Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC 12 MANAULI HOUSE AMBALA CITY 134003 HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC Being lowest reasonable | |
| 2 | L2₹43.5 L+₹53,644.50 (1.25%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹97,200
Closing Date
28 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HALWARA
GE (AF) HALWARA
REPAIR REPLACEMENT TO ELECTRICAL SYSTEM AND GADGETS AT AF STATION HALWARA
2020_MES_399526_1
GE/HAL-60/2020-21
Open Tender
Civil Works
Item Rate
183 days
GE (AF) HALWARA
MES ENLISTED CONTRACTORS CLASS D CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) HALWARA
₹97,200
Yes
31 Dec 2020
1 Dec 2020
30 Dec 2020
1 Dec 2020
28 Dec 2020
14 Dec 2020
60 days
Amount
Dismantling of old unserviceable unit up to 200 Amp Load of Old existing protection device 3 phase 4 wire complete including replacement of the switching air break contactor 02 Numbers 3 pole type of load handling capacity not less than 200 Amps ( LL) with 02 Numbers DC contactor 25 Amps operating voltage 12/ 24 volts DC also comprising automatic battery charger 12 volt/24 volt 15 amps with auto cut off at 13.2/ 27 volts including delivering UNINTERUPTED 220 volts AC 100 watts output & Automation with restoration of electric supply with in 05 seconds (I) If the mains fail, or one or more phase of mains is not available. If any phase voltage of mains is out of present limits however there should be a provision to set the limits of higher and lower phase voltages Microprocessor server type password protected with concurrence of Eng.-In-Charge and GE as per the site requirement. The mains supply with in this range shall be considered as healthy so as to avoid continuous running of Engine Alternator Set. Switch the load to the engine supply after suitable time delay, after starting the engine on mains failure/phase failure / low voltage / high voltage. Switch the load back to the mains supply after suitable time delay, when healthy mains supply is restored and stopping the Engine. Attempt to start the Engine up to three times on failure of earlier attempts with suitable time intervals. , with automatic temperature controller built with 02 numbers 6 inch cooling fans with proper installation at LT panel as directed by Engg-in-Charge provide following settable features :- (a) Mains failure time - to initiate automatic EA start after 0 to 300 seconds of mains failure. (b) Mains restore time - to initiate automatic stop of EA after 0 to 300 seconds of mains in stable conditions. (c) Low oil pressure delay time - 0 to 99 seconds delay of the low pressure oil input alarm from engine start. (d) Stop solenoid time - 10 to 99 seconds enabling time for "stop solenoid". (e) Cranking up time - 0 to 99 seconds enabling time for starter. The timer is reset if the engine starts before the programmed time. (f) Start attempts - 1 to 3 numbers of automatic attempts during automatic start cycle (g) Attempts interval - 1 to 99 seconds time interval between starting pulse attempts. (h) Cooling down time - 0 to 300 seconds engine cooling time before stopping. During this time the engine runs without load. (I) Generator voltage time - time of stable generator voltage to close EA contactor to load (0 to 300 seconds). Multifunctional meter to indicate Voltage, Current, PF, Frequency & kWh of DG Set. including SAFETY CONTROL. Stop fault . Start fault . Engine Temperature high . Alternator fault . BTS battery low . Mains ok / mains faulty Overload . Over / under voltage Under /Over Frequency also including S/I/T/C of 02 sets Resin Casting current Transformers one for input and second for output load 3 phase 4 wire 03 of 15 VA burden 1100 volts insulation FUNCTION Limit the Inrush Current, Improve the THD/PF at Light Load or High Line, Improved Stability with a Type 2 Compensation Network--Phase Unbalance, Auto Phase Reversal tripping suitable for suitable load as per site requirement , Phase Missing Under Voltage and Over Voltage Monitor and Control, Neutral Open Protection. ALSO SPECIAL ZERO CROSSING SWITCHING OPERATION PROTECTION SYSTEM BUILT Phase Un balance (1 to 20%) (Adjustable) Power consumption 15VA / 3W Setting Accuracy voltage ± 4V, Minimum setting current 0.5A, Maximum setting current =5A (Above 5A - external CT setting max.1000/5 in steps of 5), Setting Accuracy Current ± 5% of full scale ±1digit, Trip time delay1 to 250secs settable for UB, OV, UV , UC & OC, Trip time accuracy± 1% of set delay ±2sec., Trip setting, Phase failure 3 sec Max. factory set., Phase Reversal Auto tripping, Phase Un balance1 to 20% (Adjustable), Under Voltage and over voltage 5V to 60V AC (Adjustable Individually ), Recovery Time2 sec Min Power On Delay10 sec Max., Service life(under no load) 10Lakh operations minimum , Electrical life, (under full load) 10 Lakh operations minimum with Micro processor based approved by GE minimum ISO 9001:2015 Certified . Note :- The Entire work at SPIDER, LRQRM, S4, MATRA & NBD sites are to be executed only by OEM approved by GE
Dismentaling of Old Protection u/s relay & S/I/T/C Of Automatic voltage & Frequency display & Micro programmer protection device 3 phase ( 88 -264 ) Volts unit ( 45 Hz-- 55 Hz ) Adj Finger touch proof terminals for voltage and current connections. Communication with PCs, PLCs, DCS through optional RS 485/232 serial interface. Potential free output with programmable trip time for protection. Displays the reasons for tripping for future correction. Auto-scaling of Kilo, Mega, Giga and decimal point. Auto scrolling. Displays more than 25 parameters Basic (VLL, VLN, A, Hz); Power (W, VA, PF) and Energy (kWh, Load Hours). User programmable password protection. Clearance & creepage distance meets UL 61010 safety standard. Programmable start time from sensing safe condition. Programmable locked rotor current and time. Specification Description Input Voltage: Input Current: Aux-Supply: Technical Specification: Sensing/ Measurement: True RMS, 1 Sec update time. 4 Voltage inputs (V1 V2 V3 VN)); Programmable 110 or 415V LL Nominal (Range 80-550V LL) Primary Programmable up to 999 kV Burden: 0.2VA Max. per phase. Current inputs (A1 A2 A3) 50mA - 6A (Field configurable 1A or 5A) Primary Programmable up to 99 kA Overload: 10A max continuous, 50A max for 3 sec. Burden: 0.2VA Max. per phase. (Control Power): 80 - 300V AC/DC. Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per IEC 62053-22 (Optional). Two field configurable parameter for continuous display. Intelligent power save mode. Displays ON hours , Load hours & number of interruption. Graphical display. Single solutions for protection of motors/equipment against voltage, overload, frequency, PF, single phasing, unbalance loading of voltage and current, neutral current, & phase reversal. Programmable (intelligent inverse time) trip time for Volts/Overload/Hz/PF/Neutral current. Programmable relay status High or Low for safe; 2 relays for alarm and trip. Detect winding shorts. Continuous Wh display even in Auto-scrolling mode. Safe/Alarm/Trip indication for online view. Manual re-correction after the trip. Neutral current display and protection. Simultaneous display of 7 parameters. Accuracy: TRIP, Load Pattern. SAFE REGION Start Delay Programmable Programmable Relay Status UNSAFE REGION Time Alarm Relay for Warning Intelligent tripping based on load Off time Parameter like under/over Volts, Amps, Frequency, PF, Unbalance loading of Voltage/Current, Neutral current, Single phasing OFF TIME Variable Communication RS485 interface: Parity: Odd, Even, None (Prefered Even) Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps). Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Mechanical Specification: equiped with BUILT IN Surge voltage arrester consisting of base element with remote indicator contact and ground connectors, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 3 + 1 circuit protection With floating remote indication contact Multi-channel type 2 arresters Optical, mechanical status indication for the individual arresters Type 2 consistent plug-in surge arresters Mechanical coding of all slots Disconnect device on each individual plug , Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 IEC power supply system TN-S TT Mode of protection L-N L-PE N-PE Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 4 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 240/415 V AC (TN-S) 240/415 V AC (TT) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous operating voltage UC (L-N) 275 V AC Maximum continuous operating voltage UC (L-PE) 275 V AC Maximum continuous voltage UC (N-PE) 260 V AC Rated load current IL 80 A Residual current IPE ≤ 5 µA Standby power consumption PC ≤ 360 mVA Nominal discharge current In (8/20) µs 20 kA Maximum discharge current Imax (8/20) µs 40 kA current interrupt rating Ifi (N-PE) 100 A Short-circuit current rating ISCCR 25 kA Voltage protection level Up (L-N) ≤ 1.35 kV data Protective circuit Voltage protection level Up (L-PE) ≤ 1.6 kV Voltage protection level Up (N-PE) ≤ 1.5 kV Residual voltage Ures (L-N) ≤ 1.35 kV (at In) ≤ 1.1 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (L-PE) ≤ 1.6 kV (at In) ≤ 1.2 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (N-PE) ≤ 0.4 kV (at In) ≤ 0.25 kV (at 10 kA) ≤ 0.15 kV (at 5 kA) ≤ 0.1 kV (at 3 kA) TOV behavior at UT (L-N) 335 V AC (5 s / withstand mode) 440 V AC (120 min / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / withstand mode) Response time tA (L-N) ≤ 25 ns Response time tA (L-PE) ≤ 100 ns Response time tA (N-PE) ≤ 100 ns Max. backup fuse with V-type through wiring 80 A (gG) Max. backup fuse with branch wiring 125 A (gG) Indicator/remote signaling Switching function PDT contact Operating voltage 5 V AC ... 250 V AC 30 V DC Operating current 5 mA AC ... 750 mA AC 1 A DC Connection method Plug-in/screw connection via COMBICON Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm² ... 1.5 mm² Conductor cross section solid 0.14 mm² ... 1.5 mm² Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection. Make havells/CITEL/ABB/SCHNEIDER/PHONIX along with Phase under/over voltage, (AND & OR mode) , Positive sequence under voltage, Negative sequence overvoltage, Residual over voltage / Derived Vo sequence overvoltage, Voltage transformer supervision, Under/over frequency, Rate of change of Frequency (df/dt+t) (Make:- L&T/ ABB/ SCHNEIDER/ PARTNER )
Dismentaling & S/I/T/C of 3 phase 3 wire Capacitor for load 315 KVA - 40KVAR , Reducing peak KW billing demand , Increased system capacity and reduced system losses , Increased voltage level in electrical system to cover up line lossed in HT O/H or Underground type with over voltage 5V to 60V AC (Adjustable Individually ), Recovery Time2 sec Min Power On Delay10 sec Max., Service life(under no load) 10Lakh operations minimum , Electrical life, (under full load) 10 Lakh operations minimum with PROTECTION SYSTEM to tripp of exisiting MCCB if power factor leads 1.1 Programmable THD protection, Programmable Discharge Time MAKE ABB/ BCH /SIEMENS/L&T/ NEPTUNE/PARTNER
Dismentaling & S/I/T/C of 3 phase 3 wire Capacitor for load 200 KVA - 30KVAR , Reducing peak KW billing demand , Increased system capacity and reduced system losses , Increased voltage level in electrical system to cover up line lossed in HT O/H or Underground type with over voltage 5V to 60V AC (Adjustable Individually ), Recovery Time2 sec Min Power On Delay10 sec Max., Service life(under no load) 10Lakh operations minimum , Electrical life, (under full load) 10 Lakh operations minimum with PROTECTION SYSTEM to tripp of exisiting MCCB if power factor leads 1.1 Programmable THD protection, Programmable Discharge Time MAKE ABB/ BCH /SIEMENS/L&T/ NEPTUNE/PARTNER
Dismentaling of old mechanical sytem with proper shut down & repaire/ servicing of entire tap changer assembly unit with Vector Group YNyn0, ON-load Tap motion generator anticlockwise and clockwise on HV side to vary secondary voltage from (+) 5% TO (-) 15% in steps of 1.25%, HV / Dielectric strength not less than 45KV at 2.5 mm, Digital MICROPROCESSOR CARD along with upgrading the existing RTCC panel includingcomplete servicing / replacement of necessary parts IC, resistance of existing Relay with new AVR Relay ( MAKE : 1SO 9001:2015 CERTIFIED ) , having following specification :- The RTCC shall be upgraded such that it will maintain electrical properties, even under severe overload, under/over voltage and under/over frequency conditions. Input correction range shall be -30% to +20% of nominal input voltage. Upon turn on or restart, the output of the 33/11 KV TFR shall not exceed the specified output regulation limits. if the input voltage or frequency exceeds programmable minimum or maximum set points for a programmable time period (factory set for 10 seconds),When electrical parameters are back within acceptable limits for a programmable time period (factory set for 60 seconds), the output voltage is outside of acceptable programmed limits, the RTCC must give output command to electronically operate connected system.. Response Time: RTCC Line Voltage Regulation and Correction Time: Output regulation shall be +5%, -6%, given an input voltage variation of -30% to +30% for nominal, when within +/-5% of the nominal frequency. Load Regulation: No load to full load regulation shall be 3% typical under linear loading. Note: The existing RTCC shall be adjusted so that the combination of line voltage regulation and linear load regulation results in a maximum output voltage variation of +7% to -8% from nominal, when within +/-5% of the nominal frequency. Operating Frequency: The existing RTCC shall be capable of operating at +10% to -15% of the nominal frequency, 50Hz or 60Hz, with programmable high and low limits to alarm and electronically shut down the SF6 Breaker. Limits shall be set to +/-2Hz from nominal and electronic shutdown shall occur if limits are exceeded for 10 seconds. Once back within limits for a programmable time period of 60 seconds, the SF6 Breaker shall automatically restart.
M/S SANGA SINGH AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .