| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC Award |
| 2 | L2₹2.0 Cr+₹25.7 L (14.5%)Rejected-AOC | ₹2.0 Cr+₹25.7 L (14.5%) | L2 | Rejected-AOC Reject |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
30 Sept 2020, 10:00 amClosed
Executive Engineer, PHED No. 1 Gohana
Executive Engineer, PHED No. 1 Gohana Near MC Park Jind Road Gohana
GANGANA TANDIA PANA ESTIMATE FOR PROVIDING FHTC AND BALANCE DISTRIBUTION PIPE LINE AND AUG. OF WW BY RENOVATION OF EXISTING STRUCTURES OF WATER WORKS IN VILLAGE GANGANA TANDIA PANA GR.OF 2 NOS. VILLAGE GANGANA TANDIA PANA , GANGANA PADRA PANA
2020_HRY_145581_1
EIC Memo No. 82036-PHE/Mont dt. 22-09-2020
Open Tender
Civil Works
Works
365 days
Village Gangana Tandia Pana
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
Executive Engineer, PHED No. 1 Gohana
₹3.4 L
24 Nov 2020
24 Sept 2020
30 Sept 2020
24 Sept 2020
30 Sept 2020
24 Sept 2020
Amount
WATER TREATMENT PLANT (WTP) Design, construction, testing & commissioning of 1.00 MLD capacity Water treatment plant at Water Works Gangana including inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, pumping machineries and electric cabling, control panels, entire piping network of suitable size DI pipe from S & S Tank to Pump chamber, raw water pump to inlet box of WTP, WTP to CWT & Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (Sluice valves of make IVC/VAG) .
Supply & Erection of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No. II complete in all respect withpriming arrangement with complete base frame.-PUMPING MACHINERY AT SUMP WELL -Clear Water Pump set : 3000 LPM, 25 mtrs head (30.00 BHP) with squirrel cage induction motor 1440 RPM, 3 phase 50 Hz of Four Star rating
PUMPING MACHINERY AT BOOSTING STATION GANGANA HUDDA WALA-Clear Water Pump set : 400 LPM, 25 mtrs head (7.50 BHP) with squirrel cage induction motor 1440 RPM, 3 phase 50 Hz of Four Star rating
PUMPING MACHINERY AT BOOSTING STATION GANGANA TANDIA PANA-Clear Water Pump set : 400 LPM, 25 mtrs head (7.50 BHP) with squirrel cage induction motor 1440 RPM, 3 phase 50 Hz of Four Star rating
Supply and fixing following CI D/F pipe and specials/ sluice valves /non return valves/ bell mouth/Reflex valves including cost of Jointing materials, laying, jointing, in position as per specification given in schedule No.II A) Detail of pipe and specials (FOR PUMPING MACHINERY and Inlet Outlet Connections )- (i) - CI D/F Pipe 200mm i/d
Supply , erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items A) For raw water pump sets for 3000 LPM x 25 mtr. head = 2 nos. a) Main switch 100 Amp 2 Nos.(L&T,Siemens,ABB) b)Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?L&T) c)Amp.mtr. 100x100mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d)CT 100/1 No. (AE/KAPPA/L&T) e)VSS 1 No. & ASS 2 Nos. each of approved make f)SPP 1 No. approved make g)Motor starter , star delta 2 Nos. for 3000 LPM x 25 mtr. head motor (L&T, Siemens, ABB) h)Capacity of suitable capacity = 2 Nos. i)Indicating Lamp- One Set j)Change over switch Amp. = 1 No.
Supply , erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items A) For raw water pump sets for 400 LPM x 40 mtr. head = 2 nos. a) Main switch 100 Amp 2 Nos.(L&T,Siemens,ABB) b)Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?L&T) c)Amp.mtr. 100x100mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d)CT 100/1 No. (AE/KAPPA/L&T) e)VSS 1 No. & ASS 2 Nos. each of approved make f)SPP 1 No. approved make g)Motor starter , star delta 2 Nos. for 400 LPM x 25 mtr. head motor (L&T, Siemens, ABB) h)Capacity of suitable capacity = 2 Nos. i)Indicating Lamp- One Set j)Change over switch Amp. = 1 No.
Supply , erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly slouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm having following items A) For raw water pump sets for 400 LPM x 40 mtr. head = 2 nos. a) Main switch 100 Amp 2 Nos.(L&T,Siemens,ABB) b)Volt Mtr. 100x100mm range 0 to 500 volt 1 No. (AE/KAPPA?L&T) c)Amp.mtr. 100x100mm range 0 to 100 Amp. 2 Nos. (AE/KAPPA/L&T) d)CT 100/1 No. (AE/KAPPA/L&T) e)VSS 1 No. & ASS 2 Nos. each of approved make f)SPP 1 No. approved make g)Motor starter , star delta 2 Nos. for 400 LPM x 25 mtr. head motor (L&T, Siemens, ABB) h)Capacity of suitable capacity = 2 Nos. i)Indicating Lamp- One Set j)Change over switch Amp. = 1 No.
Supply erection, testing of I.S.I. marked copper wire for 2 Nos. motors with under ground system in PVC and flexible pipes copper wire 6 sq.mm complete in all respect with accessories like thimble etc. complete in all respects.
Supply erection, testing of ISI marked copper wire for 1 No panel boards from main switch to panel and wiring of panel with size 10 sq.mm (copper wire) ISI marked complete in all respects with accessories like thimble etc. complete in all respect. - 10mm2 3core
16mm2 3core
Supply erection, testing of light fittings including wire in the Pump chamber with material upto 10 points including switch, button, plug, PVC conduct pipe & copper wire etc. as per approved specifications complete in all respect.
Providing and fixing Ceilling fan 1400mm (56") with speed adjuter of reputed make (Make Crompton, Usha, Bajaj, Orient) complete in all respect.
Prov. & fixing LED Light 100 Watt with GI pipe with nut & bolt make havells complete in all respect.
Prov. & fixing sign board of size 5'x4' with iron angle embedded in cement concrete 1:2:4 complete in all respect.
Prov. & fixing Diesel Generating Set of 40 KVA complete in all respect.
Design, Supply & Erection of copper wound outdoor type Transformers of required KVA as mentioned below on load tap changer or suitable capacity on higher side of standard make outdoor type, VCB Panel, G.O. Switch, H.T. Metering Panels, alongwith APFC Panels for each Transformer, 11KV Substation, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including operation & Maintenance of 5 Years (2 Nos. Transformer 15 KVA) (At 2 Nos. Boosting Station )
Operation & Maintenance for complete scope of work mention in the DNIT (Disinfection material supplied by the PHED) as per schedule –IV for a period of 5 years after 12 months during defect liability period 3 month trial run (will be charged to the A/ mtc estimate) - (i)Operation and maintenance during defect liability period (Operation only)
(ii) Operation & maintenance during defect liability period 1st year
(iii) Operation and maintenance during 2nd year
(iii) Operation and maintenance during 3rd year
(iv) Operation and maintenance during 4th year
(v) Operation and maintenance during 5th year
Bidder Name
Amount
RAM PHAL SINGH CONT
Rajbir Singh Hooda
RAM PHAL SINGH CONT
RAM PHAL SINGH CONT
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .