Loading…
Loading…
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
2 Jul 2026, 6:00 pm4d left
Similar tender results from the same govt authority in the past 3 years.
GE(AF) Bareilly
GE(AF) Bareilly (UP)-243002
COMPREHENSIVE MAINTENANCE AND SERVICING OF COOLING APPLIANCES ALONG WITH CONNECTED ITEMS AT AF STN BAREILLY UNDER GE (AF) BAREILLY
2026_MES_771545_1
GE(AF)/BLY/T-05 OF 2026-27
Open Tender
Electrical and Maintenance Works
180 days
Bareilly
Class-D Cat-c(i)
8 documents required · 8 mandatory
₹500
GE(AF) Bareilly
₹56,000
Yes
11 Jun 2026
11 Jun 2026
4 Jul 2026
11 Jun 2026
2 Jul 2026
26 Jun 2026
Repair/ maintenance of cooling appliances like Window/ Split type Air Conditioners, Water Coolers, Refrigerators, Desert coolers, Deep freezers, Dehumidifiers and Flame Proof Air Conditioners etc installed in various buildings of AF Station Bareilly including minor parts such as nut bolts, grease, washer, leakage testing and rectification of leakage by brazing/ soldering/ welding etc by replacing worn-out spares, charging of refrigerant gas etc. including necessary T&Ps and consumables required for cleaning, welding / brazing works etc complete by engaging adequate skilled refrigerator mechanics & helpers on all days during contract period complete all as specified. NOTE : (i) Repalcement of spares and refrigerant gas shall be measured and paid separately as 'Supply only' and the fixing/ charging element is included in the quoted rate. (ii) Rewinding of motors, painting etc shall be measured & paid separately. (iii) All type of T&Ps / Ref mech tool kit related to AC such as Nitrogen/ Leakage /copper brazing/ Alum Brazzing etc will be provided on first day by the contractor and after completion of contract, it will be returned to contractor. (iv) The complaint of above appliances must be rectified / completed within two hours of raising of complaint failing which a penalty of Rs. 500 per complaint shall be levied from the contractor's dues. (v) All the spare items will be of exisiting make and model of AC / Refrigerator / FLP AC / Desert Cooler.
Supply and filling of Refrigerant gas R22 & Refrigerant R134 or any other refrigerant in sealed cylinders.
Servicing of Air Conditioners any type and size such as Window / Split / Tower / Flame Proof AC) including washing out all filters after cover with Jacket and washing with pressure pump to the Indoor unit and Out door unit satisfactory level all as specified.
Servicing of Desert Cooler any type and size including washing out all four side grass filters and washing with pressure pump upto satisfactory level all as specified.
Supply and filling of Refrigerant gas Mafron-32 & Refrigerant R410 or any other refrigerant in sealed cylinders.
Supply only in replacement of Reciprocating type Compressor (sealed unit) suitable for 1.50 Ton capacity window type air conditioner with and including its allied accessories, filling of refrigerant gas all as specified and directed by Engineer-in-Charge. [Make: Tecumseh/Voltas/ Copeland/ Carrier/Blue Star/ Hitachi].
Supply only in replacement of rotary type compressor (sealed unit) suitable for 1.50 Ton capacity window type Air Conditioner with and including its allied accessories, filling of refrigerant gas all as specified and as directed. [Make: Tecumseh / Voltas / Copeland / Carrier / Blue Star / Hitachi].
Supply only in replacement of Reciprocating type Compressor (sealed unit) suitable for 2.0 Ton capacity Split type air conditioner with and including its allied accessories, filling of refrigerant gas all as specified and directed by Engineer-in-Charge. [Make: Tecumseh/Voltas/ Copeland/ Carrier/Blue Star/ Hitachi].
Supply only in replacement of rotary type compressor (sealed unit) suitable for 2.0 Ton capacity Split type Air Conditioner with and including its allied accessories, filling of refrigerant gas all as specified and as directed. [Make: Tecumseh / Voltas / Copeland / Carrier / Blue Star / Hitachi].
Supply only in replacement of Rotary inverter type (DC inverter type) compressor (sealed unit) suitable for 1.50 Ton capacity split type Air Conditioner with and including its allied accessories, refrigerant gas complete all as specified and directed by Engineer-in-Charge. [Make: Tecumseh/Voltas/ Copeland/ Carrier/Blue Star/ Hitachi].
Supply only in replacement of Rotary inverter type (DC inverter type) compressor (sealed unit) suitable for 2.0 Ton capacity split type Air Conditioner with and including its allied accessories, refrigerant gas complete all as specified and directed by Engineer-in-Charge. [Make: Tecumseh/Voltas/ Copeland/ Carrier/Blue Star/ Hitachi].
Supply only in replacement of Rotary inverter type compressor (sealed unit) suitable for 2.0 Ton capacity Flame Proof split type air conditioner with and including its allied accessories, refrigerant gas complete all as per existing Make and model of Sudhir / Shyam / Pluto.
M&L for repair and maintenance of electronic PCB card including repair to relay, driver, transformer diodes, BDR, IC, resistance etc. suitable for 1.5/ 2.0 Ton capacity Air Conditioner of any type and any make complete all as specified and as directed.
M&L for repair and maintenance of electronic PCB card with sensors complete suitable for 1.5 / 2.0 Ton capacity split type AC of any make as per site requirement complete all as specified and as directed.
Opening and separating of split air conditioner of capacity 1.5 Ton of any make Refrigeration and removing of burntout unserviceable air conditioner indoor Unit and S&F new indoor unit of same capcity as per existing make and model including all internal parts complete all as specified. [Make: Voltas / Carrier / Blue Star / LG / Hitachi / Tecumseh / Copeland].
M&L for shifting of any type and size Air Conditioner (Window / Split AC) after taking out the existing electric and indoor / outdoor connections and refixing the same unit at another location without damaging any parts after replacement of damaged copper tubing three mtr long as per existing sizes all as specified.
M&L for repair and maintenance of electronic PCB card of window type AC 1.5 / 2.0 TR capacity including replacement of relay, driver, transformer diodes, BDR, IC, resistance etc complete all as specified.
S&F in replacement of inverter type PCB circuit plate with sensors of indoor PCB cards suitable for outdoor unit of split type AC's 1.5 TR capacity complete all as specified. [Make: Blue Star, Voltas, Carrier, Panasonic]
S&F in replacement of inverter type PCB circuit plate with sensors suitable for indoor unit of split type AC's of 2.0 TR capacity complete all as specified. [Make: Blue Star, Voltas, Carrier, LG]
supply only in replacement of swing motor suitable for indoor unit of inverter type split type ACs of 1.5 / 2.0 Ton capacity complete all as specified.
Supply only in replacment of 50+6 MFD capacity running capacitor suitable for split type Air Conditioner all as specified. [Make: Epcos / Usha / Havells].
Supply only in replacment of 45 MFD capacity running capacitor suitable for split type Air Conditioner complete all as specified. [Make: Epcos/ Usha/ Havells].
Supply only in replacment of capacitor 10 MFD, 230 volts, 50Hz complete all as specified. [Make: Epcos/ Havells/ Usha].
Supply only in replacment of 6 MFD capacity running capacitor suitable for split type Air Conditioner complete all as specified. [Make: Epcos/ Usha/ Havells].
Supply only in replacment of combine PCB card suitable for window type Air Conditioner of any capacity complete all as specified. [Make: LG/ Usha/ Sri Ram/ Blue Star/ Voltas].
Supply only in replacement of copper pipe of 1 run of 1/4" & 1 run of 1/2" covered with heat/ cold resistant nitrile rubber/ foam type insulation in required length complete all as specified and as directed. [Make: MetTube Malaysia/ Totaline].
Supply only in replacement of copper pipe of 1 run of 1/4" & 1 run of ¾" covered with heat/ cold resistant nitrile rubber/ foam type insulation in required length complete all as specified. [Make: MetTube Malaysia/ Totaline].
Supply only in replacement of cooling coil of best quality suitable for indoor / outdoor unit of split ACs any capacity 1.5 / 2 TR complete all as specified.
Supply only in replacement of fan motor of split type ACs 1.5/ 2.0 Ton capacity 220 Volts, 50 Hz with connected items all as specified suitable for existing make.
Supply only in replacement of fan blade set suitable for outdoor unit of Split type AC of any capacity complete all as specified and as directed.
Supply only in replacement of blower along with fins suitable for indoor unit of Split type AC of any capacity and any make complete all as specified and as directed.
Supply only in replacement of copper pipe of 1 run of ⅜" & 1 run of ⅝" covered with heat/ cold resistant nitrile rubber / foam type insulation in required length complete all as specified and as directed. [Make: MetTube Malaysia/ Totaline].
Supply only in replacement of hexagonal flare nut made of brass complete all as specified and as directed.
Supply only in replacement of dead plug made of brass of size ⅝", ⅜", ¼" or ½" as per site requirement suitable for outdoor unit of split type ACs complete all as specified and as directed.
Supply only in replacement of suction valve made of brass of size ⅝" suitable for outdoor unit of split type ACs complete all as specified and as directed.
Supply only in replacement of suction valve made of brass of size ½" suitable for outdoor unit of split type ACs complete all as specified and as directed.
Supply only in replacement ofdischarge valve made of brass of size ⅜" suitable for outdoor unit of split type ACs complete all as specified and as directed.
Supply only in replacement of discharge valve made of brass of size ¼" suitable for outdoor unit of split type ACs complete all as specified and as directed.
Supply only in replacement of air filter pads of best quality for split AC any type and capacity complete all as specified and as directed.
Supply only in replacement of un-plasticized PVC pipe of 25 mm dia having suitable pressure rating, suitable for water drain of split type ACs, fixed to walls, ceilings or in floors and the like including chase cutting on wall and making good the same as per existing complete all as specified and as directed. [Make: FINOLEX / JINDAL / ASIAN / AKG]
Supply only in replacement of MCB single pole and neutral sheet steel enclosure with a two pin and earth plug and socket of metal clad with and including one MCB single pole 20 Amp capacity, 240 volts complete all as specified and as directed.
Supply only in replacement of MCB single pole and neutral sheet steel enclosure with a two pin and earth plug and socket of metal clad with and including one MCB single pole 25 Amp capacity, 240 volts complete all as specified and as directed.
Supply only in replacement of wall or floor mounting type MS powder coated stand suitable for outdoor unit of split AC of any capacity as per site requirement complete all as specified and as directed.
Supply only in replacement of fan motor, single phase, 230 volts, 1350 RPM suitable for outdoor/ indoor unit of 1.5 Ton capacity Flame Proof split type Air Conditioner complete all as specified and as directed.
S&F in repair three core connection lead comprising two single core PVC insulated and sheathed copper conductor cable of size 2.50 Sqmm and one run of earth wire of size 2.50 Sqmm complete all as specified.
Supply only in replacement of blower fan motor suitable for 1.5 / 2.0 TR AC all as specified and directed.
DESERT COOLER Supply only in replacement of spare parts such as motor kit complete with one set of lugs for mounting body of desert cooler any capacity. Make- Khaitan / orient / Crompton
All as per Item No. 47.00 here-in-before but Water booster pump as per existing make and model.
All as per Item No. 47.00 here-in-before but Front grill of mild steel, size 18” to 21” as per site requirement.
All as per Item No. 47.00 here-in-before but Fan blade as per existing make and model.
All as per Item No. 47.00 here-in-before but PVC distributor heavy duty 15 mm size duly fixed with nut-bolts and washers.
All as per Item No. 47.00 here-in-beforebut PVC pipe of 15 mm dia heavy duty.
All as per Item No. 47.00 here-in-before but Running capacitor of 4 MFD capacity. Make- Epcos / Usha / Sharda.
All as per Item No. 47.00 here-in-before but Grass filter pad (set of three) as per sample.
All as per Item No. 47.00 here-in-before but fan blade with motor all as specified.
Supply only in replacement of plug top 3 pin 5 Ampere, 230 Volts, AC suitable for all type of cooling appliances as per requirement complete all as specified and directed.
Supply only in replacement of switch-socket combination, 2-in-1, 3 Pin each for 5 and 15 Ampere, flush type, universal 230 Volts, AC complete all as specified and directed.
Supply only in replacement of component or spare part such as fan motor suitable for desert cooler any capacity all as specified.
Supply only in replacement of stand for desert cooler as per existing any make and model.
Supply only in replacement of 450 mm long 15 mm dia PVC connection with PTMT connectors for desert cooler as per existing any make and model.
Supply only in replacement of PTMT float valve 15mm size. desert cooler as per existing any make and model.
Supply only in replacement of 60 to 80 MFD capacity starting capacitor all as specified. [Make: Epcos/ Usha/ Havells].
Supply only in replacement of 10 MFD capacity starting capacitor all as specified and as directed. [Make: Epcos/ Usha/ Havells]
Supply only in replacement of overload relay all as specified.
WATER COOLERS Supply only in replacement of water tray as per existing size and model.
Supply only in replacement of Overload protector relay for water cooler.
Supply only in replacement of top cover of water cooler as per existing make and model
Supply only in replacement of Compressor suitable for existing make and model of capacity 40 / 80 Ltr Refrigerator.
Supply only in replacement of Compressor suitable for existing make and model of capacity 60 / 120 Ltr Refrigerator.
Supply only in replacement of MCB Single pole, 230 Volts, 20 to 32 Amp, 10 KA all as specified.
REFRIGERATOR / DEEP FREEZER Repair to top door / cover of deep freezer all as specified.
Supply only in replacement of Overload protector relay.
Supply only in replacement of Plug Top with 3 core copper cable lead.
Supply only in replacement of Magnetic door gasket.
Repair to Freezer door complete all as specified.
Supply only in replacement of Vegetable tray.
Supply only in replacement of Compressor suitable for existing make and model of 175 to 235 Ltr capacity Refrigerator.
Supply only in replacement of Compressor suitable for existing make and model of 320 to 500 Ltr capacity Deep Freezer.
Supply only in replacement of MCB Single pole, 230 Volts, 6 to16 Amp, 10 KA all as specified.
S&F for wiring for circuit / submain wiring along with earth wire of size 2 X 4 Sqmm + 1 X 4 Sqmm of FRLS / HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. Note : cutting chasing and repairing of wall surface with existing finishes will be included in the quoted rate of item.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.