| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance RZ 128 A DHARAMPURA EXTENSION NAJAFGARH NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-Documents physically not submitted in division office |
Tender Value
₹8.8 L
EMD Value
₹17,641
Closing Date
22 Dec 2023, 3:00 pmClosed
EE(E) BCP
MTNL T.E. Building BCP, New Delhi
Testing of existing earthing and providing lightening protection system, maintenance free chemical-earthing and aviation light for 4G Towers under A.E.(E)BCP, MTNL, Delhi
2023_MTNL_785000_1
EE(E)BCP/MTNL/NIT/2023-24/92
Open Tender
Miscellaneous Services
Item Rate
30 days
Delhi
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
Yes
MTNL DELHI
₹17,641
Yes
23 Dec 2023
12 Dec 2023
23 Dec 2023
12 Dec 2023
22 Dec 2023
12 Dec 2023
Amount
TESTING OF EXISTING OLD EARTHING FOR TELECOM TOWERS: Testing of existing earthing with digital earth-meggar kit and submitting the report to the engineer-in-charge. Value of earth-resistance as tested individually for each earthing as well as the combined value after interconnecting earthing through GI earth strip must be less than 1 ohm. Watering the existing earthing (i/c addition of salt, if required) also to be done by the firm for achieving desired earth results wherever existing earthing found dry. (Note: One job implies one earth-pit, irrespective of the number of earth-pits at one site. However, the item shall be measured and paid only in case existing earthing results are satisfactory and existing old earthing need not to be replaced with new earthing).
MAINTENANCE-FREE CHEMICAL EARTHING FOR TELECOM TOWERS: SITC Earthing with COPPER BONDED STEEL EARTH PIPE ELECTRODE 3.0 MTR LONG, 17.2mm diameter having uniform copper bonding of minimum 250micron thickness all around the steel electrode (UL approved & CPRI tested) and having pointed tip bottom and copper coated clamp- at top- having 4 holes for connecting eart-strip & M10 x 35mm SS nut-bolt and spring washers including accessories and providing Heavy-duty of 2000 Kgs load bearing capacity polyplastic/HDPE weatherproof enclosure of suitable size (not less than 250mm deep x 300mm wide) with cover plate having locking arrangement including digging the earth pit of suitable dia. and depth in ground (soft/hard bed) and refilling the same with maintenance-free environmental friendly semi-soluble, non-corrosive, conductivity improving mineral back-fill compound (25kg-30kg) etc. complete as required including testing the earthing results with digital earth-meggar. (Earthing Make: RDSO approved) (Note: Value of earth-resitance as tested individually for each earthing as well as the combined value after interconnecting both earthing through 25mmx5mm GI earth strip must be less than 1 ohm).
Supplying, laying & fixing 25mm x 5mm GI strip on surface/in recess/ underground at 0.50mtr below ground as strip earth electrode, including connection/terminating with GI nut-bolt spring-washer including excavation and refilling etc. complete as required. (Jointing shall be done by overlapping and with 2 sets of GI nut-bolt and spring washer spaced at 50mm, GI strip to be clamped using GI clamps at distance between two clamps not more than 0.5mtr in case of surface GI strip). Note: Pvdg& fixing of PVC insulation sleeve on GI strip wherever required to be carried-out as per site-requirement without any extra charges.
Providing and fixing testing joint made of 25mm x 5mm thick GI strip, 125mm long, with 4 numbers of GI nuts-bolts, check-nuts and spring washers etc. complete as required.
Providing and fixing testing joint FRP Box Size 200 mm X200mm ,including 20x3 mm thick x125 mm long G.I. strip, with 4 nos insulators,. G.I nut .bolts, chuck nuts and spring washers etc. complete as required.
LIGHTENING ARRESTOR FOR TELECOM TOWERS: Providing and fixing of lightning-arrestor made of 25mm dia. hollow tubular copper finial 1500mm long having minimum 1.6mm wall thickness and five number copper spikes at top, 140mmx140mmx6mm thick G.I. base plate including holes, nut-bolts and other fixing arrangements etc. complete as required as per approved drawing. The lightening arrestor shall have threading in the lower 130mm portion of the finial and duly tinned. The Lightening Arrestor shall be fixed to the tower with a Teflon sheet/ Earthing insulator to avoid direct contact with the tower.
LOW INTENSITY LED TYPE TWIN AVIATION OBSTRUCTION LIGHT ON TELECOM TOWERS: SITC of Low Intensity LED type TWIN Aviation Obstruction Light with photo-sensor, having die-cast aluminium housing, Red Polycarbonate dome (or Red coloured LED with white polycarbonate dome) for better illumination, integral driver, IP 65 protection and suitable for operation on 240V, 50Hz single phase AC supply (with wide operating voltage range 100V to 270V AC), inbuilt protection against short-circuit and surge, complete with mounting fixture as per specifications including making connections etc. complete as reqd. . The aviation light fixing/mounting arrangement shall be made out of 300mm long 25.4mm dia. tube complete with threading and nut-bolts etc. as per approved drawings.
Supplying, Laying, fixing, testing and commissioning of following size XLPE Copper Conductor armoured cable of 1.1 KV grade including cable end-terminations at both ends with brass compression gland and copper lugs etc. complete as required as per specifications. 3x1.5 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6-way double door
S/F of 6A to 32A rating 240/415V ,10 KA,"C" curve MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. 6A to 32A DP
S/F of 6A to 32A rating 240/415V ,10 KA,"C" curve MCB suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. 6A to 32A SP
KASHYAP ELECTRICALS
Star Electric Works
M/s Satyam Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .