Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹10.8 L+₹57,685 (5.62%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹11.2 L+₹91,170 (8.88%)Rejected-Finance MAGHAM RAMAPURAM LANE MUKKOLA P O TRIVANDRUM 695 044 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695044 | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical DD Not submitted. NO remarks in WLR QE Sep 23 of CE Navy Vishakahapattanam |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
3 Feb 2024, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
CLEANING OF SERVICE TANKS AND REPAIR TO FLOAT VALVES IN OFFR/ JCO/ OR ACCN AND OTM ACCN UNDER GE (ARMY) TRIVANDRUM
2024_MES_636044_1
8152/E8
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹20,000
Yes
5 Mar 2024
6 Jan 2024
10 Feb 2024
6 Jan 2024
3 Feb 2024
20 Jan 2024
6 Jan 2024 - 13 Jan 2024
Amount
Disconnecting the existing water tanks of capacity 500 ltrs, setting aside (or lowering if required), dewatering, for repairs, cleaning, sterilization and removing the dirt, sediments, scale, algae formation from inside of tank using cleaning materials such as bleaching powder as required along with scrubbing the inner walls and floor of tank by scrubber and writing the date of cleaning with white synthetic enamel paint over black back ground and hoisting if required reconnecting and re-fixing in position complete all as specified and directed. Note: The rate quoted shall be deemed to be included for carrying out work on roof top at any height. Necessary safety measures/ precautions as per norms for work men shall be taken to avoid accident or such incident
All as per Sl No. 1.00 here-in-before, but water tanks of capacity 1000 ltrs complete all as specified and directed.
All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 1000 ltrs and not exceeding 2000 ltrs complete all as specified and directed.
All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 2000 ltrs and not exceeding 5000 ltrs complete all as specified and directed.
S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for 20 mm bore dia of iron/ PVC pipe (Minimum weight 210gms) complete all as specified and directed.
All as per Sl No. 5.00 here-in-before, but 25mm bore dia (Minimum weight 455gms) complete all as specified and directed.
S&F in repairs ball brass valves, high pressure, with polythene float and flynut complete, screwed for 20 mm bore dia iron pipe or brass ferrule complete all as specified and directed.
All as per Sl No. 7.00 here-in-before, but 25 mm bore dia complete all as specified and directed.
All as per Sl No. 7.00 here-in-before, but 40 mm bore dia complete all as specified and directed.
S&F 40 mm bore dia unplasticised PVC pipes as per ASTM-D-1785 sch 40 plastic pipe with pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe including taking up or down old unserviceable steel tubing/ PVC pipes and connections, complete all as specified and directed.
All as per Sl No. 10.00 here-in-before, but 25mm bore dia complete all as specified and directed.
All as per Sl No. 10.00 here-in-before, but 20mm bore dia complete all as specified and directed.
All as per Sl No. 10.00 here-in-before, but 15mm bore dia complete all as specified and directed.
S&F in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends, conform to IS 778 for 40 mm bore dia iron pipe complete all as specified and directed.
All as per Sl No. 14.00 here-in-before, but 25mm bore dia complete all as specified and directed.
All as per Sl No. 14.00 here-in-before, but 20mm bore dia complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sq.m on plan and not exceeding 1.5 mtr in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in any type of soil obtained from excavation complete all as specified and directed.
Removing excavated material/ surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 metre above starting point complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of existing unserviceable water tank and connecting inlet and outlet pipe lines complete all as specified and directed.
All as per Sl No. 20.00 here-in-before, but 1000 ltrs capacity complete all as specified and directed.
S&F in repairs PVC water tank cover suitable for 500 ltrs/ 1000 ltrs capacity complete with fixing accessories complete all as specified and directed.
Collecting drinking water sample in sterilized bottle from source (Pump Houses) for testing the sample at Govt. Analysis Lab, Kerala water Authority, Kerala Government as per the Government norms and submitting the Lab Test Report in the name of Garrison Engineer (A) Trivandrum quarterly during the period of contract as directed by Eng-in Charge complete all as specified and directed.
SHILPA ENGINEERS AND CONTRACTORS
B.LAMBODHARAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .