Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 | GOHANA | SONIPAT | HARYANA | 131301 | L1 | Accepted-AOC work allotted |
Tender Value
₹16.0 L
EMD Value
₹32,000
Closing Date
10 Sept 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer, Elect. Division PWD BandR Br., Karnal (0184-2265696)
Construction of PWD Rest House main building and Subordinate Rest House with 2 Nos. 550 sft. Quarter (Gplus1) in village Barota at Gohana in Sonepat District (CM Announcement code No. 23612 dated 16.09.2018) (Pdg. EI only) Recall
2021_HRY_181738_2
PWD Rest House Barota (EI only)
Open Tender
Electrical Works
Works
300 days
Sonipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹32,000
18 Jan 2022
20 Aug 2021
10 Sept 2021
20 Aug 2021
10 Sept 2021
20 Aug 2021
120 days
Amount
23.1.1.3 COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C
23.1.2.3 Wiring for Twin control light point with 2 nos, 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C
23.1.4.3 Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group C
23.1.5.3 Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group C
23.1.6.1 Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
23.1.6.2 1 run of Size 2.50 Sqmm(1.1.80mm)
23.1.6.6 2 run of Size 1.50 Sqmm(1/1.40mm)
23.1.6.9 3 run of Size 1.50 Sqmm(1/1.40mm)
23.2.1.3 COPPER WIRING WITH MODULAR SWITCHES IN MS CONDUITS (SURFACE/RECESS) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C
23.2.2.3 Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick MS conduit pipe. Group C
23.2.4.3 Wiring in MS conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C
23.2.5.3 Wiring in MS conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLs copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C
23.5.6.5 COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)
23.6.6.1 MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia.
23.6.6.3 MS Pipe of 32 mm dia.
23.7.6.2 PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.
23.7.6.3 PVC pipe of 32 mm dia.
23.8.1.1 FITTING AND ACCESSORIES Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Switch 5 amp. on existing sheet.
23.8.1.2 Wall socket 5 amp on existing sheet.
23.8.1.7 Electric buzzer 220/230 volts A.C. Bakelite with double coil.
23.8.1.12 Bakelite angle/straight button holder large size.
23.8.1.13 Socket size rotary step type Electronic regulator for A.C. ceiling fan
23.8.4 Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
23.8.10.4 Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules
23.8.11.1 Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch
23.8.11.4 5 amp Socket
23.8.11.6 Bell Push
23.8.11.7 step type Fan Regulator 2 modules 300 watt
23.8.11.8 Telephone Socket outlet modular type
23.8.11.9 T.V. Socket outlet modular type
23.8.11.10 Blanking plate
23.8.11.11 RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type
23.8.11.12 USB Charger, 1000mA, 5V, 1 Module
(For Non residential use only) 23.9 Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
23.11 Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless stell wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as required
23.20 Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.
23.21 Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required
23.22.1.1 MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Double pole MCCB 16 to 63 Amp, 25KA
23.22.1.9 4 pole MCCB 6 amp to 100 amp,25 KA
23.22.1.11 4 pole MCCB 200 to 250 amp, 25 KA
23.22.3.2 Supply and erection of sheet steel enclosures 1pole/ 2 pole/4 pole including providing SP/DP/TP/FP MCB on wall/on existing pedestal complete with necessary connections etc, :- SPN or DP enclosure Suitable for DPMCB
23.22.4.3 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)
23.22.4.7 TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
23.22.4.8 TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing)
23.22.5.1 Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
23.22.5.3 6 amp. to 32 amp Double POLE
23.22.5.7 6 amp. to 32 amp MCB's FOUR POLE
23.22.5.8 40 amp to 63 amp. MCB's FOUR POLE
23.22.6.5 Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. FP RCCB 30mA sensitivity , 40 A
23.22.7 Supply and erection of blanking sheet in existing distribution board.
23.24.1 Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide.
23.24.2.2 Panels/Feeder Pillars having incomers of more than 200 A and up to Four pole 400 A , Base Mounting frame made of ISMC 150*75*5.7 mm
24.1.1 Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
24.1.2 Extra for using salt and char coal/coke for pipe earth electrode as required.
24.1.4 Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
24.1.5 Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
24.1.9 Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
24.1.10 Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
24.1.11 Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
24.1.13 Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop carthing as required.
24.2.7.2 Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 Core
24.2.7.3 25 sqmm to 50 sqmm Cable 2 to 4 Core
24.2.8.3 Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer- in-charge of the work. 10 sqmm
24.5.2.3 MISCELLANEOUS ITEMS S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
24.5.2.4 DWC/HDPE pipe 90/75 mm outer dia/inner dia
NS Item Supply and erection of under ground Aluminum Armoured cable XLPE insulated loose in existing pipe or trenches complete with necessary connection. Make RR / Havells / Polycab. 185 Sqmm 3.5 core
35 Sqmm 4 core
25 Sqmm 4 core
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .