Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹49.3 L
EMD Value
₹98,500
Closing Date
27 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager RSRDC Ltd. Jaipur
Office of the Project Director RSRDC Ltd. Unit-Electrical, Jodhpur. High Court Campus, Near Shatabdi Circle, Jodhpur
SITC of 6 Passengers Panoramic/Transparent Lift at National Law University, Jodhpur
2025_RSRDC_513910_1
RSRDC NIT 501/2025-26 (Sl-1)
Open Tender
Electrical Works
Percentage
90 days
Jodhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Through RTGS/NEFT/IMPS
₹98,500
18 Nov 2025
18 Nov 2025
28 Nov 2025
18 Nov 2025
27 Nov 2025
19 Nov 2025
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Medium point (up to 6 mtr.)
Long point (up to 10 mtr.)
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
On board
Short point (up to 3 mtr.)
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
LED Street Light fixture with Minimum lumen output 5600 lm
Providing & Fixing of of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
250 mm sweep
Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Minimum lumen output 1000 lm
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Metal door (Three phase) IK-09 and IP-43 with Metal end box
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Single pole MCB (With B/C curve tripping Characteristics)
6 A to 32 A rating
Four pole MCB (With B/C curve tripping Characteristics)
50/63 A rating
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Four pole 100/300 mA sensitivity
63 A rating
Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point me
ntioned (a), (b), [c), (d), (e) below :-
(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
(b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts
© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
(d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.
(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.
(e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
17.2 mm thick and 3 Mtr. Long
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
8 SWG tinned copper Wire
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:
New work (Two or more coats applied @ 3.84 kg/10 sqm).
Supplying , installation , Testing and commissioning of the panoramic/Transparent passenger lift with Transparent / Glass enclosure with MS structure Shaft Type having following main features:
(a)MOTOR : Gearless lift drive comprising of high starting torque lift duty , 3 phase 440 Volts A.C. permanent magnetic synchronous motor inverter-driven (VVVF) of proper rating with high efficiency shall be used. (IP44 / IP54)
( c ) Traction Media: main hoist flat coated steel belt / rope . Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.
(d) Car : MS car frame with inner floor support, welded stiffeners, lifting eyes, provision for glass panels fixings.Toughened laminated glass (e.g., 12 mm toughened + 6 mm PVB + 12 mm toughened if required) or single tempered 10–12 mm depending on design. Fixing with rubber gaskets & stainless steel clamps. Provide silicone sealant and to sustain the impact load cabin plus passengers with safety factor of fire for steel withAnti skid PVC flooring and side panels , Interior glass panels or SS cladding for edges, 1 no. SS handrail (height 900 mm) . Car ceiling shall be steel finish with aesthetic appearances with Suspended ceiling with LED downlights, emergency light, smoke detector provision .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts . COP with buttons, braille, floor display, alarm bell, telephone/intercom provision .LOP per landing, LED display, direction arrow . Floor announcement, LED floor indicator inside & at landings. All car panel buttons and all floor switches must be with braille language as per lift act. Agency shall give provision of CCTV camera in the car complete with connecting cables & accessories (To be connected with existing CCTV system in the Building) .The inspection unit shall be provided at the top of the car.Stainless Steel (Grade SS 304, 1.2 mm thick) with optional full-height clear toughened glass vision panels.(Car frame: MS welded frame with floor support, lifting points, vibration damping pads.)
(f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided.
(g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR.
(h) Audio-Visual Indication : Audio visual indication in the lift car , showing over loading such that doors kept open till excess load is removed.
(i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors.
(j) Buffers :Spring buffers/PU Buffers shall be provided.
(k) Car Fan :ENERGY EFFICIENTCar fan/blower with automatic sleep timer shall be provided.
(l) Voice Annunciator: Voice annunciator with suitable music shall be provided in lift car.
(m) Self diagnostics system for operational and safety parameters shall be provided in control panel .
(n) Mechanical/Electronic over speed governor , door key holes in the floor doors, fireman switch shall be provided .
(o) Glazing:-External glazing: Laminated toughened glass recommended for safety: typical arrangement 12mm T + PVB + 12mm T or tempered 12mm depending on wind loads & balustrade design.Fixing: SS 304 clamps, EPDM gaskets, silicone sealant. Wind load checks required by structural engineer
(p)MRL Hoist shall be mounted on MS structural beams fixed at the top of the shaft structure (as per structural drawing). counter balance to promote smooth and economic operation complete with steel guide rails for the car & counter weight ,Anti-vibration pads provided between motor frame and mounting beams.Provide working platform and maintenance access ladder at hoist level with safety railings Provide by the agency along with all other steel structure works etc as required.
(q) Guide Rails, Rail Brackets & Guide Shoes Precision-ground guide rails (steel), anti-friction guide shoes, brackets, fishplates & alignment checks.
® IoT monitoring: Install vibration/temperature/door-cycle sensors + gateway for predictive maintenance and remote diagnostics (reduces downtime)
(s) The foundation shall be designed to safely support the full dead load, live load, and dynamic loads of the lift and its supporting MS structural frame.Design shall conform to IS 456:2000 (Plain & Reinforced Concrete), IS 800:2007 (Steel Structures), and IS 875 (Part 1 to 5) for loadings.The foundation shall also resist vibration, wind, and seismic forces (if applicable as per IS 1893). Foundation Depth As per soil report (minimum 450 mm below natural ground level) .all Civil foundation work Related to Panormic Lift shall be done by the lif
t erecting agency without any extra cost.
(t) Type of Foundation:-Isolated RCC Footings or Raft Slab depending on soil bearing capacity (SBC).Minimum SBC = 150 kN/m² (verify through site soil report).The base of the MS structural lift frame columns shall be anchored to RCC foundation pedestals with grouted anchor bolts.
(u) Anchor Bolts & Grouting:-Use M24 / M30 foundation bolts, 450–600 mm long (as per design).Material: Grade 8.8 high-tensile galvanized bolts.mbed bolts in foundation with sleeves or templates to ensure precise alignment.After erection, use non-shrink grout (e.g., Fosroc Conbextra GP2 / equivalent) for base plate grouting.Maintain minimum 40 mm grout thickness under base plate
(v) Waterproofing & Drainage:-Apply crystalline waterproofing coating on pit base and side walls.Provide sump pit (300×300×300 mm) with drain line for water removal.Seal all cable/conduit entries with non-shrink sealant to prevent leakage.
(w) Earthing & Electrical Provisions:-Provide two dedicated earth pits for lift structure and electrical system (as per IS 3043).Use 25×3 mm GI strip or 16 mm² Cu wire for earthing connection to MS frame.Embed conduits for power/control cables before concreting the foundation.
(x) MS Structural Shaft Frame (Main support frame for panoramic glazing & guide rails) IS2062 / Fe410 MS sections (columns & horizontal beams), plate welded frame for car guide & glass support. Surface: sandblast, zinc primer + 2 coats epoxy/polyurethane finish. Provide anchor plate for foundation.Supply, fabricate, primer & paint, site welding, bolting, grouting of anchor bolts.MS Structure lift wall with MS square pipe 150mm x150mm having cross section with 75 mm angle, back side glass with 50mm angle frame .all MS Structural Shaft Frame work Related to Panormic Lift shall be done by the lift erecting agency without any extra cost.
(y) Safety:-Safety gear, overspeed governor, safety circuit, door interlocks, emergency alarm, two-way communication (telephone/intercom).Load test at 125% rated load and certify as per local regulations.
( z) Agency has to provide all working drawings and documents to comply latest BIS specifications and make proper liasion services for obtaining all necessary permissions.
(ai) Electric work :- Power supply: 3-phase, 415V, 50Hz (or project supply). Provide dedicated MCB/RCCB, isolator.Lightning protection as needed. All Eletric Work Related to lift Wiring, Electric Point, Distribution Board For lift, RCCB For lift , cable of 3 phase supply for lift shall be done by the lift erecting agency without any extra cost.
(b2) O&M Manuals, As-Built Drawings & Software Handover Operation manual, maintenance schedule, wiring diagrams, IoT access & credentials.
® AMC & statutory permission: Comprehensive AMC of lift for 5 years including obtaining all necessary erection permissions & "License to Work the Lift" from Lift Inspector (if required)
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.31 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BankDetail00.pdf
Tender Documents • 0.17 MB
BOQ_916728.xls
BOQ • 0.38 MB
AgrrementRTPPandetc.pdf
Tender Documents • 2.75 MB
LIFT_Conditions.pdf
Tender Documents • 1.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .