| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹12.1 L+₹33,184.40 (2.83%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹12.7 L+₹95,388.70 (8.13%)Rejected-Finance VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹12.8 L+₹1.1 L (9.38%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹26,700
Closing Date
15 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
PROVN OF CERTAIN SANCTIONED MINOR, REVENUE AND LBW WORKS IN TECH AREA AND DOMESTIC AREA UNDER AGE B/R-I AT AF STN PHALODI
2020_MES_391072_2
8309A/E8
Open Tender
Civil Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category a(i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹26,700
Yes
30 Dec 2020
20 Nov 2020
17 Dec 2020
20 Nov 2020
15 Dec 2020
3 Dec 2020
20 Nov 2020 - 26 Nov 2020
60 days
Amount
Bldg Works :- Surface dressing n.exc 15 cm deep and getting out in soft/ loose soil complete all as specified and directed. Note :- Watering and removing surplus soil to a distance n exc 50m and making good surface deemed to be included in quoted rate.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/loose soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for reinforced cement concrete Design Mix M-25 as in foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in columns, pillars piers, posts & struts etc complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in Chajjas complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to sides of pillars (square, rectangular or polygonal), posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to chullah hoods, chajjas, troughs and similar items including edges for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
M & L for precast cement concrete 1:5:8 using crushed stone aggregate block masonry with solid blocks exc 10cm in width and setting in cement and sand mortar 1:6 complete all as specified and directed.
M & L for plastering 5mm thick on concrete surface of ceiling in CM 1:3, finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick on stone masonry surfaces or on other than fair faces of brick/PCC block masonry in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work, block masonary or concrete surfaces of walls, mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing compound shall be measured and paid separately under respective item of BOQ.
Supply only integral water proofing compound ISI marked as approved complete all as specified and directed.
M & L for anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L for anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L for anti-termite treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floors, finished the surfaces even and fair complete all as specified and directed.
M & L for 20-25mm thick machine cut Kota stone slab flooring of size 600mm x 600mm, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab over and including 20 mm thick screed bed in CM 1:4 & including rubbing and mirror polishing complete all as specified and directed.
M & L for 20-25mm thick machine cut Kota stone slab as in risers of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in CM 1:3 and jointed with grey cement slurry & mixed with pigment to match the shade of the slab & including rubbing and mirror polishing complete all as specified and directed.
M & L for preparing newly plastered ceiling surfaces and applying two coats of oil bound distemper (OBD) complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of oil bound distemper (OBD) over and including one coat of primer complete all as specified and directed.
M & L for prepariton newly plastered surfaces of wall and applying two coats of acrylic exterior emulsion paint over & including a coat of primer for acrylic exterior emulsion in camouflage pattern complate all as specified and directed.
M & L for 40mm thick cement concrete 1:2:4 Type B-0 (12.5 mm graded aggregate) as in Damp proof course to horizontal or vertical surfaces & including necessary formwork complete all as specified and directed.
BLANK
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydrostop water proofing memdrane manufactured by M/S TIKIDAN as approved by GE, black finish reinforced with non-woven polyester matt (weighing not less than 150 gm/Sqm), with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing with a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, over and including screed bed or bedding layer of mortar, 10 mm thick, in cement mortar 1:4, for laying floor finishes complete all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied @1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
S & F for 1.25mm thick Steel rolling shutters, without ball bearing & incluidng top cover, anchrong rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type complete all as specified and directed.
S & F for ball bearing for rolling shutters of approved make complete all as specified and directed.
M & L for safety lever locks mild steel with 4 leavers for rolling shutters of approved make complete all as specified and directed.
M & L for PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M & L for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L for soft/loose earth filling under floors and including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick each and consolidation complete all as specified and directed. Note:- Earth obtained from item No. 02 (here-in-before) shall be used.
S & F for rolled mild steel as in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering. Door, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing using FE-410-W (Gde- E-250) complete all as specified and directed.
S & F for rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachement using FE-410-W (Gde- E-250) complete all as specified and directed.
M & L for prepration of new steel surface and apply two coats of heat resistant paint on surfaces of any description steel, iron,, etc,. exceeding 10 cm in width or girth with and including one coat of primer complete all as specified and directed.
Dismantling of cement concrete of any description and in any position not other wise specifically provided for including floor tiles mechanically complete all as specified and directed.
S & F of vitreous china wash basin, white, flat back, size 550 x 400 mm & including brackets, bedded in red lead cement and other fixing material & including cutting for and pinning in ends of bracket or erecting stand and waste fittings, brass, chroumium plated with long screwed shanks and fly-nuts, flange etc., complete all as specified and directed.
S & F for 15mm bore, pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, ISI marked, complete all as specified and directed.
S & F of 15 mm bore dia, stop valve, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union, ISI marked, complete all as specified and directed.
S & F of PVC connection 15mm dia 450mm long with PTMT check nut and washer etc, ISI marked, complete all as specified and directed.
S & F of PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32 mm dia complate all as specified and directed.
S & F of steel water tubing 15mm bore dia, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor and including testing complete all as specified and directed.
S & F of steel water tubing 20mm bore dia, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor and including testing complete all as specified and directed.
S & F of Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
S & F of portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 fixing holdfast and bracket complete all as specified and directed.
Cutting holes exc half brick but n.exc one brick in PCC block masonary walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including a coat of red oxide primer complete all as specified and directed.
E & M Works:- M&L for flameproof point wiring for one light point controlled by one switch with 1.5 Sqmm (nominal cross section area) FR-LSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed in stove enamelled steel conduit of 20 mm dia, medium grade, ISI marked, with fittings such as pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls for conduits and for sunken pressed steel fire proof terminal boxes and making good the disturbed surface with all jointing accessories & including provision of pressed steel sunken fire proof terminal boxes 60mm deep, suitable length and 1.2mm thick painted with fire resistant paint and making good disturbed surfaces of wall in CM 1:3 for mounting modular fire proof switches, sockets, etc covered with & including 3mm thick MS sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated unsheathed multistranded, FR-LSH copper conductor wire as earth continuity to common earth and connecting to earth dolly complete all as specified and directed. Note :- Flame proof switches / sockets etc shall be measured and paid for seprately under appropriate items of BOQ.
S & F flame proof switch, rotary type with termination box in LM6, 16 Amp, single pole ON-OFF, 250 Volt, ISI marked, complete all as specified and directed.
Supply and Fixing LED Flame proof batten suitable for twin T8 tube of 16W , IP 65 protected complete all as specified and directed. Make :- Cat part No EXTN2LT8-16/20 of Crompton or equivalent in Sudhir or Shyam
Supply, fixing and testing exhaust fan 380mm sweep, metal body, single phase and double ball bearing, 230/240 Volts, 50 Hz, 1380 RPM, 1600 Cubic metre per hour minimum air delivery with and including louver shutter, masquito proofing to opening and including provn of holes in 380 to 400mm thick existing PCC block/brick masonary wall (built in cement mortar), grouting of studs in wall in cement mortar (1:3) nuts, washers, making surfaces of hole and edges, including RCC hume pipe, 380mm dia and length 300mm or as per width of existing wall and making good the surfaces even and fair by providing cement plaster in cement and sand mortar (1:3) to match with existing surfaces with existing finishes alonwith all accessories complete all as specified and directed.
Supply and Fixing Flame proof CFL bulk Head fitting for 2 Nos 23/36W Retrofit type lamps complete all as specified and directed.
Supply and fixing flame proof double door sheet metal enclosure made out of CRCA steel sheet concealed surface mounting SPN, 2 way, 415 Volt, with 200 Amp rated bus bar suitable for fixing flame proof MCBs, isolators etc complete all as specified and directed.
S&F flame proof isolator DP 40 amp 'C' curves MCB rupturing capacity 10 KA etc complete all as specified and directed.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mesh for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using 20mm crushed stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion. Note : (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) The cost of 7.5m earth lead /copper strip and GI pipe for protection of earth lead & watering/strip upto 7.5m is included in the quoted rate. (iii) The cost of excavation, earth work, RCC & PCC etc are included in the quoted rate. (iv) On testing after completion, if the earth resistance less than 1 Ohms is not obtained earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained.
M&L for Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 25X4 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 3 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs complete all as specified and directed with earth resistance not more than 1.0 OHMS.Writing of details on the surface of the pit with paint all as directed by Engr-in-Charge. Note- In case earth resistance more than 1.0 ohms, the contractor wiil re earthing at no extra cost . Note : (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) The cost of 7.5m earth lead /copper strip and GI pipe for protection of earth lead & watering/strip upto 7.5m is included in the quoted rate. (iii) The cost of excavation, earth work, RCC & PCC etc are included in the quoted rate. (iv) On testing after completion, if the earth resistance less than 1 Ohms is not obtained earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained.
Supply and fix galvanised Iron strip 32mm x 6mm size burried in ground /floor or fixed to wall /pole etc complete including riveting, soldering or brazing of joint etc complete all as specified and as directed.
M&L for Test point terminal block made of Gun Metal or Phosphorous bronze size 75 x 75 x 25 mm drilled & screwed incl 3 Nos, 8mm dia, 25mm long Hexagonal head Screw complete all as specified and directed.
Supply and fix of Aluminium strip of size 25 X 3.15 mm thickness with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supplying and laying/fixing GI tubing light grade 40 mm bore dia for encasing cables/strip for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as mounting bracket bend to shape with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works incl PCC 1: 2 : 4 on roof with necessary fixing arrangements the Air terminations Single Pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
Supply and fix Air termination , single pointed copper rod 12 mm dia and 300 mm long complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning of cross sectional area 2 core 16 Sqmm LT under ground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall complete all as specified and directed Note :- Exacavation and earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid seprately under respective items of the BOQ.
M & L for dry tibba sand free from clay for cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover to cable all as per standard schedule rates Part-I (2009) complete all as specified and directed. Note:- Thickness after punning shall be considered for payment.
Supplying and laying of un-reinforced precast cement concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Materia and labour for boring / augaing of holes under road/ pavement/ hard standing or any other situation by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4mpa working pressure complete all as specified & directed.
Supply, laying and fixing GI pipe 50 mm bore light grade for protection of cable as in trenches/along pole / wall / laid under the road / laid under the floor etc., including clamps complete all as specified and directed. Note :- Excavation & earth work shall be measured & paid for separately under respective item of this BOQ.
S & F of flame proof LED 2X18Watt, 4' long (1200mm) complete all as specified and directed.
S & F of flame proof double door sheet metal enclosure made out of CRCA steel concealed surface mounting SPN 4 way, 415 Volt ith 200 Amp rated bus bar suitable for fixing flame proof MCBs, isolators etc complete all as specified and directed.
S & F of flame proof MCB 6 Amp to 25 Amp SP 'C' series 10KA rupturing capacity complete all as specified and directed.
M & L for flame proof exhaust fan 380mm sweep, metal body, capacity of motor 0.25HP, 1440 RPM, 1120CFM single phase 230 Volts and including louver shutter, masquito proofing to opening and including provn of holes in 380 to 400mm thick existing PCC block/brick masonary wall (built in cement mortar), grouting of studs in wall in cement mortar (1:3) nuts, washers, making surfaces of hole and edges, including RCC hume pipe, 380mm dia and length 300mm or as per width of existing wall and making good the surfaces even and fair by providing cement plaster in cement and sand mortar (1:3) to match with existing surfaces with existing finishes alonwith all accessories complete all as specified and directed.
Supplying, laying, jointing, testing and commisioning of cross sectional area 2 core 10 Sqmm LT under ground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall complete all as specified and directed Note :- Exacavation and earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid seprately under respective items of the BOQ.
M/S BAKSARAM AND COMPANY
M/S SIDHU CONSTRUCTION COMPANY
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .