Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC D SURESH L1 ACCEPTED and work awarded to L1 |
| 2 | L2₹1.0 Cr+₹1.1 L (1.04%)Rejected-AOC | ₹1.0 Cr+₹1.1 L (1.04%) | L2 | Rejected-AOC L2 Rejected |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid |
| Sl No | Description | Qty | Unit | DSK ELECTRIC POWER L2 | D SURESH L1 |
|---|---|---|---|---|---|
| 1.00HT | |||||
| 1.00 | OD120667/2023-2024:Supply, conveyance, installation, testing and commissioning of 315 KVA Indoor Type Unitized Substation comprising of H.T. panel trunked with cast resin Transformer with 630A VCB on H.T. side and bottom / top entry cable box as per technical details furnished below. H.T. Portion H.T. Portion consists of 1 No 11K.V, 630A, 350M.V. A VCB with 2O/C relay with high set elements one E/F relay with DC trip with earth inter lock with main switch and mechanical ON/OFF indication, with shunt trip coil for the remote operation of the VCB. Transformer Portion consists of 315 KVA, 11 K.V, 50 Hz, Delta/Star (Dyn-11) connected cast resin insulated copper wound transformer, Ratio 11KV/433, 3 Phase AN cooled. The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish. Class 'F' insulation level shall be maintained. The maximum total loss of the transformer shall meet latest ECBC standards. OFF load tap changing facility shall be incorporated so as to achieve tap position from +5% to -10% in steps of 2.5% changeable by tap links. Temperature scanner with trip annunciator is to be provided. The transformer shall confirm to IS 2026: Part 11 2021/ IEC 60076-11:2018 Dry type Transformer. The transformer shall be subjected to all routine tests as per the relevant IS/ IEC standards and shall have all other standard fittings as per IS: 2026. TOD Metering Facilities consists of 3nos (rating suggested by K.S.E.B) 15VA, 0.2S Class Accuracy Cast resin C.T. 1No 3Phase 3Limb 11KV/110V, 10VA, 0.2 Class accuracy Cast resin P.T. with protective fuses. Provision for fixing TOD meter & test terminal block, (TOD meter and CT, PT unit compartment shall be so fabricated. So as to enable the K.S.E.B authorities to seal it). and including arranging testing and installation of the same with K.S.E.B. Testing Division. LT Portion consists of 1No 4Pole 630A 50KA microprocessor base MCCB inbuilt earth fault with setting range 50-100% with shunt release and rotary handle including NCT and MC12 relay. All inter connection from HT VCB switch to transformer and to LT breaker shall be given using Copper bus bars and support insulators. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side including LT Cable Box. Phase barriers and shrouding as per rules has to be given. The enclosure shall comply to IP 23 standards made of 2 mm CRCA sheet and shall have provisions with Epoxy powder coating the assembly after subjecting to 7 tank processes. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation and efficient Cooling, required including Danger boards, signage, lettering etc. required as per standards. The USS shall be installed at site as per the directions of Engineer in charge. | 1 | each | 12,50,000 ₹12,50,000 Lowest | 12,50,000 ₹12,50,000 Lowest |
| 1.00 | OD133357/2025-2026:Supply, conveyance, Installation, testing and commissioning of 11 kV 630A 3 pole VCB add on breaker, SF6 insulated, outdoor type motor operated, extensible one way, with jointing box suitable to couple with existing RMU. Add on shall be with terminal protectors protection relays with all materials complete conforming to relevant IS/ IEC standards and as per KSEB specifications as required. | 1 | each | 5,90,000 ₹5,90,000 | 4,50,000 ₹4,50,000 Lowest |
| 1.00 | OD93799/2023-2024:MANUAL CALL POINT:- Supply Installation, Testing and Commissioning of Manual Call Points of break glass type with hammer and chain as required | 1 | each | 3,000 ₹3,000 | 825 ₹825 Lowest |
| 1.00 | OD180623/2025-2026:Supply and fixing water proof emergency stop Rotary Self-locking Push-button Switch with IP65 protection and giving connections required. | 1 | each | 3,000 ₹3,000 | 780 ₹780 Lowest |
| 1.00 | OD180433/2025-2026:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 2.5 sq mm with factory made clamp | 60 | metre | 260 ₹15,600 | 230 ₹13,800 Lowest |
| 1.01 | OD93797/2023-2024:Supply and Laying and fixing of one number 11kv 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments on wall surface as required. | 30 | metre | 1,900 ₹57,000 Lowest | 2,300 ₹69,000 |
| 1.01 | OD133698/2025-2026:Supply and laying of one number 11 kv 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments in the existing RCC/ HUME/ METAL pipe as required. | 320 | metre | 1,800 ₹5,76,000 Lowest | 2,200 ₹7,04,000 |
| 1.01 | 10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm | 1 | each | 11,000 ₹11,000 Lowest | 17,232 ₹17,232 |
| 1.01 | 10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete
with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor
cable of 11 KV grade as required :300 sq. mm | 1 | each | 11,000 ₹11,000 Lowest | 24,175 ₹24,175 |
Tender Value
₹1.1 Cr
EMD Value
₹50,000
Closing Date
29 Oct 2025, 6:00 pmClosed
Chief Electrical Engineer
Office of the Chief Electrical Engineer PWD Electrical wing Public Office Thiruvananthapuram
DEPOSIT Standardizing the electrical distribution system and availing HT supply at SAP Camp Peroorkada Tvpm Providing 11KV Supply HT Electrical Work
2025_PWD_812617_1
PWD/BLDG/TR/14054/2023
Open Tender
Electrical Works
Item Rate
300 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹6,508
₹50,000
Yes
24 Jan 2026
21 Oct 2025
31 Oct 2025
21 Oct 2025
29 Oct 2025
21 Oct 2025
21 Oct 2025 - 29 Oct 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1358114.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
SBD.pdf
Tender Documents • 3.01 MB
MOM.pdf
Tender Documents • 0.42 MB
BOQ_1358114.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .