Tender Value
Refer Docs
EMD Value
₹29,088
Closing Date
11 Aug 2023, 4:00 pmClosed
SE,SEC,PWD
Office of the Superintending Engineer SOUTHERN ELECTRICAL CIRCLE 2nd FLOOR, MECHANICAL COMPLEX BAGUIATI KOLKATA 700 059.
Construction of proposed G plus 3 storied 100 bedded COVID Hospital with infrastructure works in the premises of the Habra State General Hospital in the district of North 24 Parganas SITC of Fire detection and alarming system
2023_WBPWD_550058_1
WBPWD/SESEC/eNIT-04/23-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Habra
As per NIT
3 documents required · 3 mandatory
₹29,088
Superintending Engineer SEC PWD
25 Aug 2023
21 Jul 2023
14 Aug 2023
21 Jul 2023
11 Aug 2023
28 Jul 2023
26 Jul 2023
Amount
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector IP 54 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable Heat detector IP 54 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make :Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make-Finolex/RR Kable/Polycab/Gloster/Gemscab/Havells ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Supply, Installation,Testing & Commisioning of Microprocessor based addressable fully networkable fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supply, Installation, Testing & Commissioning of Intelligent signal processing unit having Voltage free NO contact which would be connected in series with magnetic coil of AHU power supply unit. In case of Fire, the voltage free contact would close the circuit to isolate the power supply of AHU. (Approved Make: Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
Supply & Laying of OFC for networking with PVC (Make-Finolex/RR Kable/Polycab/Gloster/Gemscab/Havells )conduit including Supply & Fixing complete with all accessories
SITC of Repeater Panel(VDS/UL approved) which will act as an add-on device for remote display of FACP status information of the FDA opearating front releated to the detectors and detectors zones.event messages are displayed via lED collective indicators.Display and opeartion of sections zones with in a building.Individual configurationof the sections and zones to be opearated and displayed via the floor reapeter terminal.Possible to display alarms,pre-alarms,technical messages,faults, isolations from the entire system.Acknoledgement and restting of events (Approved Make: Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Ravel/Honeywell )
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand.
TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done.
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules The defect liability period (DLP) of the aforesaid work will be for the period of THREE (03) years from date of completion.
Creative Projects
Computer Gallery
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .