Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹23.9 L+₹1.7 L (7.63%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹24.4 L+₹2.2 L (9.78%)Rejected-Finance | L3 | Rejected-Finance Non bonafide tender | |
| 4 | L4₹28.1 L+₹5.9 L (26.5%)Rejected-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹30.6 L+₹8.4 L (37.6%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
24 Nov 2020, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
OUTSOURCING SERVICES FPR OPERATION AND MAINT OF ELECTRIC, WATER SUPPLY INSTALLATIONS,INTERNAL ELECTRIFICATION, TRANSFORMER OIL FILTRATION AND SERVICING OF VCBs / ACBs AT MTRDC (TECHNICAL AREA) AT BANGALORE
2020_MES_369568_1
GE(I) R ND D (WEST)/BAN/37 OF 2020-21 8834E8
Open Tender
Manpower Supply
Item Rate
330 days
Bengaluru
Class and category as per NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹57,000
Yes
15 Dec 2020
16 Oct 2020
1 Dec 2020
17 Oct 2020
24 Nov 2020
10 Nov 2020
17 Oct 2020 - 9 Nov 2020
Amount
SCHEDULE 'A' PART - I (OUTSOURCING SERVICES)
Providing services for operation, maintenance of electric supply and water supply installations including internal electrification of buildings at MTRDC Technical Area by deploying skilled, qualified persons having experience in handling similar equipments/services and periodical maintenance to equipments, maintaining log sheets, complaint register, maintenance register, breakdown register etc complete. The scope of work/services to be provided by contractor in each shift and number of shifts in day for MTRDC Technical Area are enumerated below and as specified in particular specification in following areas :- MTRDC Technical area at HMT Complex (Main Building and JC Bose Building) in general shift (excluding Sundays and Holidays), Shift timings from 0830 Hours to 1730 Hours with Electrician - 02 Nos and Helper - 1 No per shift NOTES :- (i) Details of equipment/services to be maintained are indicated as appendices in PS. (ii) Various items required for replacement are regulated by the department except those given under relevent items of schedule ‘A’ as supply only. However replacement cost of these items are deemed to be included in this item. (iii) The Items mentioned under relevent items of schedule ‘A’ shall be supplied by the contractor as and when required at site and the same shall be measured and paid under relevant items of Sch 'A' Part - II. (iv) Tenderer shall maintain relevant slips of complaints attended and materials used duly signed by users and any other documents as signed by dept and cost of the same is deemed to be included in the rate quoted.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., (v) T&P, HT fuse wire and safety gear required for attending to the complaints will have to be arranged by the tenderer at no extra cost to the department. Attention is drawn to latest minimum fair wages payable as notified (time to time) by Govt Of India / State Govt / Local body whichever is higher, including taxes as applicable and quote their rates accordingly. Contractor shall not have any claim on account of misunderstanding / under quoting in this regards. vi) Tenderer shall arrange insurance to his work-men and relevant proofs of the same shall be submitted to the department as and when demanded, the cost for the same is deemed to be included in the rate quoted. Responsibility of compliance of labour regulations in force lies with the tenderer. The provision of statutory laws relating to minimum wages, EPF, EDLI, ESIC, Bonus, GST, Cess & other levies payable shall be strictly adhered to by the contractor. The Contractor shall produce proof of wages, EPF, ESIC, Bonus paid against the respective workmen while claiming payments. vii) Absent from duty of technician is not permissible as E&M services are essential in nature. However, the absence will invite penalty as specified in tender and recovery shall be done through recovery statement from the payment due to Contractor. The tenderer will have no claim whatsoever on this account and decision of Accepting officer in this regard will be final and binding.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., viii) Tenderer shall work out and quote the rates under Col 5, Col 7, Col 9, Col 11 & Col 13 for each item / sub items. Rate quoted under Col 9 (overheads and Profits) shall also deemed to include for consumable items, uniforms, stationery charges, etc., required for proper operation and maintenance of equipments. viii) Bid submitted by Tenderer under following stipulations shall be treated as non - bonafide / invalid / disqualified and such bids will not be considered for acceptance and in such case the lowest bidder shall be determined from amongst the valid / bonafide bids only :- a) Quoting wages under Col 5 against any item / sub-items of BOQ shall not be less than the prevailing minimum rates of wages payable as notified by Govt. of India/ Concerned State Govt / Local body whichever is higher. b) Quoted rate under Col 7 i.e., Bonus, shall not be less than Minimum payable (8.33%) and shall be based on actual payment basis. c) If quotes under Col 9, OH & Profits, Consumable items, uniforms, stationery charges, etc., quotes "Nil" or "Zero" consideration d) ESIC % under Column 13 is @ 3.25% subject to Salary less than 21,000/- as per instructions in vogue x) In case Contractor is liable to pay EPF, % quote under Column 11 shall not be less than % applicable as per EPF & MP Act and its latest notifications / amendments. xi) Quoted rates shall deemed to be inclusive of all taxes, cess, levies as applicable including GST. x) Any variation in minimum wages, liability of EPF, ESIC, EDLI, BONUS, LWC, GST shall be adjusted from re-imbursement / recovery as specified in Special Conditions here-in-after. The prevailing wages / Contribution prevailing on the bid submission end date shall be considered as base for adjustment / re-imbursement as specified here-in-after.
Notes for Sl Item No 1.00 to 2.02 (including Sub Items) Contd., xi) Exemptions / limiatations, if any shall not be considered while quoting rates, EPF, ESIC, BONUS, LWC as the same shall be calculated during actual contribution payable depending upon the salary of the individual based on the number of days engaged in the work. xii) Contractor’s attention is invited to Labour Wages Act with regards to payment of wages to the individuals engaged under this work. Contractor shall make the payments to their staff / employees by Cheque or through NEFT in their Bank Account, and the particulars of same shall be submitted to the department while claiming any payment. No payments will be made, unless proof of payment of wages through bank account is submitted by the Contractor/firm while claiming bills. xiii) The wages, / contribution towards EPF, EDLI, ESIC, Bonus shall be paid by the GE in RAR / Final bill only after submission of valid and authentic document in support of proof of payment / contribution of requisite amount to the workmen by the Contractor. In case, the Contractor fails to submit proof of payment made to Workmen, no payment will be made by Department. xiv) Payment in respect of any item / sub-item of BoQ in RAR / Final bill towards the wages, EPF, EDLI, ESIC, Bonus shall be made on the actual amount paid to the Workmen by the Contractor, subject to maxium of the rate quoted under respective heads, plus his quoted OH&P & LWC and no extra claim by the Contractor shall be admissible in this account. In case, Contractor pays less than quoted rates, payments will be made on the actual amount paid by the Contractor plus his quoted OH&P & LWC and no extra claim by the Contractor shall be admissible in this account and onus of responsibility of violation of respective Acts rests with Contractor.
Rate for Electrician per Shift
Rate for Helper per Shift
All as per Serial item No 1.00 here-in-above, but for additional manning hours for operating beyond the period under Sl Item No 1.00 here - in - above, i.e., after 1730 hours, and for operating on Sundays / Holidays if required and specifically orders by Engineer-in-Charge / GE / Lab Director.
Rate for Electrician per Hour
Rate for Helper per Shift
Description of Work / Item(s)
Amount
SCHEDULE 'A' PART - II (SUPPLY OF MATERIALS, MAINTENANCE AND REPAIRS
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 1.5 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed, multi-stranded heavy duty copper conductor cable of 2.5 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed multi-stranded heavy duty copper conductor cable of 4 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, PVC unsheathed multi-stranded heavy duty copper conductor cable of 6 sq.mm size, FR grade, complete all as specified and directed.
Supply only PVC insulated, flexible copper cable, 23/0.0052, 3 core, 230 volts, complete all as specified and directed.
Supply only switch piano, flush type, 5/6 Amps single pole, 230 V, one way, complete all as specified and directed.
Supply only calling bell, ding-dong type, working on AC, 230 V, single phase, complete all as specified and directed.
Supply only bell push, single pole, flush type, 230 V, 5 Amps, complete all as specified and directed.
Supply only switch socket outlet, 5 pin, 5 A, 240 V, 50 Hz, flush type, complete all as specified and directed.
Supply only switch socket combination, 2-in-1, 6/16 Amps 5 pin, complete all as specified and directed.
Supply only fan capacitor of 2.5 mfd for ceiling fan, single phase, 230 V, complete all as specified and directed.
Supply only fan capacitor of 4 mfd for exhaust fan, single phase, 230 V, complete all as specified and directed.
Supply only ceiling fan clamps for fixing of ceiling fans with rubber bushings, complete all as specified and directed.
Supply only PVC, ceiling rose three terminals white bakelite type complete all as directed.
Supply only plug top, 3 pin, 15 Amps, 240 V, 50 Hz, complete all as specified and directed.
Supply only MCB, SP, 230 V, 32 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB SPN, 230 V, 16 / 20 Amps current rating, 'C' series, 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB TPN 63 Amps, 415 Volts, AC, 50 Hz, 10 kA, breaking capacity, complete all as specified.
Supply only MCB TP 100 Amps, 415 Volts, AC, 50 Hz, 10 kA, breaking capacity, complete all as specified.
Supply only Isolator four pole, 415 volts, 63 Amps, "C" series , 10 KA breaking capacity complete all as specified and directed.
Supply only Isolator four pole, 415 volts, 100 Amps, "C" series , 10 KA breaking capacity complete all as specified and directed.
Supply only PVC casing/caping of 20mm size, complete all as specified and directed.
Supply only PVC casing/caping of 25 mm size, complete all as specified and directed.
Supply only rigid non metalic PVC conduit of size 25 mm dia medium grade ISI marked complete all as specified.
Supply only rigid non metalic PVC conduit of size 20 mm dia medium grade ISI marked complete all as specified.
Supply only LED bulb 9/11 W all as specified and as directed.
Supply only angle holder suitable for LED lamp 9/11 W, complete all as specified
Supply only side holders suitable for tube light fittings, bakelite type, complete all as specified and directed
Supply only PVC gang boxes suitable for 15 Amps sockets all as specified.
Supply only PVC gang boxes suitable for 5 Amps sockets all as specified.
Supply only LED tube Rod with light fitting, 18 Watt with high lumen output, environmental friendly, energy efficient LED, electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, Ultra bright glass, with very high efficacy suitable for installation in existing T8 fitting with G13 lamp holders, complete as per Cat No CRYSTAL 1213T8DSTL18WLED865SGLASS of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only wall mounted LED tube light fitting with lamp, 9 Watt, 2 ft, with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser, polyestyer louver with 9 watt LED tube & integrated electronic driver 9 W fitting as per cat No LUMILINEBS9WLED830SPCWH of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only wall mounted LED tube light fitting with lamp, 18 Watt 4 ft length with high lumen output, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, complete with diffuser, polyestyer louver with 18 watt LED tube & integrated electronic driver 18W, fitting as per cat No LUMILINEBS18WLED830SPCWH of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply only, down lighter fitting, Supply and fix, 36 / 40 W, LED, down lighter fitting, efficient luminaire, 2'x2', Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for ceiling, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 120 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No.VENUSNEOHE2X2PLR18-42WLED857MOD of Havells or techno-commercially equivalent model in Philips / CG / Syska complete with all accessories pre-wired, all as specified and as directed.,
Supply only, down lighter fitting, Supply and fix, 34 W, LED, down lighter fitting, efficient luminaire, 2'x2', Ultra modern designed architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for ceiling, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > 120 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH , 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable, including lamps complete all as specified and directed. MAKE:- Cat No.PLUTOSURFACE2X2PLS34WLED857S of Havells or techno-commercially equivalent model in Philips / CG / Syska complete with all accessories pre-wired, all as specified and as directed.,
Supply only, post top lantern light fitting, Supply and fix 25 W, LED Post top lantern light fittings with lamp 25 W,with high lumen output, environmental friendly, energy efficient LED, with lamps and accessories, IP 65 protection, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings made of powder coated housing, enclosed with glass cover in frame, connecting with and including twin twisted copper wire 1.5 sq mm, light fitting conforming to Cat No RUBYPT25WLED757PSYMTOPC of Havells or techno commercially equivalent approved model complete with all accessories and lamp complete all specified and as directed.
Supply only LED street light fittings with lamp, 48 W, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP65 protection and impact resistance of IK07 with high lumen output, with and including lamp and accessories, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, intergral drivers, fittings as per Cat No ENDURAPEARLNEOSL48WLED757SASYTOPC of make Havells or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply metal clad plug 2P+E , 20 Amps , 240 Volts all as directed.
Supply metal clad socket with cap & chain 2P+E, 20 Amps, (without MCBs), 240 Volts all as directed.
Supply only HBC fuse link bolted type (central type)125 to 200 Amps all as directed.
Supply only HBC fuse link -Knife (din) type 125 Amps all as directed.
Supply only, MPP capacitors for non-linar load, heavy duty, cylindrical (gas filled), 440 Volts, 5 KVAR of various capacities and connecting complete including taking out un serviceable capacitors complete all as directed.
Supply only, MPP capacitors for non-linar load, heavy duty, cylindrical (gas filled), 440 Volts, 25 KVAR of various capacities and connecting complete including taking out un serviceable capacitors complete all as directed.
Supply only Fluorescent tube rod 36/40 watts , 230 volts suitable for fixing in tube light fittings complete all as specified.
Supply only Fluorescent tube rod 18/20 watts , 230 volts suitable for fixing in tube light fittings complete all as specified.
Supply only tube light starter 230 Volts, single phase suitable for 20/40watts tube light fittings complete all as specified.
Supply only Electronic Ballast 1 x 36/40 Watts, 230 Volts suitable for fixing in tubelight fittings complete all as specified.
Supply only electronic choke 2 x 36 W for CFL fitting, 230V, complete all as specified and directed.
Supply only copper choke 36/40 W, 230 V, suitable for fixing in tube light fitting, complete all as specified and directed.
Supply only copper choke 18/20 W, 230 V, suitable for fixing in tube light fitting, complete all as specified and directed.
Supply only CFL 18 Watt, 2 pin diagonal type (Non retrofit type) all as directed.
Supply only CFL 36 Watt , 4 pin all as directed.
Supply only holder suitable for 2/4 pin CFL all as directed.
Taking down unserviceable, ceiling fans, depositing same in AGE E/M Storeyard, Supply and fix, Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5 mfd, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, writing MES number on ceiling fan motor complete all as specified and directed. MAKE:- Auro Plus of Crompton Greaves or techno-commercially equivalent model in BAJAJ / HAVELLS / USHA
Taking down existing unserviceable exhaust fan of any sweep with blade and louvers and depositing same in AGE E/M store yard, Supply and fix, exhaust fan 230/240 Volt, 50 Hz, single phase, AC supply, 300 mm sweep with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- Model: Ventil Air-DSP of Havells or techno-commercially equivalent model in Almonard / Bajaj.
Taking down existing unserviceable exhaust fan of any sweep with blade and louvers and depositing same in AGE E/M store yard, Supply and fix, exhaust fan 230/240 Volt, 50 Hz, single phase, AC supply, 450 mm sweep with louvers complete with metal body powder coated with protective steel bird guard on wall of building with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- Model: Ventil Air-DSP of Havells or techno-commercially equivalent model in Almonard / Bajaj.
Taking down existing ceiling fan/exhaust fan of any sweep with blade and down rods etc from ceiling/walls by unscrewing the nut bolts, opening the split pin and keeping in safe custody repairing and re-fixing the same after repairs, preparing the surfaces and spray painting with two coats of synthetic enamel paint, writing MES No. complete all as specified and as directed. NOTE: Repairs shall be measured and paid for separately under respective items.
Disconnecting, taking down ceiling fan, with blade, inspecting motor assembly, replacing burnt out capacitors, split pins, etc, servicing, cleaning, greasing, removing all deposited materials, checking for smooth functioning, re-assembling the same complete all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 6 Nos, 2.5 mfd capacitor - 1 No, shall deemed to include in this item.
Rewinding of ceiling fan motor with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Dismantling / opening of exhaust fan of 300/450mm sweep motor assembly inspecting all dismantled parts repairing replacing the unserviceable parts and following components with new ones including oiling greasing reassembling motor assembly all as specified and directed. NOTE:- Cost of PVC capacitor bracket -1 No, split pins - 1 Nos, & 2 mfd Capacitor - 1 No, shall be included in this item.
Rewinding of exhaust fan motor 300/450 mm sweep with super enameled copper winding wire of suitable gauge after cutting and removing burnt winding, including varnishing of new winding and drying up carefully all as specified and directed.
Excavation in trenches in hard / dense soil not exceeding 1.5 metre wide not exceeding 1.5 metre in depth; for laying of cables not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed .
Returning filling with excavated soil, including spreading, leveling , watering and well ramming in layers not exceeding 25 cm in soil as directed .
Removing of excavated soil to a distance not exceeding 50 m & depositing where as directed at a level not exceeding 1.5m above starting point all as specified and as directed.
Supply and lay cable XLPE insulated armoured LT cable 1100 volts grade of size 10 Sq mm 2 core, in trenches/ on walls / poles including suitable MS clamps for fixing if required, connecting, testing and commissioning including taking down or pulling out the existing unserviceable cable complete all as specified and as directed Notes:- Earthwork, sand filling, brick protection, lugs shall be measured and paid separately under relevant items of this schedule.
All as per item 65 here in before but of cable 35 sq mm 3.5 core
All as per item 65 here in before but of cable 70 sq mm 3.5 core
All as per item 65 here in before but of cable 400 sq mm 3.5 core
Taking out old unserviceable joints, Supply, jointing new outdoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 16 to 185 sqmm, testing, complete all as specified and as directed
Taking down old security light, timer switch box 0.80 m x 0.80 m x 0.30 m, fabricated out of 16 SWG CRCA sheet, powder coated, with mounting, locking arrangement, complete and Supply and fixing Timer switch box fabricated out of 16 SWG CRCA sheet with mounting and locking arrangement duly powder coated consisting of following :- (a) Digital timer, 65 A, 3 P, 230 V, all as per Indo Asian Cat Part No. TL065AB0 of Indoasian or techno commercially equivalent in other makes specified - 01 No (b) Power contactor 63 Amps Make: L&T/Havells/INDOASIAN- 01 No. (c) Connector 100 Amps 230 volts - 03 Nos. (d) MCCB TP 63 Amps 415 volts - 01 No. (e) Control fuse 2 Amps - 01 No.
Supply only LED type indicator lamps 3 phase with RYB colours (set of 3) complete all as specified and as directed.
Disconnection the power supply of boards/boxes, preparing the surfaces and applying one coat of synthetic enamel paint on VCBs, LT panel boards, feeder pillar boxes, etc over 10 cm width or girth and re-connecting power supply and applying paint complete all as specified and as directed.
Dismantling old steel tubular pole, RCC pole of any length, Supply, erect and connecting, Steel tubular swaged poles type 410 SP-22 (9 metres long), ISI marked, complete with CI base plate and finial taper plug, bolts, nuts & screws complete all as specified and directed. Note: Excavation and earthwork, PCC foundation, coping of poles shall be measured and paid separately under respective item. complete all as directed.
Supply only MCCB, 4 Pole, 400 Amps, 35/36 KA breaking capacity, 50 Hz, 415 V AC, thermal magnetic release trip unit, with suitable lugs, complete all as specified.
Supply only MCCB, 4 Pole, 250 Amps, 35/36 KA breaking capacity, 50 Hz, 415 V AC, thermal magnetic release trip unit, with suitable lugs, complete all as specified.
Supply only MCCB, 4 Pole, 200 Amps, 25 KA breaking capacity, 50 Hz, 415 V AC, thermal magnetic release trip unit, with suitable lugs, complete all as specified.
Supply only MCCB, 4 Pole, 100 Amps, 25 KA breaking capacity, 50 Hz, 415 V AC, thermal magnetic release trip unit, with suitable lugs, complete all as specified.
Supply only MCCB, 4 Pole, 125 Amps, 25 KA breaking capacity, 50 Hz, 415 V AC, with suitable lugs, complete all as specified.
Supply only MCCB, 3 Pole, 63 Amps, 16 KA breaking capacity, 50 Hz, 415 V AC, with suitable lugs, complete all as specified.
Supply only MCCB, 3 Pole, 100 Amps, 16 KA breaking capacity, 50 Hz, 415 V AC, with suitable lugs, complete all as specified.
Calibration of relays of HT 11 KV, VCB/OCB, comprising of over current and earth fault at HT systems through primary and secondary injection method and testing complete of control relays panels panels complete all as directed
Servicing and painting of two / four pole structure consisiting of poles, rolled steel joists mild steel channels and supports with one coat of aluminium paint including colour code for RYB to indicate the colour code for body earthing and lightning arrestor complete including taking proper shut down, greasing the GOD switch, tightening of all bolts & nuts, replacement of ACSR conductor, PVC sleeves, wornout lugs, PG clamps and HT fuses in the structure as required at site including two coats of white wash for masonary plat form, one coat of synthetic enamal paint for weld mesh, removing of weeds / plants inside the yard and cleaning the entire premises complete all as specified and as directed.
Servicing of HT VCB's of 800 amps capacity after removing contact unit from HT panel including cleaning, greasing of all moving parts, tightening of bolt and nuts and removing carbon deposits and sludge including adjusting spring tensions, tightening all cable interconnections, blowing hot air to remove moisture content from the unit compactment, including re-fixing, testing and commissioning complete all as specified and as directed.
Servicing of LT ACB's of capacity 630/800 amps complete with microprocessor relay by with-drawing ACB from cabint compartment including cleaning, greasing of all moving parts, tightening of bolt and nuts and removing carbon deposits and sludege including adjusting spring tensions, tightening all cable interconnections, blowing hot air to remove moisture content from the unit compartment, including re-fixing, testing and commissioning complete all as specified and as directed.
Supply only, auxillary contact 10 A capacity suitable for ACB 630/800 Amps with 2 NO + @NC coil voltage 220 V, AC, 50 Hz complete with accessories after taking down old one all as specified and as directed.
Supply only, shunt release suitable for ACB 630 A to 800 A, 3-phase, 415 V, 50 Hz complete after taking down old one all as specified and as directed.
Supply only, under voltage release suitable for ACB 630 A to 800 A, 3-phase, 415 V, 50 Hz after taking down old one complete all as specified and as directed.
Supply only, earth fault release suitable for ACB 630 A to 800 A, 3-phase, 415 V, 50 Hz after taking down old one complete all as specified and as directed.
Material and labour for plain Cement Concrete (1:3:6), type C1, using 20 mm graded stone aggregates for coping of poles / plinth blocks of HT poles etc., including necessary form work and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for, Plain cement concrete (1:4:8), type D2 ,using 40 mm graded stone aggregates for foundation of poles complete all as specified and directed.
Demolishing old earthing pit, and providing new earthing pit with material and labour for earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6.3 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth strip of 32 x 6 mm, by means of bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 20 mm bore (light grade) connected to earthing test point all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in cement concrete (1:3:6), type C1 , manhole cover with RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTES :- (i) The quoted rate deemed to include earth strip and protection pipe up to 7.5 metre from earth plate / earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Pacific Enterprises
SREE VARU ELECTRICALS
M/S SRI BALAJI ENTERPRISES
B5BUILDING SOLUTIONS
M/S Sneha Enterprises
SREE VARU ELECTRICALS
Solar Electricals and Electronics
M/S SRI BALAJI ENTERPRISES
M/S Sneha Enterprises
B5BUILDING SOLUTIONS
Bidder Name
M/S SRI BALAJI ENTERPRISES
M/S Sneha Enterprises
SREE VARU ELECTRICALS
Solar Electricals and Electronics
Pacific Enterprises
B5BUILDING SOLUTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .