| 1 | Admitted-Finance 18A PARK STREET 6 0 1 STEPHEN COURT LIFT NO 1 KOLKATA WB 700071 | KOLKATA | KOLKATA | WB | 700071 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical A 52 UPSIDC INDUSTRIAL AREA BULANDSHAHR UTTAR PRADESH 203205 | BULANDSHAHR | UTTAR PRADESH | 203205 | Not Admitted-Fee/PreQual/Technical Others-The bid of M/s Cell Com Teleservices Pvt. Ltd. is being rejected due to non submission of “Bid Security Declaration†as per tender document/NIT. |
| 5 | Rejected-Technical RITHANI DELHI ROAD RITHANI MEERUT UTTAR PRADESH 250103 | MEERUT | UTTAR PRADESH | 250103 | Rejected-Technical Techno-Commercially non responsive bid |
Tender Value
Refer Docs
Closing Date
26 Nov 2021, 5:00 pmClosed
Superintending Engineer(CANDP-I)
SE(CANDP-I), PTCUL Vidyut Bhawan, Near ISBT, Dehradun, Uttarakhand
Construction of 132 kV Overhead D/C Transmission Lines at Rishikesh, Srinagar and Sivai for proposed (Traction Switching Substation) TSS of Rail Vikas Nigam Limited (RVNL)
2021_PTCU1_36340_1
PTCUL/CANDP-I/TL-06/2021-22
Open Tender
Electrical Works
Item Rate
540 days
Srinagar Garhwal
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,600
MD PTCUL
Exempted
Dehradun
31 Mar 2022
10 Sept 2021
27 Nov 2021
10 Sept 2021
26 Nov 2021
1 Oct 2021
27 Sept 2021
Amount
Part-A (Supply of Material )
Towers
Galvanized tower with Bolts, Nuts, flat washers, pack washers & Stub including body extension, leg extension etc.
HT Steel
MS Steel
Galvanized Template
ACSR Panther Conductor
GS Earth wire 7/10 SWG
Single tension fitting for ACSR Panther Conductor suitable for 120 KN Disc Insulator (Complete set including Jumper cone)
Double tension fitting for ACSR Panther Conductor suitable for 120 KN Disc Insulator. (Complete set including Jumper cone)
Tension fitting for GS Earth wire 7/10 SWG
Accessories for conductor & earth wire
Vibration damper for ACSR Panther Conducter
Vibration damper for GS Earth wire 7/10 SWG
Mid span compression joint for ACSR Panther Conductor
Mid span compression joint for GS Earth wire 7/10 SWG
Flexible Copper Bond
Repair Sleeve for Panther Conductor
Repair Sleeve for Earth wire
Disc Insualtor 120 KN
Counterpoise Earthing Set 30 mtr. Long each (4 Nos. for each location)
Miscellaneous Items
Danger Plate
Number Plate
Phase Plate (set of three)
Anti - climbing device barbed wire type
C-wedge (PG) Clamp
Description of Work / Item(s)
Amount
Part-B (Erection of Material )
Survey including Profiling, Tower spotting, Optimisation of Tower locations, Prepration of Tower schedule for 132 KV D/C Line.
Check Survey including peg marking for 132 KV Line
Detailed Soil investigation at proposed tower locations
Earth work in excavation by mechanical/ manual means in benching/revetment work including disposal of surplus excavated soils as directed with all leads & lifts, disposed earth to be neatly levelled and dressed
In ordinary soil/ earth mixed with boulders
In ordinary Rock/DFR/SFR
In Hard Rock
Earth work in excavation by mechanical/ manual means in foundation pits of any size including dressing of sides, ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as backfilling or as directed, including all leads and lifts.
In ordinary soil/ earth mixed with boulders
In ordinary Rock/DFR/SFR
In Hard Rock
Filling available excavated earth (excluding rock) in sides of foundations in layers not exceeding 20 cm in depth, consolidating deposited layer by ramming and watering.
Setting of Stubs, including all foundation work but excluding the cost of concreting and excavation.
B Type Tower (2°-30°)
C Type Tower (30°-60°)
Concrete for foundations including all material, shouring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for M-20 i.e 1:1.5:3 mix concrete (cost of supply MS steel bar is not to be included)
Concrete for foundations including all material, shouring and shuttering if any, forming, concreting and curing of water inlcuding cost of cement for M-10 i.e 1:3:6 mix concrete (cost of supply MS steel bar is not to be included)
Erection of Tower including erection of leg extension, body extension, Bolts & Nuts, Hangers, D-Shackles, Step Bolts, Pack Washers etc. including Tack welding.
Laying, Stringing Tensioning, clamping, jointing etc. complete with ACSR Panther conductor including hoisting of insulators and fitting of vibration dampers etc. for complete route for 132 kV D/C Line.
Laying, Stringing Tensioning, clamping, jointing etc. complete with Single Earthwire 7/10 SWG including fixing of clamps and all accessories.
Grounding work with counter poise type earthing including excavation 0.6 mtr deep and backfilling .(set of 04 no. for each tower)
Installation of Tower accessories
Danger Plate
Number Plate
Phase Plate (set of three)
Anti climbing device (Barbed wire type)
Protection work as per given below
Revetment with rough stones and random rubbles with 1:6:12 cement mortor inlcuding cost of all material, labour and T&P, excavation, back filling, levelling etc.
Cement concretting requried for bottom pad for revetment work in 1:4:8 ratio
Cement concretting requried for top of revetment walls in 1:3:6 ratio
Providing weep holes with 75 mm PVC Pipe (pressure 6 Kg/sqcm in proper slope)
MS Steel Bar for Reinforcement (including supply)
Description of Work / Item(s)
Amount
Total Part-A (Supply ) from BoQ10 sheet WITHOUT GST
Total Part-B(Erection Work ) from BoQ11 sheet WITHOUT GST
Add GST* Amount on (Total of Part-A + Total of Part-B) above
TRANSGLOBAL POWER LIMITED
Coal Mines Associated Traders Pvt. Ltd.
SONAA EINGINEERS PRIVATE LIMITED
Coal Mines Associated Traders Pvt. Ltd.
SONAA EINGINEERS PRIVATE LIMITED
Coal Mines Associated Traders Pvt. Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .