| 1 | L1₹13.4 LAccepted-AOC 22 12 P O SIJUA DHANBAD 828121 DHANBAD 828121 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828121 | ₹13.4 L | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical 22 12 SIJUA DHANBAD 828121 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828121 | - | - | Rejected-Technical Reject |
| 3 | Rejected-Technical ALI NAGAR KABRI PATTI BHULI ROAD DHANBAD JHARKHAND | DHANBAD | DHANBAD | JHARKHAND | 826001 | - | - | Rejected-Technical Reject |
Tender Value
₹15.9 L
EMD Value
₹19,900
Closing Date
13 Mar 2026, 6:00 pmClosed
AREA MANAGER (ENM) KATRAS AREA
OFFICE OF THE GENERAL MANAGER BCCL KATRAS AREA IV ENM DEPT. Post-SIJUA PIN-828121 JHARKHAND
(1) REPAIRING AND CHANGING OF OLD AND DAMAGED CONDUCTOR OF KP-II FEEDER,6.6 KV OVER HEAD LINE FROM RAMKANALI R/S TO KANTAPAHRI S/STATION RAMKANALI COLLIERY FILTER PLANT S/STATION AREA.
2026_BCCL_355347_1
BCCL/KA/IV/ENM/E-TENDER/ 25-26/183 DATE- 03.03.2026
Open Tender
Electrical and Maintenance Works
15 days
AKWMCAND ASGKCC KATRAS AREA IV
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,900
29 Mar 2026
3 Mar 2026
14 Mar 2026
3 Mar 2026
13 Mar 2026
3 Mar 2026
3 Mar 2026 - 6 Mar 2026
ITEM DESCRIPTION / HEADLING
(1) REPAIRING AND CHANGING OF OLD AND DAMAGED CONDUCTOR OF KP-II FEEDER,6.6 KV OVER HEAD LINE FROM RAMKANALI R/S TO KANTAPAHRI S/STATION & RAMKANALI COLLIERY FILTER PLANT S/STATION KATRAS AREA.:- SUPPLYING AND ERECTION OF STAY SET COMPLETE(GALVANISED)WITH 19/20MM DIA X1.8 MTRS LONG STAY ROD AS REQUIRED.(12.1)
SUPPLY & ERECTION OF STAY WIRE & STAY INSULATOR.
DISMANTLING OF WOLF CONDUCTOR 20 SPAN X 70 MTR X 3 = 4200.
SUPPLYING AND ERECTION OF 11KV DISC INSULATOR FOR 11 KV OVER HEAD LINES WITH GALVANIZED INSULATOR FITTING,BALL AND SOCKET TYPE AND COMPLETE WITH GALVANIZED STRAIN CLAMPS,BOLTS,NUTS,WASHERS ETC.AS REQUIRED(13.11)
SUPPLYING AND ERECTION OF 11KV PIN INSULATOR COMPLETE WITH LARGE STEEL HEAD G.I PIN,NUTS,WASHERS ETC.AS REQUIRED.(13.10)
ERECTION OF ACSR(WOLF) CONDUCTOR INCLUDING BINDING ETC. AS REQUIRED.20 SPAN X 70 MTR X 3 =4200
SUPPLYING AND ERECTION OF CRADLE GUARD 480 MTR(10 SPAN) (a) SUPPLY OF G.I WIRE NO.8 SWG
(b) ERECTION OF CRADLE GUARD AS REQUIRED(12.28 ERCGD)
SUPPLYING AND ERECTION OF EARTH WIRE 3000 MTR.(a) SUPPLY OF G.I WIRE SWG
(b) ERECTION OF G.I WIRE NO.8 SWG INCLUDING BINDING ETC.AS REQUIRED.(12.25 PAGE NO.39)
CUTTING OF BUSH AND TREE BRANCHES(4 HEAD X 12 SHIFT)
SUPPLY OF BULL DOG(U BOLT CLAMP)
REFRESH REPAIR FIXING OF OLD AND DAMAGED JUMPHER.
(2) REPAIRING AND CHANGING OF OLD AND DAMAGED CONDUCTOR OF KP-II FEEDER,11KV OVER HEAD LINE FROM RAMKANALI R/S TO KANTAPAHRI S/STATION KATRAS AREA.:- SUPPLYING AND ERECTION OF STAY SET COMPLETE(GALVANISED)WITH 19/20MM DIA X1.8 MTRS LONG STAY ROD AS REQUIRED.(12.1)
'SUPPLY & ERECTION OF STAY WIRE & STAY INSULATOR.
'DISMANTLING OF WOLF CONDUCTOR 21 SPAN X 70 MTR X 3 = 4410.
'SUPPLYING AND ERECTION OF 11KV DISC INSULATOR FOR 11 KV OVER HEAD LINES WITH GALVANIZED INSULATOR FITTING,BALL AND SOCKET TYPE AND COMPLETE WITH GALVANIZED STRAIN CLAMPS,BOLTS,NUTS,WASHERS ETC.AS REQUIRED(13.11)
SUPPLYING AND ERECTION OF 11KV PIN INSULATOR COMPLETE WITH LARGE STEEL HEAD G.I PIN,NUTS,WASHERS ETC.AS REQUIRED.(13.10)
'ERECTION OF ACSR(WOLF) CONDUCTOR INCLUDING BINDING ETC. AS REQUIRED.21 SPAN X 70 MTR X 3 =4410 MTR.
'SUPPLYING AND ERECTION OF CRADLE GUARD 480 MTR(10 SPAN) (a) SUPPLY OF G.I WIRE NO.8 SWG
'(b) ERECTION OF CRADLE GUARD AS REQUIRED(12.28 ERCGD)
'SUPPLYING AND ERECTION OF EARTH WIRE 3000 MTR.(a) SUPPLY OF G.I WIRE SWG
(b) ERECTION OF G.I WIRE NO.8 SWG INCLUDING BINDING ETC.AS REQUIRED.(12.25 PAGE NO.39)
'CUTTING OF BUSH AND TREE BRANCHES(4 HEAD X 12 SHIFT)
SUPPLY OF BULL DOG(U BOLT CLAMP)
REFRESH REPAIR FIXING OF OLD AND DAMAGED JUMPHER.
(3) MODIFICATION OF 9 NO.FEEDER 6.6 KV OVER HEAD LINE NEAR V SEAM S/STATION TO PANCHMUKHI MANDIR OF SALANPUR COLLIERY UNDER KATRAS AREA.:- (ERECTION) - TRANSPORTATION OF RAIL POLE.(M.R)
ERECTION OF RAIL POLE.
SUPPLY OF CHANNEL IRON 75MMX40MMX6MM CROSS ARM FOR TWO 11 KV OVER HEAD LINE CONDUCTOR COMPLETE WITH 50MMX50MMX6MM ANGLE IRON BRACKET WELDED TO CHANNEL IRON.
SUPPLY OF CHANNEL IRON 75MMX40MMX6MM POLE TOP BRACKET FOR SINGLE 11KV OVER HEAD LINE.
ERECTION OF POLE TOP STRAIGHT TWO WIRE/ANGLE IRON/CHANNEL IRON,CROSS ARM ON POLE AS REQUIRED.
SUPPLY OF TWO LENGTH OF CHANNEL IRON 75MMX40MMX6MM DOUBLE POLE CROSS ARM FOR THREE WIRE CROSS ARM.
ERECTION OF DOUBLE POLE 3 WIRE CROSS ARM.
SUPPLY & ERECTION OF 11 KV DISC INSULATOR.
SUPPLY & ERECTION OF 11 KV PIN INSULATOR.
SUPPLY & ERECTION OF STAY SET.
ERECTION OF ACSR DOG CONDUCTOR I 1200 MTR X 0.394 KG/MTR.
SUPPLY OF 8 NO.G.I WIRE.
ERECTION OF G.I WIRE NO.8 SWG INCLUDING BINDING.
ERECTION OF CRADLE GUARD AS REQUIRED.
SUPPLY OF 25MM "U" BOLT.
CUTTING OF TREE BRANCHES AND BUSHES( 4 HEAD X 03 SHIFT)
DISMANTLING :- DISMANTLING OF DOG CONDUCTOR 1800 MTR.
DISMANTLING OF BROKEN DISC INSULATOR 12 NOS.
DISMANTLING OF BROKEN PIN INSULATOR 12 NOS.
DISMANTLING OF IRON MATERIALS.
DISMANTLING OF POLE IN C.C.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.39 MB
BOQ_368197.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid