Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC JARATHA CORNER LAKSHAM VEEDU COLONY ROAD | THIRUVARUR | TAMIL NADU | 609403 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹14.1 L+₹20,954.98 (1.51%)Accepted-AOC | L2 | Accepted-AOC HIGH | |
| 3 | L3₹15.0 L+₹1.1 L (7.85%)Accepted-AOC PULINCHOTTIL HOUSE KAYANTIKKARA MUPPATHADAM PO | ERNAKULAM | KERALA | 680667 | L3 | Accepted-AOC HIGH |
| Sl No | Description | Qty | Unit | SHANAVAS T.S L1 | SHAJEER P B L3 | ROSHAN SEBASTIAN L2 |
|---|---|---|---|---|---|---|
| 1.00Roof | ||||||
| 1.00 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | 3,880.17 | kg | 183.8 ₹7,13,174.51 Lowest | 198.16 ₹7,68,893.69 | 186.5 ₹7,23,650.96 |
| 1.00 | OD202283/2025-2026:providing and fixing 200 mm wide square uPVC rain water gutter including all necessary fittings and making all necessary connections complete as per the direction of engineer in charge at site | 59.6 | metre | 474.82 ₹28,299.27 Lowest | 511.53 ₹30,487.19 | 481.44 ₹28,693.82 |
| 1.00 | 12.41.1:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter | 38.4 | metre | 252.88 ₹9,710.59 Lowest | 272.43 ₹10,461.31 | 256.41 ₹9,846.14 |
| 1.00 | 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm) | 32 | metre | 534.98 ₹17,119.36 Lowest | 576.35 ₹18,443.2 | 542.45 ₹17,358.4 |
| 1.00 | OD202345/2025-2026:Providing and fixing precoated galvanised hard colour powder coated trafford sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.<br> | 265.64 | sqm | 510 ₹1,35,478.44 Lowest | 549.46 ₹1,45,960.75 | 517.14 ₹1,37,375.14 |
| 1.01 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 0.16 | cum | 7,510 ₹1,171.56 Lowest | 8,091.55 ₹1,262.28 | 7,615.57 ₹1,188.03 |
| 1.01 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 1.17 | cum | 8,743 ₹10,229.31 Lowest | 9,420.69 ₹11,022.21 | 8,866.53 ₹10,373.84 |
| 1.01 | 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns | 18.72 | sqm | 365 ₹6,832.8 Lowest | 393.88 ₹7,373.43 | 370.71 ₹6,939.69 |
| 1.01 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 0.11 | cum | 9,930 ₹1,072.44 Lowest | 10,698.55 ₹1,155.44 | 10,069.22 ₹1,087.48 |
Tender Value
₹14.7 L
EMD Value
₹36,734
Closing Date
8 Sept 2025, 6:00 pmClosed
The Assistant Engineer, LSGD Section, Cheranelloor
The Assistant Engineer, LSGD Section, Cheranelloor
Annual Plan-PROJECT NO279/2025-26-SC flat construction combined-General Civil Work-CHERANALLOOR GP
2025_LSGD_791544_1
T26/AE/CHR/2025-2026
Open Tender
Civil Works - Roads
Item Rate
cheranelloor
Annual Plan-PROJECT NO279/2025-26-SC
flat construction combined-General Civil
Work-CHERANALLOOR GP
9 documents required · 9 mandatory
₹2,760
Yes
₹36,734
Yes
16 Sept 2025
26 Aug 2025
11 Sept 2025
26 Aug 2025
8 Sept 2025
26 Aug 2025
26 Aug 2025 - 8 Sept 2025
Amount
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
OD202283/2025-2026:providing and fixing 200 mm wide square uPVC rain water gutter including all necessary fittings and making all necessary connections complete as per the direction of engineer in charge at site
12.41.1:Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
OD202345/2025-2026:Providing and fixing precoated galvanised hard colour powder coated trafford sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.<br>
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
OD202716/2025-2026:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications excluding priming coat, preparation of surface, etc. complete. On steel work
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
ROSHAN SEBASTIAN (BID ID -2327662)
SHAJEER P B (BID ID -2327744)
Bidder Name
SHAJEER P B
SHANAVAS T.S
ROSHAN SEBASTIAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1305297.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .