Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹41.9 L+₹82,216 (2.00%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹42.4 L+₹1.3 L (3.04%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹43.0 L+₹1.9 L (4.67%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹43.2 L+₹2.1 L (5.09%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Jun 2021, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
PROVN OF ADDATION/ALTERATION TO CERTAIN ROOMS OF SOs MESS, SINGLE LIVING MESS, 30 METERS DAMAGED SECURITY WALL WITH BARBED WIRE AND PROVISION OF VALLEY BALL COURT AT ICGS VADINAR UNDER GE I CG PORBANDAR
2021_MES_445128_1
8617
Open Tender
Civil Works
Item Rate
180 days
ICGS VADINAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹80,000
Yes
15 Jul 2021
24 May 2021
14 Jun 2021
24 May 2021
12 Jun 2021
7 Jun 2021
Amount
SCHEDULE 'A'
Surface excavation n.exc. 30cm deep and averaging 30cm deep and getting out in any type of soil.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in soft/disintegrated rock complete all as specified and directed by Engr-in-Charge.
Excavation in trenches in soft/dis-integrated rock n.exc 1.5m wide and n. exc 1.5m depth for laying of pipe line , complete all as specified and as directed by Engineer-in-Charge.
Rough excavation not exc 1.5m deep for approved earth as directed by Engr - in- charge
M&L for moorum / Red bajri filling in floors or pavings laid in layers n.exc 15cm thick, spread, levelled and rammed including watering and consolidation all as directed by Engr-in-Charge.
Removing of excavated soil to a distance n.exe 50m and depositing where directed at a level not exe 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thick Sand filling under floors/ foundation including watering and consolidation complete all as directed by Engr-in-Charge.
Rolling the formation surface using 8 to 10 Ton roller complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n.exc. 0.5 cum, getting out returning filling in and ramming earth or broken rubble mixed with earth around, in l;ayers n.exc. 25 cm in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L Plain Cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Plain Cement Concrete Type D2, 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete foundations, footings,bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter,for rough finished surfaces of flat concrete complete all as specified and directed by Engineer-in-Charge.
Form Work to sides of pillars colums square or rectangular ,for rough finished surfaces of flat concrete complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of flat concrete complete all as specified and directed by Engineer-in-Charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in foundation including raft footing foundation beam plinth beam bases for columns etc basement slab under reamed piles and mass concrete Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in Columns,pillars,piers, posts and struts Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in beams,cantilevers, bressumers and lintels over 1.5 mtr span complete all as specified and directed by Engr-in-charge. Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge
M&L Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. etc complete all as specified and directed by Engr-in-charge.
All as per above item No.19.00 but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders etc complete all as specified and directed by Engr-in-charge.
M&L pre-cast cement concrete block masonary in PCC 1:3:6 type C1 using 20mm graded aggregate with solid block, exceeding 10 cm in width and setting in CM 1:6 complete
S&F Size of grid 605 x 605 mm GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre complete all as specified and as directed by Engr-in-Charge.
M&L Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed by Engr-in-Charge.
Ditto-but to curved surface complete all as specified and as directed by Engr-in-Charge.
Extra over item above for any sunk or curved moulding complete all as specified and as directed by Engr-in-Charge.
M&L for bands, straps, supports or stays for rainwater, fencing posts, ventilating pipes,including bolts, if required , hooks (stay) heavy for large gates, hook and pintle hinges; large hasps and staples, chains, hand made sliding bolts, clamps , hold fast, wall ties, hook for hanging fans, knee piece inserts, two way and three way straps, plates washers and similar small artical conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F of mild steel angles,bars, flats etc as in supports for posts and struts in fencing including cutting tops to shape as directed,drilling holes,notching for wire,etc, flat iron fillets (For securing wire mesh etc.,) including all necessary drilling,bolting or riveting,etc., and similar work conforming to fe 410-0 or Fe 310-0.
S&F Epoxy coated (pre-painted) Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed by Engineer-in-Charge.
M&L rendering 15 mm thick on fair faces of Brick work/PCC block masonry or Concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of new plastered surfaces and applying two coats of exterior weather proof paint (acrylic emulsion paint) over coat of primer complete all as specifed and as directed.
M&L for preparation of ceiling surfaces and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of wall applying two coat OBD over a coat of chalk white primer of approved shade all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed by Engineer-in-Charge.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed by Engineer-in-Charge.
S& F GI Posts incl winch welded to post,GI cap, Pulleys & 15mm eye bolt,set of 02 Nosincluding nylon Volley ball court net & Marking on Volley ball court with approved paint complete all as per IS complete all as specified and directed by Engineer-in-Charge.
S&F wall panelling made up of UPVC foam profile with homogenous fine cellular structure having smooh outer intergral skin having 250mm wide tounge and groove design with 10mm thickness of required shade, the internal batten having 35mm width and 17mm thickness, The batten aligned horizontally along the wall with 50mm gap above the floor and below the ceiling. The internal batten shall be fixed 450mm centre to centre in between junction and corners should be covered with foam beading profiles including providing 17mm thick EPS Sheet as insulation and better rigidity of wall panelling between wall and paneling complete all as specified and as directed by Engr-in-Charge. Make: Accucel or Equivalent
M&L Granules(Grit finish) textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kg per Pack) made of 92% silica particles coated with fade resistant pigment, 100% acrylic polymer bonding agent (5 Kg per pack) with the applied thickness of the coating being between 0.8mm -1.2mm to be applied on curved, smooth level plaster without key, as per manufacture directions, for usages to be applied and approved applicator of the manufacture as per the direction/ supervision of the Engineer-in-charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476:Part 7:1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surfaces complete all as specified. Make:- Bakelite Hylam Limited or equivalent make approved by the GE.
Providing and fixing Aluminum Composite panels in all coloures of approved brand for external / internal wall cladding at all heights and elevations including necessary aluminium composite panel consist of 3mm thermoplastic core of anti oxident LDPE sandwitched between two skin of 0.5 mm thick alloy sheet making a total sheet thickness of 4 mm. The surface shall be finished with PDVF base coating on the top side and service coating on the reverse side shall be with a polymer paint. The system to be fixed to the brick/stone/masonry/RCC walls/framed structure with necessary clamps, bracket and anchor fasteners fixed over and including base frame fabricated with aluminium square pipe of size 25mmx20mm with 1mm thickness in 600mmx600mm size grid including stainless steel screws, nut, bolts, washers, cleats, weather silicone sealent for groove filling, backer rods etc, complete all as per Manufacturer instruction and all as specified and as directed by Engr-in-Charge. All Clamps and brackets shall be hot dip galvanised minimum 80 micron thick and confirmed to IS : 4759 - 1996. The extruded aluminium sections shall be anodised in approved colour with anodic coating minimum 20 microns. (items include cost of aluminium frame, ACP Panels, Cramps, weather sealent, gasket, foam, fixtures, scaffolding, all machineries and any other fastening streps, nuts, bolts, rivets, washers, etc complete). The manufacturer shall also give guarantee/warranty for ACP panels for a period of Five years. Make of ACP:- ALUPEX/ALUDECOR/ALSTRONG.
Demolition of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of RCC of any description in any postion complete all as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified
Dismantling fencing wire mesh, any type
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core
Supply and Lay, 40 mm OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings all as speciifed and directed.
Supply and fix LED Flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed Make : Philips/Wipro/CG
Supply and fix Octagonal hot dip galvanised iron pole, 7m long with base plate, 300 mm long weather proof reinforced door opening with junction box mounting arrangement, inbuilt junction box, 'J' shape, EN8 foundation bolt with nuts template including RCC foundation as per manuacturer's design conforming to IS 1786. The foundation shall extend above surrounding levels by 200mm all as directed by Engineer-in-charge. Make :Surya/ Bajaj /Utkarsh NOTE :The contractor should submit manufacturer's foundation drawing before commencement of foundation work. Excavation/earthwork, removal and returning filling included in the quoted rate.
M&L for MCB Single pole & nutral 215 Volts 32 Amps
M&L Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets and fan regulators complete all as specified and as directed by Engineer-in-Charge. for the following:- Make of cable: Havells/ Finolex/ RR Kable/ KEI (a) One light point /fan point controlled by one switch with cable 1.5 Sqmm
For one 3 pin socket outlet 5 Amps on the same board with other switches with cable of size 1.5 Sqmm nominal area
For one 3 pin socket outlet 5 Amps independent board with cable 1.5 Sqmm nominal area
M&L Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 2.8mm thick bakelite sheet white/coloured top cover for mounting of modular switches, sockets and fan regulators complete all as specified and as directed by Engineer-in-Charge. for the following:- Make of cable: Havells/ Finolex/ RR Kable/ KEI (a) one 3/5 pin 15/16 Amps socket
S&F Modular switch 1 way, 10 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular switch 1 way, 16 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular socket, 6 Amps, 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified and as directed. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular fan regulator, 120 watt, 2 modular (ISI marked) complete all as specified and as directed. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
M&L for sub main wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
Supply and fix sheet metal enclosure for Triple pole and neutral DBs when MCBs to be used 4,way 415 V double door with 200 Amps bus bar. Make:Legrand/Schneider/L&T
S&F MCB SP 5/32 Amps 10 KA rupturing capacity 'C' curve complete all as specified and as directed by Engineer-in-Charge. Make: L&T/ C&S/ Legrand/ Schneider
M&L for MCB Triple pole & nutral 415 Volts 32 Amps 10 KA rupturing capacity 'C' curve complete all as specified and as directed by Engineer-in-Charge. Make: L&T/ C&S/ Legrand/ Schneider
S&F recessed mounted LED luminaire, nominal lumen output 1600 lm, IP 20, pressure die cast aluminium ,operating voltage range 220-240 volts,system efficacy > 60lm/W THD<10%, PF>0.9, complete all as specified and directed by Engr-in-Charge. Make: Philips Cat Part No DN 394B LED16S-6500 PSU WH or equivalent in Wipro
S&F recessed mounted LED luminaire, nominal lumen output 1200 lm, IP 20, pressure die cast aluminium ,operating voltage range 220-240 volts,system efficacy > 60lm/W THD<10%, PF>0.9, complete all as specified and directed by Engr-in-Charge. Make: Philips Cat Part No DN 393B LED12S-6500 PSU WH or equivalent in Wipro
ambika electric co
SURAJ ENTERPRISE
K K Construction Co
JAYESH TRADING CORPORATION
SURESH ELECTRICALS
fakhrie apostrical
JAMNAGAR ELECTRIC AND MACHINERY CO
Nitesh Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .