Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | ₹2.9 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.9 LRejected-AOC | ₹2.9 L | L2 | Rejected-AOC Second lowest |
| 3 | L3₹3.3 LRejected-Finance | ₹3.3 L | L3 | Rejected-Finance 3rd lowest |
| 4 | L4₹3.2 LRejected-Finance ST ANTONYS ELECTRICALS ALAPPUZHA PAMPADY BLOCK PANCHAYAT 06012467 PUSHPA NARAYANAN 0601 DISTRICT TREASURY ALAPPUZHA | ₹3.2 L | L4 | Rejected-Finance 4th lowest |
| 5 | L5₹3.6 LRejected-Finance ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | ₹3.6 L | L5 | Rejected-Finance 5th lowest |
Tender Value
Refer Docs
EMD Value
₹7,924
Closing Date
18 May 2026, 3:00 pmClosed
Assistant Executive Engineer
PWD Electrical subdivision Kottayam
GENERALSuperintendent office of Resurvey at Mini Civil station Pala Rewiring of the office and providing e office facilities Electrification General Electrical Work
2026_PWD_849573_1
ESDK_ET_1_2026-2027
Open Tender
Electrical Works
300 days
Pala
Please refer Tender documents.
10 documents required · 10 mandatory
₹700
₹7,924
23 Jun 2026
7 May 2026
20 May 2026
7 May 2026
18 May 2026
7 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Electrification | ||||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,689.22 | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | - | each | 99.8 | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,273.18 | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket
Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,331.08 | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | - | each | 424.29 | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | - | each | 2,244.96 | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | - | each | 187.04 | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | - | each | 60.24 | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell | - | each | 198.29 | - | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1435561.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
viewsbd.pdf
Tender Documents • 2.00 MB
BOQ_1435561.xls
BOQ • 0.36 MB
Specificcondition.pdf
Additional Documents • 0.03 MB
LISTOFMATERIALS.pdf
Additional Documents • 0.20 MB
Download all tender documents and submit your bid