Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.8 LAccepted-AOC | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹3.1 L+₹34,449 (12.4%)Rejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | 2 | Rejected-Finance L2 | |
| 3 | 3₹3.6 L+₹86,500 (31.1%)Rejected-Finance | 3 | Rejected-Finance L3 |
Tender Value
₹3.1 L
EMD Value
₹6,203
Closing Date
21 Aug 2023, 10:00 amClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,CSPZ
Provision of Lighting Arrangement with New Led Fittings at Community Hall Mirdard road in ward no.77 under city City S.P. Zone
2023_MCD_164268_1
MCD/TR/3334/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
30 days
City- SP, DELHI GATE
2 documents required · 2 mandatory
₹590
₹6,203
7 Oct 2023
11 Aug 2023
21 Aug 2023
11 Aug 2023
21 Aug 2023
12 Aug 2023
Amount
Electrical Work
121.1:Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
1.8.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.15.3:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
OD2291/2023-2024:SITC of Single phase Monoblock Pump SetComplite With all accsories Workable on 240/415 V,50 Hz AC supply (a)1 Hp (0.75 kw) single phase pump set,head fro 12-30 meter Suction and Delivery 25X25mm.
OD2293/2023-2024:P/F ABC (aluminium Phosphate) power type fire extinguisher 6 kg capacity complete in all respect wit ISI mark i/c fixing arrangement etc as required.
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.16:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
Electrical Work
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.36:SITC of 10W surface/wall mounted LED Bulkhead factual impact dust and water resistant luminaires with IP 65/66 protection
122.2.37:S/I/T/C of Recess mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/surface with connections as reqd.(a)Total system wattage = 36 watt +/- 5% (b)Luminus efficacy >=95 lumens /watt. (c)Power factor >=0.95
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.111:supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
bharat electricals & electronics
PRINCE ENTERPRISES
Bidder Name
M/s Gyan Enterprises
PRINCE ENTERPRISES
bharat electricals & electronics
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .