 above but for cable size 10 Sqmm to 16 sqmm x 3.5 core .
Supply and fixing in replacement HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 270 mm x 225 mmx 135 mm ( inside dimension) incl 4 way heavy duty terminal block with 01x MCB 10 Amps SP, 10 KA and two number of PVC cable entry gland of standard size with suitable GI bracket to fix with pole, including taking down existing complete all as directed. Make: Sintex Part No GSJB-2136 or equivalant in Hansel
M& L for 3 core 1.0 Sqmm multistranded copper conductor PVC insulated unsheathed cable to connect from junction box to street light fitting drawn through and including rigid non metallic PVC conduit medium grade fixed on pole by means of clamps made out of MS flat irons and connecting from terminal box to light fitting and testing including taking down existing perished wiring complete all as directed complete all as specified and directed.
Cutting and brooming and clearing tree branches/ plants/ bushes obstructing the LT poles up to girth of 30cm on both sides including disposal of materials to a distance of 50 meters complete all as specified and directed by Engineer - in - Charge Note: The quoted rate is inclusive of T & P as required for the work.
M& L for cleaning away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and trees and rubish upto a distance a 50 mtr out side / inside the periphery of the area under clearance of HT yard/ sub station area complete all as specified.
Checking of street light / flood light/ solar light of any type or description, fixed in vertical position with poles / high mast / wall/ bldg security light, including disconnecting the electric connection and taking down from pole / high mast / wall. Cleaning of acrylic/glass sheet cover with detergent powder, and refixing the same after necessary repairs including replacing defective items provided under relevant items of Sch 'A' here-in-after as supply & fixing only, replacing of fuses, small wires of any size and description upto 1.0 mtrs, screw, washer for fixing of accessories, making all electric connection, testing for functioning, by engaging sufficient man power and tool & plant etc to ensure safety of light / pole as well as working team complete all as directed.
Note : (a) Any kind of replacement of major items shall be measured & paid separately under respective items of schedule. (b) The cost of Tool & plant for street light repairing vehicle is deemed to be included in quoted rates and no extra payment will be paid to the contractor in this effect. (c) Contractor shall arrange a staff to monitor the street light repairing team and maintain the complaint register and complaint slip. (d) Complaint once lodged should be rectified within 24 hrs and after rectification slip should be signed by JE E/M.
Notes contd : e) If the nature of job is such that the work cannot be completed within period of 24hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for rectifying the complaint shall be decided by the GE/EIC. If the delay is more then 24 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforced above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. (l) The decision of the Accepting Officer in this regard shall be final and binding.
S & F in replacement 45 W street light driver suitable for existing LED fittings. Make : Philips/ CG/Havells/ Wipro
S & F in replacement 70W street light driver suitable for existing LED fittings. Make : Philips/ CG/Havells/ Wipro
S & F in replacement 30 W flood light driver suitable for existing LED fittings. Make : Philips/ CG/Havells/ Wipro
S & F in replacement 70 W flood light driver suitable for existing LED fittings Make : Philips/ CG/Havells/ Wipro
S & F in replacement 150W Flood light driver suitable for existing LED fittings. Make : Philips/ CG/Havells/ Wipro
S & F in replacement Post top 45W driver suitable for existing LED fittings. Make : Philips/ CG/Havells/ Wipro
Supply and fixing in replacement of 30 W street light with a nominal efficiency >115 lumen/watt, finless design made of non-corrosive high-pressure die-cast aluminum housing, having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related color temperature (CCT) of 5700K, Ingress protection (IP) 66 with an IK rating of 08. Luminaire and driver shall be separately BIS approved of same make or equivalent. Make : Philips BRP042 LED 30 CW SLF PSU S1 / Wipro LR02-501-XXX-57-XX / bajaj BRTFG 45W
Supply and fixing in replacement of 35W flood light with a nominal efficiency 135 lumen/watt of non-corrosive ADC12 Grade high-pressure die-cast aluminum housing, corrosion resistant coating, minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related color temperature (CCT) of 5700K, The Ingress protection should be minimum IP 66 with an IK rating of 07, 10 KV SPD should be able to sustain a minimum 15 hits of 10KV rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. Note: The Drivers should be a potted driver mounted inside the luminaire, Luminaire and driver shall be separately BIS approved of same make. Make: Philips- BVP120 LED 47 CW NB FG A1 PSU GR /Wipro/ Bajaj
Supply and fixing in replacement of 60 W street light with a nominal efficiency >130 lumen/watt, having finless design made of non-corrosive high-pressure die-cast aluminum housing, having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related color temperature (CCT) of 5700, IP 66 with an IK rating of 08, Luminaire and driver shall be separately BIS approved of same make. Make: Philips BRP062 LED 65 CW SLA S1 PSU /Havells TYCOONPT70W / bajaj BCF FLO 60W.
Note for item Ser No 22 to 30 (i) Quoted rate is deemed to include rate of cable connection upto 0.5 mtr long of size 3 core x 0.75 sqmm. (ii) Contractor shall be responsible for proper fixing of fitting with existing location ie. Poles/ walls. (iii) Contractor shall be bound to give warranty of minimum 3 yrs from date of installation for fittings.
Taking shut down LT Supply from Servo voltage stabilizer air cooled of capacity 12 KVA to 50 KVA and disconnecting cable from input/ out put terminal after opening the door for cleaning and servicing/ cleaning through the cleaning materials, checking of all check points/ terminal points, tuning of circuit, minor repairs of control card for smooth operating/ functioning of the equipments as per manufacturer instructions, including cleaning replacment of old u/s parts with new branded parts, complete all as specified.
Note : (a) Voltmeter , Ammeter, control card, tfr oil, toggle switch, CT's and other minor parts as required shall be measured and paid separatly under relevant items of this schedule as supply only. (b) After completion of the job, Servo voltage stabilizer shall be tested on load and test report shall be submitted duly signed by both the parties.
Supply only 28 amps motorised variac
Supply only 20 amps motorised variac
Supply only 15 amps motorised variac
Supply only servo motor 3 kg
Supply only servo motor 10 kg
Supply only RC for servo motor
Supply only Digital servo control card with connector.
Supply only Auto/ manual toggle switch
Supply only push to ON
Supply only indicator 22 mm L&T
Supply only low/ high indicator
M&L for preparation of old painted surfaces by cleaning / scraping with wire brush, removing fungus/algae and dust of pre stressed concrete poles of size 7.5 Mtr above ground level and applying two coats of synthetic enamel paint to the pole including coping and applying two coat of aluminium paint over a coat of red oxide primer on street light brackets/ clamps, etc and writing pole number in Black & white paint (Number shall be 50 mm) complete all as specified and directed by Engineer-in-charge. (Note : The quoted rate inclusive of two coats of Painting Blue and white strips in alternate layers with synthetic enamel paint up to 1 mtr height above coping of pole as directed.)
M&L for cleaning, scrubbing and preparation of old, rusted painted surface of existing steel tubular pole of 09 to 11 mtr height complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making black & white alternative strips of 30 cm height with synthetic enamelled paint and upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint complete all as directed.
Disconnecting the old battery from the solar light pole after opening the sheet metal box and M& L, installation in-replacement of Lead acid battery 120 AH 12 Volts suitable for existing solar street light in various location all as specified. Note: Contractor shall summit the warranty of battery minimum 24 month after installation.
M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boulders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed.
Taking out battery from rusted battery box mounted on solar street light pole, dismantling the old rusted box and M&L for refixing of new battery box with minimum thickness of sheet 3.15 mm for the battery 12 volts 120 AH or as per existing size complete including two coat of synthetic enamel paint over a coat of synthetic primer all as specified.
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as directed.
M&L for road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/ stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed.
S&F in replacement street light panel 3 phase frame of capacity 40 A 3 Pole incl Digital timer, power contact, isolator 4 pole, indicator lamps with switch for bypass arrangement and fixing by making proper foundation with angle iron frame or fixed in pole all as directed by Engr -in-charge. Make : Indoasian Part No TL040DB0/ L&T/ Havells.
Supply and fixing in replacement of MCCB, 415 volts, four pole of capacity 100 Amps, 25 KA, adjustable thermal- magnetic release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections and taking down old unserviceable MCCB, complete all as directed. Make: Legrand/ L&T.
All as per items No. 52 here-in-before but 125 Amp capacity, 25 KA
All as per items No. 52 here-in-before but 160 Amp, 25 KA capacity
All as per items No. 52 here-in-before but 200 Amp, 25 KA capacity
All as per items No. 52 here-in-before but 63 Amp, 25 KA capacity
Supply& fixing in replacement of MCB 4 pole C curve 40 amps 10 KA capacity all as specified and directed.
Supply& fixing in replacement of MCB 4 pole C curve 63 amps 10 KA capacity all as specified and directed.
Supply& fixing in replacement of MCB SP C curve 10 amps 10 KA capacity all as specified and directed.
Supply & Fixing in repairs of metal clad plug of capacity 32 amps 3P+E, 230/415 Volts . Make : Indoasian Cat No 810388 or equivalent in Havells.
Supply & Fixing in repairs of metal clad socket of capacity 32 amps 3P+E, 230/415 Volts . Make : Indoasian Cat No 810392 or equivalent in Havells.
CHITHRANI TRADERS
VISHNU
CHAUHAN ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .