| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81,255Admitted-Fee/PreQual/Technical/Finance | ₹81,255 | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹93,369+₹12,114 (14.9%)Admitted-Fee/PreQual/Technical/Finance | ₹93,369+₹12,114 (14.9%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | ARUN.C.S L2 | RATHEESH R L1 |
|---|---|---|---|---|---|
| 1.00Electrification of lift | |||||
| 1.00 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) | 1 | each | 2,900 ₹2,900 | 2,897 ₹2,897 Lowest |
| 1.00 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | 6,700 ₹6,700 | 6,605 ₹6,605 Lowest |
| 1.00 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 12 | each | 350 ₹4,200 | 294 ₹3,528 Lowest |
| 1.00 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | 2 | each | 850 ₹1,700 | 755 ₹1,510 Lowest |
| 1.00 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | 1 | each | 1,250 ₹1,250 | 1,159 ₹1,159 Lowest |
| 1.01 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 6 | each | 20 ₹120 | 14 ₹84 Lowest |
| 1.01 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 600 ₹600 | 500 ₹500 Lowest |
| 1.01 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 amps | 1 | each | 2,400 ₹2,400 | 2,334 ₹2,334 Lowest |
| 1.01 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
40 amps | 1 | each | 3,750 ₹3,750 | 3,670 ₹3,670 Lowest |
Tender Value
₹81,349
EMD Value
₹2,034
Closing Date
14 Aug 2026, 11:00 amClosed
Assistant Engineer
Ottappalam block panchayath
GENERAL Annual plan 2025 26 Completion of Vanitha Training Centre Electrification of Lift in Ottappalam block panchayath
2026_LSGD_863869_1
AE/LSGD/Ottapalam/2026/2phase
Open Tender
Electrical Works
Item Rate
330 days
Ottappalam
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
₹2,034
19 Aug 2026
4 Aug 2026
15 Aug 2026
4 Aug 2026
14 Aug 2026
4 Aug 2026
4 Aug 2026 - 8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrification of lift | |||||
| 1.001 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) | - | each | - | - |
| 1.002 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | - | each | - | - |
| 1.003 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | - | each | - | - |
| 1.004 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | - | each | - | - |
| 1.005 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole | - | each | - | - |
| 1.006 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | - | each | - | - |
| 1.007 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | - | each | - | - |
| 1.008 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 amps | - | each | - | - |
| 1.009 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415
volts, residual current circuit breaker (RCCB), having a sensitivity current 30
milli Amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
40 amps | - | each | - | - |
stage.html
html • 0.02 MB
finance_1461466.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
viewnit.pdf
Tender Documents • 0.03 MB
viewsbd.pdf
Tender Documents • 1.64 MB
BOQ_1461466.xls
BOQ • 0.34 MB
TONED.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .