| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC CG 44 SECTOR 2 SALT LAKE CITY KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.5 L+₹53,675 (13.7%)Rejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.5 L+₹58,258 (14.8%)Rejected-Finance 6201 M G ROAD KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L3 | Rejected-Finance L3 | |
| 4 | L4₹4.6 L+₹65,093.20 (16.6%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹5.0 L+₹1.0 L (26.2%)Rejected-Finance 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹9,744
Closing Date
25 Sept 2024, 3:00 pmClosed
Assistant Engineer, BESD-II, R-13 Purta Bhavan
Assistant Engineer, BESD-II, R-13 Purta Bhavan
Annual Maintenance of Electrical Installation at Bikash Bhawan Shifting and reinstallation of AC machines for emergency demolition and restoration work at West Side of East Block from ground to 05th floor
2024_WBPWD_752438_1
WBPWD/AE/BESD-II/e NIQ 05/2024-25
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
Bikash Bhavan
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,744
3 Oct 2024
17 Sept 2024
27 Sept 2024
18 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Dismantling of 1.5 ton/ 2.0 ton Air Conditioner outdoor unit (Split type, Cassette type) after gas locking arrangement with necessary tools & tackels and store in safe place & Re-installation the same of 1.5 ton/ 2.0 ton Air Conditioner outdoor unit with necessary arrangement as per direction of EIC
Supply & Fixing of 1.5 / 2.0 Ton Split/ Cassette type Air Conditioner Outdoor Unit Mounting Bracket, Angle Height 450 MM / Bracket Lenght 485 MM with 50 mm fastner with nut & bolts as per direction of EIC. (Make: Panasonic/Monitor/Hitachi/ Daikin)
SITC incl. vacuumization and Nitrogen of testing of following nominal size of soft/hard drawn Cu. refrigerant piping for Pac/ VRV/VRF/RAC system, complete with fitting, with adjustable ring type hanger supports, jointing/brazing incl. accessories, insulated with XLPE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 5/8”(15.88 mm)dia(Soft drawn) Cu. Pipes(As per standard BS864 or ANSIB 16.22)incl. 19 mm thick insulation.
1/4” (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply and laying PVC Drain Pipe 25mm dia with 6 mm thick Nitrile Rubber Insulation. [Make:- Suprime/Oriplast]
Supply and laying of 1.1 kV grade copper unarmoured round cable of 3 core 2.5 sq. mm from IDU Unit to ODU Unit for the above mentioned AC Unit. [Make:- Polycab/Havells/Gloster/Finolex/KEI/RR Kabel/As per choice of EIC]
Supply & Filling of different type refrigerant gas given below: R-32 Gas/ R-22 Gas/ R-410 Gas/ R-410-A/R-290 Gas (Make: Godrej/ Floron/Mafron)
Supply & Fixing of 240V to 400V, +_ 5% tolerance, 40-50 MFD/ 50-60MFD, P2 type capacitor for different types of existing split AC machines. (Make: Saroda/Epcos)
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
(b) Extra for additional 3.6 height or part there of
(Note :- Rate should be quoted inclusive of all taxes and duties including G.S.T.)
ANIKET COOLING AND REFRIGERATION CO (BID ID -5624788)
SUMAN ENTERPRISE (BID ID -5624219)
SUPARNA REFRIZARATION (BID ID -5624755)
WEATHER MAKERS INDIA (BID ID -5629252)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .