Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.0 L+₹54,880 (2.98%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹23.3 L+₹4.9 L (26.4%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹23.7 L+₹5.3 L (28.5%)Rejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹25.6 L+₹7.2 L (38.9%)Rejected-AOC 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L5 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE (AF) No 02 Jodhpur
GE(AF) No. 2 Jodhpur AF Stn Jodhpur
Maintenance of internal electrification, light fittings and allied work at Offrs Mess, NCOs Mess Airmen Mess No 1 and Airmen Mess nO 3 at AF Stn Jodhpur and repair and maint of electric geysers at OMQ SMQ and OTM accns at outer and inner pockets of d
2024_MES_669803_1
8476/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 02 Jodhpur
₹70,000
Yes
25 Oct 2024
2 Sept 2024
30 Sept 2024
2 Sept 2024
28 Sept 2024
16 Sept 2024
2 Sept 2024 - 9 Sept 2024
Amount
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, concealed wiring , GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : -
One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
One light point controlled by two Nos 5 Amps switch two way
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independant board.
One bell point controlled by one switch 5 Amps bell push.
All same as per item ser No 2.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
All same as per item ser No 2.00 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, FRLSH,single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers.
S&F Switch piano, flush type, single pole, one way,5/6 Amp.
S&F Switch piano, flush type, single pole, one way, 16 Amp.
S&F Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
S&F Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
S&F(in repairs) Ceiling rose surface bakelite 65x50mm three terminal.
S&F (in repairs) Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
S&F Stepped type electronic fan regulator, switch size, flush type 230V AC.
S&F electronic Bell Bul-Bul music, 230 volt, single phase.
S&F bell push, type, 6 Amps, 2 Module
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F electronic fan regulator modular stepped type 120 watt, two module.
S&F modular white or Ivory cover plate with frame 1 module
S&F modular white or Ivory cover plate with frame 2 module
S&F modular white or Ivory cover plate with frame 3 module
S&F modular white or Ivory cover plate with frame 4 module
S&F modular white or Ivory cover plate with frame 6 module
S&F modular white or Ivory cover plate with frame 8 module
Taking out existing unserviceable switch board plates any type, dismantling switches cafully, stacking at site for use of serviceable switches and supply and fixing new 3mm thick masonite laminated sheet top cover fixed on 6/8 inch x 10 inch MS box and brass screw for mounting switches, sockets, regulator etc including making necessary electrical connection with 1.5 sqmm single core copper mulitstranded cable all as directed at site by Engineer-in-charge. Note : New Switches, sockets, fan regulators etc if required will be measured and paid separately under relevant items.
All as per item ser No.25.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 6/8 inch 4 inch MS box.
All as per item ser No. 25.00 here-in-before but new 3mm thick masonite laminated sheet top cover white or ivory fixed on 4 inch x 4 inch MS box.
Supply and fixing in repair of LED lights fitting 1x 20W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antena on roof of building complete all as specified. Note : 20mm conduit pipe inside building shall be concealed in wall surface and from external surface duly fixed with GI Saddles is deems to be included in quoted rates.
M&L for MCB TPN/FP, 63 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make -L&T ,Legrand,havells
M&L for MCB TPN/FP, 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Make -L&T ,Legrand,havells
M&L for SPN/DP RCBO 63 Amps 240 volts, 30 mA capacity and 10 kA rupturing caoacity providing in DB complete including connection & testing all as specified. Make- Havells cat part no-DHCEACSN2030040Make -L&T ,Legrand,havells
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.Make -L&T ,Legrand,havells
Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color. (for SMQ)
Labour only for attending complaints of unserviceable electric geysers and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner pockets) carrying out necessary repairs at site by taking down carefully unserviceable geysers by disconnecting electrical connections, unsecrewing from position, carry out necessary minor repairs at site and re-install the geyser after repair at site or removing geysers to workshop for major repairs (like repairs to inner tank or body) or deposit unrepairable geysers to E/M Store yard safe coustody all as directed and specified. Note : Necessary spare parts required to repair at site shall be measured and paid separately under relavant items. Necessary deposit receipt shall be provided to users for taken down Geysers as per prescribed format given MES. Contractor shall arrange necessary transportaion to bring the taken down geysers for repair/replacement.
Supply and fix in repairs Heating element copper body chromium plated of rating 1.5 KW, 230 volts ISI marked, 10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Supply and fix in repairs Heating element copper body chromium plated of rating 2.0 KW, 230 volts ISI marked, 8/10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Supply and fix in repairs Heating element for new model enegry efficient geysers, copper body chromium plated of rating 2.0 KW, 230 volts ISI marked, 10 inch long, and dia of tube not less than 8.5mm, cup type base including rubber ring washer suitable complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
M&L for point wiring with 2.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed .
M&L for point wiring with 4 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 4 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed .
S&F(in repairs) Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
Supply and fix in repairs 3 Pin Plug Top 16 Amps, 240 volt insulated bakelite body(Ivory/White)
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN 40-63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and fix in repairs metal clad, 2 Pin+Earth Plug SOCKET only 16 Amps, 240 volt.
Supply and fix in repairs metal clad, 2 Pin+Earth Plug Top 16 Amps, 240 volt.
Supply and fix in repairs Thermostat (8/10 inch long) auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs Thermostat (8/10 inch long) auto cut with trip reset push button type, 230 V, for the geysers 25/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs capillary type Thermostat suitable for new gernation energy efficient geyser for tempterature control auto cut function, 230 V, size and capacity as per site requirement complete all as specified and as directed by Engr-in-Charge .
M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 450mm long as per Cat No GSSGGX0030 of Make Havells or equivalent in approved makes.
Supply and fix in repairs Heat resistant heavy duty pressure grade 6 kg/sq cm, stainless steel wiremesh braided HOT & COLD flexible PVC connecting pipe with brass adapters 600 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge. Make-Havells/Crompton or as per approved makes.
M&L for replacement of HOT & COLD PVC water connection pipes stainless steel braided flexible pipe 750mm long of Make Havells or equivalent in approved makes.
Supply and fix in repairs Non return valve 15mm bore,as per site requirement complete all as specified and as directed by Engr-in-Charge
Supply and fix in repairs LED Indicator lamp red/green complete all as diercted by Engr in Charge
Supply and fix in repairs Apparatus base plate (Geysers assembly) suitable for existing Geysers of Cap 25 Litres of copper /brass complete with nuts and bolts and rubber washers complete all as specified and directed by Engr in Charge.
Supply and fix in repairs Apparatus base plate (Geysers assembly) suitable for existing Geysers of Cap 50 Litres of copper /brass complete with nuts and bolts and rubber washers complete all as specified and directed by Engr in Charge.
M&L for cutting holes 300mm diameter for preaparing opening through brick/stone masonary wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall all as directed by Engr-in-charge at site
Supply and fix in repairs, syphon assembly with rubber gasket, including nuts, bolts, washers etc following capacity of geysers, complete all as specified and as directed:-
50 Litres capacity geysers.
25 Litres capacity geysers.
Supply and fix in repairs inner tank, vessel made of copper sheet 22 gauge , ISI marked factory made for suitable pressure of following capacity, complete all as specified and as directed:-
50 Litres capacity .
25 Litres capacity.
Note (a) The contractor will deploy sufficient resources for completion of day to day comaplaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit suitable penalties as mentioned in relavant clause of Contract. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him. (c) The contractor will make suitable arrangment for emergent complaints and will notify JE/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rated deems to be inclusive of transportation, T&P and other expenses required for the resource deployment at the complaint site around scattered at AF Station Jodhpur. (f) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically by Engr-in-charge or JE detailed by him to streamline complaints disposal system.
Shiv Shakti Enterprises (BID ID -3104008)
M/S KAUTILYA GARG (BID ID -3104789)
KRISHNA CONSTRUCTION COMPANY (BID ID -3103443)
M/s Shiv Builder and Suppliers (BID ID -3104667)
Nvimal Engineers and Contractor (BID ID -3099965)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .