| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | ₹34.0 L Quoted ₹34.6 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹35.5 L+₹85,486.50 (2.47%)Rejected-Finance JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | ₹35.5 L+₹85,486.50 (2.47%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹35.6 L+₹93,765.50 (2.71%)Rejected-Finance BLDG NO 11 88 LAKSHMI BUILDERS UPPADA POST NILAMBUR MALAPURAM KERALA 679334 | MALAPPURAM | KERALA | 679334 | ₹35.6 L+₹93,765.50 (2.71%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹35.7 L+₹1.1 L (3.18%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | ₹35.7 L+₹1.1 L (3.18%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹35.8 L+₹1.2 L (3.38%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | ₹35.8 L+₹1.2 L (3.38%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹39.9 L
EMD Value
₹79,900
Closing Date
7 Oct 2024, 6:00 pmClosed
GE Army trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
SPL REPAIR TO BLDG NO E-03 (BARRACK FOR 43 ORS) AT DSC CENTRE AND PROVN OF INTERLOCKING CEMENT CONCRETE PAVER BLOCKS INFRONT OF BLDG NO XVI OF PAO (ORS) DSC CANNANORE UNDER GE (ARMY) TRIVANDRUM
2024_MES_673737_1
8166/E8
Open Tender
Civil Works
Item Rate
180 days
Kannur
As per tender documents
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹79,900
Yes
2 Dec 2024
10 Sept 2024
14 Oct 2024
10 Sept 2024
7 Oct 2024
25 Sept 2024
10 Sept 2024 - 17 Sept 2024
Amount
Dismantling single layer Mangalore pattern or similar tiles in roofing including ridge tiles complete all as specified and directed.
Dismantling battens for tiles, shingles etc, of any size, spaced exceeding 15 cm including tilting fillets complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in framed work, in any position complete all as specified and directed.
M&L for second class hardwood in scantlings, clean sawn, timber framed, as in rafters and purlins, etc. complete all as specified and directed.
M&L for preparing surfaces of new wood and wood based materials, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
S&F rolled mild steel structural work in tubular, rectangular or square trusses as in pulins, battens, rafters, etc. including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F rolled mild steel structural sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe 410-W (Gde- E- 250) quality-A complete all as specified and directed.
S&F rolled mild steel structural plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410-W (Gde- E- 250) quality-A complete all as specified and directed.
M&L for cement concrete type B0 (1:2:4) (using 12.50 mm graded stone aggregate) as in roof kerbs or mud stops or similar works, rounded or chamfered on edges including necessary formwork complete all as specified and directed.
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new or old untreated steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified & directed.
Demolition of brick or stone /boulder masonry built in cement or cement lime mortar, including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and pre cast concrete articles and removing debris outside MD land all as directed.
M&L for forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work in cement mortar 1:6, complete all as specified and directed.
M&L for making good under cills (or over arches, lintels and bressummers) including all pinning as necessary in cement mortar 1:6, complete all as specified and directed.
M&L for providing pre-cast cement concrete block masonry with solid blocks, exceeding 10cm in width with PCC (1:3:6), type C1, using 20mm graded stone aggregate and set in cement mortar (1:6) complete all as specified and directed.
Taking down cement or cement lime plaster on brick/stone walls or in ceiling surfaces incl racking out joints hacking for key scrubbing down with water etc and removing rubbish outside MD land all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on stone masonry surfaces, finished even and smooth without using extra cement all as specified and directed.
M&L for rendering in two layers 10mm thick with cement mortar (1:4) as finishing coat and 10 mm thick with cement mortar (1:6) as under coat, finishing coat mixed with water proofing compound @ 3% by the weight of cement on stone masonry surfaces or surface other than fair face of brick-work on external surfaces of wall, finishing the surface fair and even complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work (size of grid 605x605 mm) for false ceiling work complete all as specified and as directed.
S&F for hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
M&L for 4 mm thick non-asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws, fixed in jointless finish with jointing compound and jointing tape as per manufacturer instructions complete all as specified and as directed.
M&L for preparation of new non-asbestos fibre cement ceiling board as in ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing debris outside MD land all as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding(but not backing) and rubbish off the premises all as directed.
M&L for 25mm thick PCC 1:2:4, Type B1 (using 20mm graded stone aggregate) as in flooring and finished fair and even complete all as specified and directed.
M&L for 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
M&L for joint free non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 10 mm thick screed bed in cement mortar 1:4 on stone/ brick masonry surfaces, complete all as specified and directed.
M&L for joint free glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
Taking down chowkats with shutters any description exc. 1.5 Sqm but not exc. 4 Sqm each (without taking off shutters from the frame) all as directed.
Taking down chowkats with shutters any description not exc. 1.5 Sqm each (without taking off shutters from the frame) all as directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete as per the directions of Engineer-in-Charge.
S&F mild steel works for flat iron hold fast and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for PCC 1:2:4, type B0 using 12.50mm graded stone aggregate for fixing hold fast, coping, bed block etc including necessary form works all as specified and directed.
M&L for second class hardwood, plain, solid straight chowkats & frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F factory made second class hardwood, plain framed panelled shutter 35mm thick (two panel) with lock rail and panel of 9mm BWP, 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed.
M&L for 2nd class hardwood glazed and skeleton shutters, 30 mm thick open rebated and prepared to receive glass, gauze, etc., without sash bars, chamfered or rounded,mitred and rebated sash bars,any numbers fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); and fitted to chowkats complete all as specified and as directed.
S&F 4mm thick sheet plain glass, ordinary quality and glazing with oil putty in squares not exc 0.50 Sqm in each pane with putty or fixed with beads complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treating ends of posts, backs of chowkats, etc., area tarred exceeding 0.1 sq. m but not exceeding 0.5 sq. m each with tar or coal tar black paint complete all as specified and directed.
S&F 200 mm (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 25 mm dia. Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
S&F 100mm size stainless steel butt hinges medium weight; as per IS 21817 fixed with stainless steel screws all as specified.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
S&F floor door stopper overall length of cover plate 140mm of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor etc complete all as specified and directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed.
M&L preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer complete all as specified and directed.
M&L for preparation of new plastered surfaces and preparing surface even and smooth using 3 mm thick wall care putty (in two coats as per manufacturer instructions) and applying two or more coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer of required shade and colour over a coat of primer complete as per manufacturer's specification complete all as specified and directed.
M&L for complete removal of existing treatment and preparing surface even and smooth using 3 mm thick wall care putty (in two coats as per manufacturer instructions) and applying two or more coats distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer of required shade and colour over a coat of primer complete as per manufacturer's specification complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete as per manufacturer's specification complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of plastered surfaces and applying finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete as per manufacturer's specification all as specified and directed.
Taking up or down 15 mm bore steel tubing and connections complete all as specified and directed.
Taking up or down 20 mm bore steel tubing and connections complete all as specified and directed.
Dismantling of 75mm/ 100mm internal dia. cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, laid in trenches or in floors complete all as specified and directed.
M&L for PVC (SWR) floor trap, plain with 75 mm dia of outlet, grating including jointing with solvent cement complete all as specified and directed.
S&F 15 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
S&F 20 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe complete all as specified and directed.
Cutting chases, pinning in making good to facings where required in brick walls and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and directed.
S&F in repairs Vitreous China urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F in repairs flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern to squatting pattern closet including all joints and making good to the floor complete all as specified and directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 630 x 450 mm, including CI brackets, (but excl. pillar tap) cutting for and pinning in ends of brackets or erecting stand etc complete all as specified and directed.
S&F pillar taps of size 15mm bore dia, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure ,with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
M&L for 32 mm dia. waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F in repairs bib tap of size 15mm bore dia, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15 mm bore dia. stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs shower rose, brass, chromium plated 125mm size with or without swivel joints, fixed to steel pipe or union complete all as specified and directed.
S&F shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/ dense soil complete all as specified and directed.
M&L for hardcore (Broken stone Broken or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8, type D2 using 40mm graded stone aggregate as in sub-base or similar work, complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1, using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and directed.
Excavating in trenches in hard/ dense soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
M&L for PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in benching, surface channels and drains including necessary form works complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L for providing laterite stone masonry with solid blocks, exceeding 10cm in width, set in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in cement mortar 1:6 on fair faces of brick work/ laterite masonry work/ PCC solid block masonry/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Removing excavated materials, soil to a distance exceeding 100 m but not exceeding 150 m depositing where directed at a level 1.5 m above starting point complete all as specified and directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soil obtained from excavation complete all as specified and directed.
Taking down old existing switch socket, light, fan, socket or power point complete including unserviceable fittings such as switches, ceiling roses, pendants, regulators, socktes of any type etc at site and making good the disturbed surfaces of walls, floors, filling up of holes, plastering, white washing, distempering etc matching to the existing etc.
M&L for point wiring for one light point controlled by one way switch with cable 1.5 Sqmm size PVC insulated (unsheathed) 1100 volts grade single core, stranded (multistrand) copper conductor FRLS cable and drawing in and including non-metallic rigid PVC concealed conduit medium grade inclusive of conduit fittings such as bends, tees, reducers etc and galvanised iron sheet steel terminal boxes of size 16 gauge thickness, light switches, sockets with 3 mm thick bakelite laminated sheet brass screws and cup washers including one continuous run of 1.50 Sqmm nominal area solid conductor PVC insulated unsheathed 1100 volts grade single core FRLS cable with solid copper conductor green in colour with wire and connecting to earth dolly complete all as specified and directed.
All as per SI item No. 94.00 here-in-before, but for One fan point controlled by one way switch complete all as specified and directed.
All as per SI item No. 94.00 here-in-before, but for One 3/5 pin socket outlet, 6 Amps, independent, with cables 1.5 sq. mm size complete all as specified and directed.
All as per SI item No. 94.00 here-in-before, but for One 3/5 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5 sq. mm size complete all as specified and directed.
All as per SI item No. 94.00 here-in-before, but for one switch socket outlet, 3/5 pin 15/16 Amp on independent board with 2.50 Sqmm FRLS cable and 2.50 sqmm cable earth continuity wire complete all as specified and directed.
S&F switch piano, flush type single pole, one way 6 Amp complete all as specified and directed.
S&F socket outlet 5 pin, 6 Amp, flush type with safety shutter complete all as specified and directed.
Switch piano, flush type single pole, one way 16 Amp complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 6/16 amp flush type complete all as specified and directed.
M&L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose, 3 terminals PVC/ polycarbonate, isolated body 65x50 mm size complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed.
S&F self ballast LED batten light fitting extruded thermoplastic body with PC diffuser in unique square shape >120 degree wide distribution, including LED light 4 feet 20 Watts of minimum efficacy 120 lumen/ watts LED batten 4 feet, 20 W, CCT 6500 K complete including connectio upto ceiling rose with flaxible copper twin twisted wire including taking down old unserviceable light fittings complete all as specified and directed.
S&F self ballast LED batten light fitting extruded thermoplastic body with PC diffuser in unique square shape >120 degree wide distribution, including LED light 2 feet 10 Watts of minimum efficacy 120 lumen/ watts LED batten 2 feet, 10 W, CCT 6500 K complete including connectio upto ceiling rose with flaxible copper twin twisted wire including taking down old unserviceable light fittings complete all as specified and directed.
S&F surface mounted LED bulk head luminaires 10 watts minimum efficacy 120 lumen/ watts with ABS body & polycarbonate diffuser available in CCT 6000K IP 54, including taking down old unserviceable light fittings complete all as specified and directed.
S&F submain wiring with using two single core 6.00 Sqmm copper multistranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.00 Sqmm copper multistranded conductor PVC insulated and unsheathed (FRLS) earth wire using ISI marked IS 694, 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PVC conduit ISI marked of suitable size including conduit fitting and accessories complete including cutting chases in existing wall of any description built in cement mortar and making good the disturbed surfaces in cement mortar 1:4 and finishing the surface to match with existing surface and finish termonation with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partiton including clamping arrangement as required including taking down submain wiring complete all as specified and directed. NOTE: Two runs of 6.0 sqmm copper cables and one run of 6.0 sq mm copper cable along with white colour PVC conduit with accessories will be measured as one unit length.
S&F MCB SP 6-32 Amps, 240V, breaking capacity 10 KA 'B' series 240 volts, 50 Hz complete all as specified and directed.
S&F MCB SPN 40-63 Amps, 240V, breaking capacity 10 KA 'C' series, 240 volts, 50 Hz complete all as specified and directed.
S&F MCB distribution board, double door, sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral conforms to IS 13032-1991, 4-way with 200 Amps rated bus bar complete all as specified and directed.
S&F MCB distribution board, double door, sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral conforms to IS 13032-1991, 8-way with 200 Amps rated bus bar complete all as specified and directed.
S&F security light bracket with 1.50 mtr long GI pipe 32 mm dia. (medium grade) and fixed along the pole for security light including clamp 02 Nos of size 25x4 mm alongwith nut bolts and washers etc including taking down complete all as specified and directed.
S&F 35 Watts LED street light luminaire integral type, voltage range upto 150V to 270V with one number spare LED drive of the same cap and make. LED street light shall be made up of pressure die-cast aluminium housing with black epoxy polyster powder coating for long life with including connection from overhead conductor to security light fittings with suitable length with Aluminium wire/ cable of size 2.50 Sqmm, 3 core solid conductor including taking down old unserviceable street light fitting complete all as specified and directed. Note:- 1. The luminaire shall be complete IP 66 for optical compartment and control gear Compartment. 2. The optical compartment shall be covered with heat resistant toughned glass for safety. 3. The LED street light shall be top maintainable for easy maint with multiple LEDs with out put of 100 Lum/watt. 4. The LED driver shall be isolated potted type IP-65 with constant current constant voltage topology to ensure optimum driving of LEDs.
S&F LED lamp 15 watts of minimum efficacy 120 lumen/ watt complete all as specified and directed.
Taking down ceiling fan and exhaust fan, sealing cable end, dismantling blades and removing fan and blades to MES store yard complete all as specified and directed.
S&F ceiling fans complete with three blades, down rod, accessories 230V, 1400mm sweep, with minimum air delivery 210 CFM and service value 6.00 BEE, five star rated with squirrel cage induction motor including ceiling cable with twin twisted of suitable length from ceiling rose to fan connector complete all as specified and directed.
S&F BEE 5 star rated exhaust fan AC metallic body single phase 230/ 240 V of size 300 mm sweep with louver and all mounting accessories, including making exhaust fan hole for exhaust fan of size 300 mm sweep on the wall of toilet and suitable length of twin twisted flexible copper wire of size 40/0.0076 Sqmm from ceiling rose to fan connector and all connecting accessories complete suitable for 230 AC, 50 Hz complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth GI wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/ loose soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed. (Note: If the desired resistance is not find, earthing shall be done by the contractor at no extra cost to Govt.)
T.P.SUNIL KUMAR (BID ID -3121573)
lancor builders (BID ID -3119407)
DJ GROUP (BID ID -3130159)
JEETH CONSTRUCTION (BID ID -3127996)
EURO ENTERPRISES (BID ID -3120874)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .