Department of Medical Education
estate officer
WORK REGARDING THE INSTALLATION OF AN ADDITIONAL 750 KVA TRANSFORMER AND A 750KVA DG SET TO SUPPLY POWER TO THE INCREASING NUMBER OF MEDICAL DEVICES AT THE KARNATAKA MEDICAL COLLEGE AND RESEARCH INSTITUTE CAMPUS
DME/2026-27/SE0798
DME/2026-27/SE0798
Open
Two Tender Document System(Two Cover)
Karanataka Institute of Medical Sciences Hubli
Whether tender form fee is remitted
Whether Demand Draft towards E.M.D is enclosed
Certificate of P.W.D Civil & Electrical Class-III Contractor Registration
TURNOVER CERTIFICATE : Achieved in at least two financial years a average financial turnover of Rs.84.73 lakhs
SINGLE WORK DONE CERTIFICATE : Satisfactorilly completed work of value Rs.42.37 lakhs as prime contractor, at least one similar work such Electrical work.
QUANTITIES WORK DONE CERTIFICATE Minimum quatities of work executed in any one year during last 5 years
a.500 KVA Copper Winding, Distribution Transformer - 1 Eachb. 500 KVA Diesel Genrator Set With AMF Panel - As Per CPCB Norms -1 Setc. 3Way RMU, 2 OD + 1 VL 1 Each
Latest Income Tax Clearance certificates & GST Certificate with GSTR 3B with last 3 months Paid Challans
Certificate of PAN Card registration
Certificate of Latest EPF registration with last 3 months Paid Challans
Certificate of ESI registration with last 3 months Paid Challans
Certificate of Labour registration
Whether original liquid assets/ availability of credit facility of not less than Rs.26.00 lakhs
Certificate oProof of site visit certified by Estate Officer If the site inspection letter is not taken from the Estate Officer, such a contractor will be considered ineligiblef PAN Card registration
₹500
₹2 L
5 Sept 2026
5 Sept 2026
17 Sept 2026
8 Sept 2026
LIST OF DOCUMENTS TO BE ENCLOSED BY CONTRACTOR FOR QUALIFICATION OF TENDER
Name of work :- ಕರ್ನಾಟಕ ವೈದ್ಯಕೀಯ ಮಹಾವಿದ್ಯಾಲಯ ಮತ್ತು ಸಂಶೋಧನಾ ಸಂಸ್ಥೆ ಆವರಣದಲ್ಲಿ ಹೆಚ್ಚುತ್ತಿರುವ ಮೆಡಿಕಲ್ ಉಪಕರಣಗಳಿಗೆ ವಿದ್ಯುತ್ ಪೂರೈಸಲು ಹೆಚ್ಚುವರಿಯಾಗಿ 750ಕೆವಿಎ ಟ್ರಾನ್ಸಫರ್ಮರ್ ಮತ್ತು 750ಕೆವಿಎ ಡಿಜಿ ಸೆಟ್ ಅಳವಡಿಸುವ ಕಾಮಗಾರಿ.
Sl. No. DOCUMENTS TO BE ENCLOSED Certificate issued by
1 Whether tender form fee is remitted
2 Whether Demand Draft towards E.M.D is enclosed
3 Certificate of P.W.D Civil & Electrical Class-III Contractor Registration Competent authority
4 TURNOVER CERTIFICATE : Achieved in at least two financial years a average financial turnover of Rs.84.73 lakhs Chartered accountant
5 SINGLE WORK DONE CERTIFICATE : Satisfactorilly completed work of value Rs.42.37 lakhs as prime contractor, at least one similar work such Electrical work. Competent authority
6 QUANTITIES WORK DONE CERTIFICATE : Minimum quatities of work executed in any one year during last 5 years. Competent authority
a.500 KVA Copper Winding, Distribution Transformer - 1 Each
b. 500 KVA Diesel Genrator Set With AMF Panel - As Per CPCB Norms -1 Set
c. 3Way RMU, 2 OD + 1 VL – 1 Each
7 Latest Income Tax Clearance certificates & GST Certificate with GSTR 3B with last 3 months Paid Challans Competent authority
8 Proof of site visit certified by Estate Officer (If the site inspection letter is not taken from the Estate Officer, such a contractor will be considered ineligible) Estate Officer KMCRI Hubballi
9 Certificate of PAN Card registration Competent authority
10 Certificate of Latest EPF registration with last 3 months Paid Challans Competent authority
11 Certificate of ESI registration with last 3 months Paid Challans Competent authority
12 Certificate of Labour registration Competent authority
13 Whether original liquid assets/ availability of credit facility of not less than Rs.26.00 lakhs Line of credit from Nationalized Bank
Note : Conditional tenders are liable for rejection.
Estate Officer Direcotr
KMCRI, Hubballi KMCRI, Hubballi
ಕರ್ನಾಟಕ ವೈದ್ಯಕೀಯ ಮಹಾವಿದ್ಯಾಲಯ ಮತ್ತು ಸಂಶೋಧನಾ ಸಂಸ್ಥೆ ಆವರಣದಲ್ಲಿ ಹೆಚ್ಚುತ್ತಿರುವ ಮೆಡಿಕಲ್ ಉಪಕರಣಗಳಿಗೆ ವಿದ್ಯುತ್ ಪೂರೈಸಲು ಹೆಚ್ಚುವರಿಯಾಗಿ 750 ಕೆವಿಎ ಟ್ರಾನ್ಸಫರ್ಮರ್ ಮತ್ತು 750 ಕೆವಿಎ ಡಿಜಿ ಸೆಟ್ ಅಳವಡಿಸುವ ಕಾಮಗಾರಿ
RECAPITULATION SHEET
Sl. No. Description Estimated Cost in Rs.
1 Electrical Works
2 ADD 18% GSTIN
3 MISCELLANEOUS ROUND OFF 1860.69 10000000
Total Project Cost
(In Words : Rupees One Core Only)
ASSISTANT ENGINEER ESTATE OFFICER DIRECTOR
KMCRI HUBBALLI KMCRI HUBBALLI KMCRI HUBBALLI
ಕರ್ನಾಟಕ ವೈದ್ಯಕೀಯ ಮಹಾವಿದ್ಯಾಲಯ ಮತ್ತು ಸಂಶೋಧನಾ ಸಂಸ್ಥೆ ಆವರಣದಲ್ಲಿ ಹೆಚ್ಚುತ್ತಿರುವ ಮೆಡಿಕಲ್ ಉಪಕರಣಗಳಿಗೆ ವಿದ್ಯುತ್ ಪೂರೈಸಲು ಹೆಚ್ಚುವರಿಯಾಗಿ 750 ಕೆವಿಎ ಟ್ರಾನ್ಸಫರ್ಮರ್ ಮತ್ತು 750 ಕೆವಿಎ ಡಿಜಿ ಸೆಟ್ ಅಳವಡಿಸುವ ಕಾಮಗಾರಿ
Sl. No. Description Unit Qty Rate Amount
1 Electrical SR - Vol 6 (2025-26) - SR. No: 39.03 - E Pg. 64 - Compact RMU (VCB/SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC 62271/IS-3427 5 Way RMU, 2 OD + 3 VL (One Incomer + Three Breakers + One Outgoing) Unit
2 Electrical SR - Vol 6 (2025-26) - SR. No:23.01 - E Pg. 108 - Transporting of RMU Transporting RMU (Coventional) unit from store to work spot including loading, unloading. (No separate crane charges) 5 Panel No
3 Electrical SR - Vol 6 (2025-26) - SR. No:23.07 - E Pg. 109 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., 1 Panel Per Panel
4 Market Rates - Distribution Transformer - 3 Phase, 11kV/433V - 500 KVA Copper Winding, both side bushings (Any Make approved by HESCOM) 500 KVA Distribution Transformer Each
5 Electrical SR - Vol 6 (2025-26) - SR. No:36.01 - E Pg. 62 - 11kV, 3 Core HTUG XLPE Insulated Cables as per IS-7098 (Part-2) 2011 with following parameters & as per BESCOM Requirements 95 Sqmm, (54 GI Wires - 2.5 mm Dia) KM
6 Electrical SR - Vol 6 (2025-26) - SR. No: 21.01 - E Pg. 107 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x95 to 150 Sqmm KM
7 Electrical SR - Vol 6 (2025-26) - SR. No:45.01 - E Pg. 70 - 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm Set
8 Electrical SR - Vol 6 (2025-26) - SR. No: 32.19 - E Pg. 58 - 1.1kV LTUG XLPE Insulated Cables as per IS-7098 (Part-1) with following parameters & as per BESCOM Requirements 300 Sqmm, 3.5 Core KM
9 Electrical SR - Vol 6 (2025-26) - SR. No: 21.08 - E Pg. 107 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 300 to 400 Sqmm KM
10 Electrical SR - Vol 6 (2025-26) - SR. No: 22.12 - E Pg. 108 - Heat shrinkable Straight Through Joint 300 to 400 Sqmm Set
11 Electrical SR - Vol 6 (2023-24) - SR. No:1.9.3- E Pg. 420 - Supplying PVC flexible conduit pipe ....mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or raw plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 32 mm MTR
12 Electrical SR - Vol 6 (2023-24) - SR. No: 1.3.3- E Pg. 419 - Supplying heavy gauge PVC Conduit Pipe .... dia .......mm thick with suitable size bends,metal junction boxes adhesive paste etc.,by groove cutting in the wall and ixing by bracing U or J hooks and cement plaster in gup to the wall surface and run with18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thick MTR
13 Market Rates - Diesel Genrator Set With AMF Panel - 3 Phase, 433V,50HZ - 500 KVA As Per CPCB Norms 500 KVA Diesel Genrator Set Set
14 Electrical SR - Vol 6 (2023-24) - SR. No: 1.6.2 - E Pg. 379 - Digging of Pit for providing GI Pipe type Earthing Hard Soil Per pit
15 Electrical SR - Vol 6 (2023-24) - SR. No: 12.58.10 - E Pg. 471 - Supplying fixing and wiring earth electrode for grounding of lifts,transformers,DG sets etc.using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and char coal from the bottom of the CC chamber.Theconnectionfromthe electrode is to be established through GI strip using GI bolts and nuts. 50 x 6 mm Copper strip Mtr
16 Electrical SR - Vol 6 (2023-24) - SR. No: 12.60.3 - E Pg. 472 - Supplying & Fixing Chemical earthling for grounding.Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits,superiorFault conductioncapacity, non toxic,weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound Kit
17 Vol 1 (2023-24) - SR. No: 1.14.1 - Pg. 8 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum
18 Vol 1 (2023-24) - SR. No: 1.10 - Pg. 7 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum
19 Vol 2 (2023-24) - SR. No: 6.2 - Pg. 13 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum
20 Vol 2 (2023-24) - SR. No: 8.1.2 - Pg. 41 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm
21 Vol 5 (2023-24) - SR. No: 9.1.2 - Pg. 95 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 75mm dia MTR
22 Electrical SR - Vol 6 (2023-24) - SR. No: 1 - E Pg. 236 - Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure. m³
23 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.19 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 500-630 A 50 kA Each
24 Electrical SR - Vol 6 (2023-24) - SR. No: 5.40.4- E Pg. 437 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips MTR
25 Electrical SR - Vol 6 (2023-24) - SR. No: 5.41.2 - E Pg. 437 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm MTR
26 Electrical SR - Vol 6 (2023-24) - SR. No: 5.42.1- E Pg. 437 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG cm2
27 SR - Vol 2 (2023-24) - SR. No: 11.58 - Pg. 95 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in-charge. (Made of G.I. wire of dia 4 mm) m2
28 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.16 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 36 kA Each
29 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.13 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 25 kA Each
30 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.9 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA Each
31 Electrical SR - Vol 6 (2023-24) - SR. No: 5.40.2 - E Pg. 437 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips MTR
32 Civil SR - Vol 1 (2023-24) - SR. No: 1.3 P.No.5 - Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm asperdrawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Cum
33 Civil SR - Vol 1 (2023-24) - SR. No: 1.11 P.No.7. - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. CUM
34 Civil SR - Vol 3 (2023-24) - SR. No: 4.1.401.A.II P.No.23. - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 CUM
ASSISTANT ENGINEER ESTATE OFFICER
KMCRI HUBBALLI KMCRI HUBBALLI
ಕರ್ನಾಟಕ ವೈದ್ಯಕೀಯ ಮಹಾವಿದ್ಯಾಲಯ ಮತ್ತು ಸಂಶೋಧನಾ ಸಂಸ್ಥೆ ಆವರಣದಲ್ಲಿ ಹೆಚ್ಚುತ್ತಿರುವ ಮೆಡಿಕಲ್ ಉಪಕರಣಗಳಿಗೆ ವಿದ್ಯುತ್ ಪೂರೈಸಲು ಹೆಚ್ಚುವರಿಯಾಗಿ 750 ಕೆವಿಎ ಟ್ರಾನ್ಸಫರ್ಮರ್ ಮತ್ತು 750 ಕೆವಿಎ ಡಿಜಿ ಸೆಟ್ ಅಳವಡಿಸುವ ಕಾಮಗಾರಿ
MEASUREMENT SHEET
Item. No. Description of work No Measurements Qty Total
1 Electrical SR - Vol 6 (2025-26) - SR. No: 39.03 - E Pg. 64 - Compact RMU (VCB/SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC 62271/IS-3427 5 Way RMU, 2 OD + 3 VL (One Incomer + Three Breakers + One Outgoing)
For Additional Load
5 Way RMU, 2 OD + 3 VL (One Incomer + Three Breakers + One Outgoing) 1
2 Electrical SR - Vol 6 (2025-26) - SR. No:23.01 - E Pg. 108 - Transporting of RMU Transporting RMU (Coventional) unit from store to work spot including loading, unloading. (No separate crane charges) 5 Panel
For Additional Load
5 Way RMU, 2 OD + 3 VL (One Incomer + Three Breakers + One Outgoing) 1 Civil item For Installation
3 Electrical SR - Vol 6 (2025-26) - SR. No:23.07 - E Pg. 109 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., 1 Panel
For Additional Load
5 Way RMU, 2 OD + 3 VL (One Incomer + Three Breakers + One Outgoing) 1
4 Market Rates - Distribution Transformer - 3 Phase, 11kV/433V - 500 KVA Copper Winding, both side bushings (Any Make approved by HESCOM) 500 KVA Distribution Transformer
For Additional Load
500 KVA Distribution Transformer 1
5 Electrical SR - Vol 6 (2025-26) - SR. No:36.01 - E Pg. 62 - 11kV, 3 Core HTUG XLPE Insulated Cables as per IS-7098 (Part-2) 2011 with following parameters & as per BESCOM Requirements 95 Sqmm, (54 GI Wires - 2.5 mm Dia)
For Additional Load
95 Sqmm, (54 GI Wires - 2.5 mm Dia) 0.025
6 Electrical SR - Vol 6 (2025-26) - SR. No: 21.01 - E Pg. 107 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x95 to 150 Sqmm
For Additional Load
7 Electrical SR - Vol 6 (2025-26) - SR. No:45.01 - E Pg. 70 - 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm
For Additional Load
8 Electrical SR - Vol 6 (2025-26) - SR. No: 32.19 - E Pg. 58 - 1.1kV LTUG XLPE Insulated Cables as per IS-7098 (Part-1) with following parameters & as per BESCOM Requirements 300 Sqmm, 3.5 Core
For Additional Load
300 Sqmm, 3.5 Core 1 0.105
9 Electrical SR - Vol 6 (2025-26) - SR. No: 21.08 - E Pg. 107 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 300 to 400 Sqmm
For Additional Load
10 Electrical SR - Vol 6 (2025-26) - SR. No: 22.12 - E Pg. 108 - Heat shrinkable Straight Through Joint 300 to 400 Sqmm
For Additional Load
300 to 400 Sqmm 4
11 Electrical SR - Vol 6 (2023-24) - SR. No:1.9.3- E Pg. 420 - Supplying PVC flexible conduit pipe ....mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or raw plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 32 mm
For Additional Load
12 Electrical SR - Vol 6 (2023-24) - SR. No: 1.3.3- E Pg. 419 - Supplying heavy gauge PVC Conduit Pipe .... dia .......mm thick with suitable size bends,metal junction boxes adhesive paste etc.,by groove cutting in the wall and ixing by bracing U or J hooks and cement plaster in gup to the wall surface and run with18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thick
For Additional Load
32 mm dia 2.5 mm thick 27.56
13 Market Rates - Diesel Genrator Set With AMF Panel - 3 Phase, 433V,50HZ - 500 KVA As Per CPCB Norms 500 KVA Diesel Genrator Set
For Additional Load
500KVA DG Diesel Genrator Set With AMF Panel 1
14 Electrical SR - Vol 6 (2023-24) - SR. No: 1.6.2 - E Pg. 379 - Digging of Pit for providing GI Pipe type Earthing Hard Soil
For Additional Load
15 Electrical SR - Vol 6 (2023-24) - SR. No: 12.58.10 - E Pg. 471 - Supplying fixing and wiring earth electrode for grounding of lifts,transformers,DG sets etc.using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and char coal from the bottom of the CC chamber.Theconnectionfromthe electrode is to be established through GI strip using GI bolts and nuts. 50 x 6 mm Copper strip
For Additional Load
50 x 6 mm Copper strip 1 25
16 Electrical SR - Vol 6 (2023-24) - SR. No: 12.60.3 - E Pg. 472 - Supplying & Fixing Chemical earthling for grounding.Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits,superiorFault conductioncapacity, non toxic,weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound
For Additional Load
Using 10ft. Copper bonded rod with backfill compound 8
17 Vol 1 (2023-24) - SR. No: 1.14.1 - Pg. 8 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
For Additional Load
Earth Excavation for Laying of Cable 1 140 0.9 1.2
18 Vol 1 (2023-24) - SR. No: 1.10 - Pg. 7 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications
For Additional Load
Earth Excavation for Laying of Cable 1 140 0.9 1.2
19 Vol 2 (2023-24) - SR. No: 6.2 - Pg. 13 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
For Additional Load
20 Vol 2 (2023-24) - SR. No: 8.1.2 - Pg. 41 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
For Additional Load
21 Vol 5 (2023-24) - SR. No: 9.1.2 - Pg. 95 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 75mm dia
For Additional Load
HDPE Grade PE80-PN6.0, 75mm dia 140
22 Electrical SR - Vol 6 (2023-24) - SR. No: 1 - E Pg. 236 - Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure.
For Additional Load
Jelly Spreading (20-25 mm) 46
23 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.19 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 500-630 A 50 kA
For Additional Load
24 Electrical SR - Vol 6 (2023-24) - SR. No: 5.40.4- E Pg. 437 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips
For Additional Load
600 A 4 x 75 x 10 mm Aluminium Strips 4
25 Electrical SR - Vol 6 (2023-24) - SR. No: 5.41.2 - E Pg. 437 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm
For Additional Load
26 Electrical SR - Vol 6 (2023-24) - SR. No: 5.42.1- E Pg. 437 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG
For Additional Load
27 SR - Vol 2 (2023-24) - SR. No: 11.58 - Pg. 95 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in-charge. (Made of G.I. wire of dia 4 mm) Ground leveling
For Additional Load
Chain link fabric fencing mesh 1 500
28 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.16 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 36 kA
For Additional Load
29 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.13 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 25 kA
For Additional Load
30 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.9 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA
For Additional Load
31 Electrical SR - Vol 6 (2023-24) - SR. No: 5.40.2 - E Pg. 437 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips
For Additional Load
250 A 4 x 30 x 10 mm Aluminium Strips 8
32 Civil SR - Vol 1 (2023-24) - SR. No: 1.3 P.No.5 - Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm asperdrawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
For Levelling Ground
33 Civil SR - Vol 1 (2023-24) - SR. No: 1.11 P.No.7. - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
For Levelling Ground
34 Civil SR - Vol 3 (2023-24) - SR. No: 4.1.401.A.II P.No.23. - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
For Levelling Ground
ASSISTANT ENGINEER ESTATE OFFICER
KMCRI HUBBALLI KMCRI HUBBALLI
ಕರ್ನಾಟಕ ವೈದ್ಯಕೀಯ ಮಹಾವಿದ್ಯಾಲಯ ಮತ್ತು ಸಂಶೋಧನಾ ಸಂಸ್ಥೆ ಆವರಣದಲ್ಲಿ ಹೆಚ್ಚುತ್ತಿರುವ ಮೆಡಿಕಲ್ ಉಪಕರಣಗಳಿಗೆ ವಿದ್ಯುತ್ ಪೂರೈಸಲು ಹೆಚ್ಚುವರಿಯಾಗಿ 750 ಕೆವಿಎ ಟ್ರಾನ್ಸಫರ್ಮರ್ ಮತ್ತು 750 ಕೆವಿಎ ಡಿಜಿ ಸೆಟ್ ಅಳವಡಿಸುವ ಕಾಮಗಾರಿ
Sl. No. Description of work Unit Basic Rate 2023-24 S/R Area Weightage at 5% Total
1 Electrical SR - Vol 6 (2025-26) - SR. No: 39.03 - E Pg. 64 - Compact RMU (VCB/SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC 62271/IS-3427 5 Way RMU, 2 OD + 3 VL (One Incomer + Three Breakers + One Outgoing) Unit 960191
2 Electrical SR - Vol 6 (2025-26) - SR. No:23.01 - E Pg. 108 - Transporting of RMU Transporting RMU (Coventional) unit from store to work spot including loading, unloading. (No separate crane charges) 5 Panel No 19031
3 Electrical SR - Vol 6 (2025-26) - SR. No:23.07 - E Pg. 109 - Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., 1 Panel Per Panel 856
4 Market Rates - Distribution Transformer - 3 Phase, 11kV/433V - 500 KVA Copper Winding, both side bushings (Any Make approved by HESCOM) 500 KVA Distribution Transformer Each 2000000
5 Electrical SR - Vol 6 (2025-26) - SR. No:36.01 - E Pg. 62 - 11kV, 3 Core HTUG XLPE Insulated Cables as per IS-7098 (Part-2) 2011 with following parameters & as per BESCOM Requirements 95 Sqmm, (54 GI Wires - 2.5 mm Dia) KM 991366
6 Electrical SR - Vol 6 (2025-26) - SR. No: 21.01 - E Pg. 107 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x95 to 150 Sqmm KM 54661
7 Electrical SR - Vol 6 (2025-26) - SR. No:45.01 - E Pg. 70 - 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm Set 8976
8 Electrical SR - Vol 6 (2025-26) - SR. No: 32.19 - E Pg. 58 - 1.1kV LTUG XLPE Insulated Cables as per IS-7098 (Part-1) with following parameters & as per BESCOM Requirements 300 Sqmm, 3.5 Core KM 1380083
9 Electrical SR - Vol 6 (2025-26) - SR. No: 21.08 - E Pg. 107 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 300 to 400 Sqmm KM 30450
10 Electrical SR - Vol 6 (2025-26) - SR. No: 22.12 - E Pg. 108 - Heat shrinkable Straight Through Joint 300 to 400 Sqmm Set 508
11 Electrical SR - Vol 6 (2023-24) - SR. No:1.9.3- E Pg. 420 - Supplying PVC flexible conduit pipe ....mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or raw plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 32 mm MTR 29
12 Electrical SR - Vol 6 (2023-24) - SR. No: 1.3.3- E Pg. 419 - Supplying heavy gauge PVC Conduit Pipe .... dia .......mm thick with suitable size bends,metal junction boxes adhesive paste etc.,by groove cutting in the wall and ixing by bracing U or J hooks and cement plaster in gup to the wall surface and run with18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thick MTR 99
13 Market Rates - Diesel Genrator Set With AMF Panel - 3 Phase, 433V,50HZ - 500 KVA As Per CPCB Norms 500 KVA Diesel Genrator Set Set 4000000
14 Electrical SR - Vol 6 (2023-24) - SR. No: 1.6.2 - E Pg. 379 - Digging of Pit for providing GI Pipe type Earthing Hard Soil Per pit 2990
15 Electrical SR - Vol 6 (2023-24) - SR. No: 12.58.10 - E Pg. 471 - Supplying fixing and wiring earth electrode for grounding of lifts,transformers,DG sets etc.using 40mm dia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and char coal from the bottom of the CC chamber.Theconnectionfromthe electrode is to be established through GI strip using GI bolts and nuts. 50 x 6 mm Copper strip Mtr 2169
16 Electrical SR - Vol 6 (2023-24) - SR. No: 12.60.3 - E Pg. 472 - Supplying & Fixing Chemical earthling for grounding.Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits,superiorFault conductioncapacity, non toxic,weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound Kit 8494
17 Vol 1 (2023-24) - SR. No: 1.14.1 - Pg. 8 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum 102
18 Vol 1 (2023-24) - SR. No: 1.10 - Pg. 7 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications Cum 160
19 Vol 2 (2023-24) - SR. No: 6.2 - Pg. 13 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum 7978
20 Vol 2 (2023-24) - SR. No: 8.1.2 - Pg. 41 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm 241
21 Vol 5 (2023-24) - SR. No: 9.1.2 - Pg. 95 - Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 75mm dia MTR 245
22 Electrical SR - Vol 6 (2023-24) - SR. No: 1 - E Pg. 236 - Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure. m³ 1773
23 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.19 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 500-630 A 50 kA Each 41899
24 Electrical SR - Vol 6 (2023-24) - SR. No: 5.40.4- E Pg. 437 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips MTR 5625
25 Electrical SR - Vol 6 (2023-24) - SR. No: 5.41.2 - E Pg. 437 - Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm MTR 395
26 Electrical SR - Vol 6 (2023-24) - SR. No: 5.42.1- E Pg. 437 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG cm2 0.5
27 SR - Vol 2 (2023-24) - SR. No: 11.58 - Pg. 95 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer in-charge. (Made of G.I. wire of dia 4 mm) m2 803
28 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.16 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 36 kA Each 28216
29 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.13 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 25 kA Each 21391
30 Electrical SR - Vol 6 (2023-24) - SR. No: 5.15.9 - E Pg. 434 Supplying and fixing Moulded Case Circuit Breaker(MCCB)over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators,handle and wiring complete.Protection of Over load and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as perIS/IEC60947-2.(Icu=100%lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/OverLoad. For Microprocessor MCCBS Facility for segregatinPriorityandNon-Priority loads must be available in the MCCB.MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA Each 8487
31 Electrical SR - Vol 6 (2023-24) - SR. No: 5.40.2 - E Pg. 437 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips MTR 3435
32 Civil SR - Vol 1 (2023-24) - SR. No: 1.3 P.No.5 - Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm asperdrawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Cum 177
33 Civil SR - Vol 1 (2023-24) - SR. No: 1.11 P.No.7. - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum 433
34 Civil SR - Vol 3 (2023-24) - SR. No: 4.1.401.A.II P.No.23. - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Cum 2560
ASSISTANT ENGINEER ESTATE OFFICER
KMCRI HUBBALLI KMCRI HUBBALLI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
KW-3 KMCRI 750KVA.doc
Tender Document • 2.65 MB
Check list 750KVA.xlsx
Instructions to Tenderers • 0.01 MB
Estimate 750KVA.xls
Instructions to Tenderers • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .