The Superintending Engineer, Project Implementation Unit
SITC of New Mortuary Cabinet Installation & E.I Work in PM Room at GMERS Hospital Himmatnagar, Ta.Himmatnagar, S.D.H. Idar,Ta.Idar & S.D.H. Khedbrahma,Ta.Khedbrahma, Dist:Sabarkantha. [2ND ATTEMPT]
267422
141/04 OF 2025/2026
Open
Electrical
Gandhinagar
9 documents required · 9 mandatory
₹2,400
Yes
PIU-General Fund A/c 11-114
₹60,000
Yes
20 Jan 2026
20 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
SITC of 42 Body Mortuary Cabinates with electrical installations at existing PM room in GMERS Hospital Gotri Vadodara
Sr no. Item No. Description Qty. Unit Net Rate In Words Amonut
Providing and erecting Inverter based approved make split air-conditioning unit
consisting of condensing unit with variable speed fan motor, inverter type
hermetically sealed rotary compressor with accessories etc. duly connected Rupees Forty One
separately erected evaporating unit and blower motor with its accessories by Thousand Seven Hundred
means of extra supplied proper insulated copper tubing,drain PVC pipes Twenty Five and Twelve
suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Paisa Only
Remote Control & MS Stand) with necessary core cutting. (1)For ISEER Range
(KWH/KWH)(3.1 to 3.99) (B) for 1.5 ton capacity
Supplying and erecting insulated pair of soft copper tubing open or concealed Rupees Nine Hundred Sixty
2 2 including power and control cable,necessary PVC drain pipes for Split AC 20 RMT. 965.56 Five and Fifty Six Paisa
machine up to 4 TR capacity Only
Suppy, Installation, Testing and Commisioning of 6 body mortuary cabinate of
approx. Force draft type PUF Panel: 80mm thick PUF panel with both side S.S -
304 grade sheet of 0.5 mm thickness & PUF density should be 40 kg/m3 Drawer
Tray: Made with high grade SS 304 box pipe. MS powder coated trolly
mechanism along with ancillary material SS Tray, Temperature: -8 C to +8 C,
Door: Overlap type door with heavy duty hinges & Handles with closer along
with push type gasket for easy operation Size: 32” X 32”, Lock SS: Individual lock
& Key for each door, Identification: Each Window should be facilitated for Body
Identification tag (replaceable),Vapor proof lights, Refrigeration System: Air
Cooled, Split Type and Capable to run at minimum 45 deg C Ambient with CFC Rupees Five Hundred
free refrigerant gas R407C/R404A for low maintenance. Compressor Type : Ninety Thousand Only
Hermetic reciprocating/scroll type compressor, Indoor Unit: SS tube & Copper
fins type Indoor Unit with SS casing capable to maintain low relative
humidity.Refrigerant Pipe IDU to ODU up to 5 mtr :SS/Copper inner grooved,
Power: 415 V, 3 Ph, 60 Hz, Temperature achievement and retention : Ref.
System should be able to achieve temperature within 90 minutes in load
condition and can retain temperature up to 6 hours in case of power loss.
Control Panel: Digital Temperature display with microprocessor-based
controller with additional temperature display & alarm indication with buzzer at
mortuary Chamber surface.
Suppy, Installation, Testing and Commisioning of 4 body mortuary cabinate of
approx. Force draft type PUF Panel: 80mm thick PUF panel with both side S.S -
304 grade sheet of 0.5 mm thickness & PUF density should be 40 kg/m3 Drawer
Tray: Made with high grade SS 304 box pipe. MS powder coated trolly
mechanism along with ancillary material SS Tray, Temperature: -8 C to +8 C,
Door: Overlap type door with heavy duty hinges & Handles with closer along
with push type gasket for easy operation Size: 32” X 32”, Lock SS: Individual lock
& Key for each door, Identification: Each Window should be facilitated for Body
Identification tag (replaceable),Vapor proof lights, Refrigeration System: Air
Cooled, Split Type and Capable to run at minimum 45 deg C Ambient with CFC Rupees Four Hundred
free refrigerant gas R407C/R404A for low maintenance. Compressor Type : Ninety Thousand Only
Hermetic reciprocating/scroll type compressor, Indoor Unit: SS tube & Copper
fins type Indoor Unit with SS casing capable to maintain low relative
humidity.Refrigerant Pipe IDU to ODU up to 5 mtr :SS/Copper inner grooved,
Power: 415 V, 3 Ph, 60 Hz, Temperature achievement and retention : Ref.
System should be able to achieve temperature within 90 minutes in load
condition and can retain temperature up to 6 hours in case of power loss.
Control Panel: Digital Temperature display with microprocessor-based
controller with additional temperature display & alarm indication with buzzer at
mortuary Chamber surface.
Suppy, Installation, Testing and Commisioning of 2 body mortuary cabinate of
approx. Force draft type PUF Panel: 80mm thick PUF panel with both side S.S -
304 grade sheet of 0.5 mm thickness & PUF density should be 40 kg/m3 Drawer
Tray: Made with high grade SS 304 box pipe. MS powder coated trolly
mechanism along with ancillary material SS Tray, Temperature: -8 C to +8 C,
Door: Overlap type door with heavy duty hinges & Handles with closer along
with push type gasket for easy operation Size: 32” X 32”, Lock SS: Individual lock
& Key for each door, Identification: Each Window should be facilitated for Body
Identification tag (replaceable),Vapor proof lights, Refrigeration System: Air
Cooled, Split Type and Capable to run at minimum 45 deg C Ambient with CFC Rupees Three Hundred
free refrigerant gas R407C/R404A for low maintenance. Compressor Type : Eighty Thousand Only
Hermetic reciprocating/scroll type compressor, Indoor Unit: SS tube & Copper
fins type Indoor Unit with SS casing capable to maintain low relative
humidity.Refrigerant Pipe IDU to ODU up to 5 mtr :SS/Copper inner grooved,
Power: 415 V, 3 Ph, 60 Hz, Temperature achievement and retention : Ref.
System should be able to achieve temperature within 90 minutes in load
condition and can retain temperature up to 6 hours in case of power loss.
Control Panel: Digital Temperature display with microprocessor-based
controller with additional temperature display & alarm indication with buzzer at
mortuary Chamber surface.
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv Rupees One Hundred
6 6 grade ISI marked copper wires of following size to be erected as directed. (j) 150 Mtr. 127.26 Twenty Seven and Twenty
4.00 Sq.mm 3 core round PVC sheathed Six Paisa Only
Rupees One Hundred
7 7 (k) 4.00Sq.mm 4 core round PVC sheathed 500 Mtr. 176.75 Seventy Six and Seventy
Five Paisa Only
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth continuity of following Rupees Four Hundred
8 8 type, erected on PVC / Metallic/Wooden box, single mounting base frame 53 Pt. 449.45 Forty Nine and Forty Five
covered with textured/metallic/white front plate modules erected on / in wall / Paisa Only
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed. (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete Cat. III
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS Rupees Eighty Two and
PVC insulated stranded wire of green colour for earth continuity of following Eighty Two Paisa Only
size (A) With medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq.
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
Watt assembled on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure die
cast powder coated and high U.V. & corrosion resistance with diffuser housed
in aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.95, THD < 15 %, Rupees One Thousand
CCT 3000 K to 6500K, Seven Hundred Ninety
Luminaire efficacy> 85 lumens/watt , Four and Seventy Seven
LED driver efficiency > 85 % Paisa Only
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.) (B) LED Panel Light
with provision for Plane front frame with translucent cover fixed to housing
complete.IP20 (vi) 36 watts, 24" x 24", Surge- 2KV Cat-lll
Providing and erecting Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating Rupees Sixteen Thousand
11 11 200A.with variable Thermal & magnetic release suitable to work on A.C.supply 1 Ea. 16221.61 Two Hundred Twenty One
50 c/s. with all internal connections, spreader tinned copper & complete and Sixty One Paisa Only
erected in existing 16 G.M.S.housing ICS=100% of ICU only Cat III
Rupees One Thousand Six
Note:-1 Add Rs. 10% extra for housing/Encloser of MCCB for above Item No
12 12 1 Ea. 1622.16 Hundred Twenty Two and
(The Enclosures should be used of same company of MCCBs to be used)
Sixteen Paisa Only
Providing and erecting busbar chamber confirming to IS-375 fabricated from
G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and
necessary busbar supports with COPPER busbar having current density not Rupees Five Thousand
more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped Seven Hundred Thirty One
with colour insulation tape for phase sequence, three phase & neutral each and Seventy Five Paisa
suitable for following current capacity with necessary painting mounted on wall Only
or pedestal frame of required size with necessary connections.(B) Suitable for
200 Amp. capacity
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable
Rupees One Hundred
to operate on 240 V A.C. system and having breaking capacity 10 KA to be
14 14 96 Ea. 112.11 Twelve and Eleven Paisa
erected in existing box. confirming to IS 8828/1996 with ISI Mark
Providing & erecting 240 V MCB double pole switch for motor & inductive load Rupees Two Hundred
15 15 (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box 4 Ea. 299.97 Ninety Nine and Ninety
having following capacity (A) 6 to 32 Amp. Cat.III Seven Paisa Only
Rupees Three Hundred
16 16 (B) 40 Amp. Cat.III 10 Ea. 330.27 Thirty and Twenty Seven
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Rupees Seven Hundred
17 17 Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box 14 Ea. 737.30 Thirty Seven and Thirty
having following capacity (c)63 Amp. Cat.III Paisa Only
Supplying & erecting 20 Amp 10 KA ‘C Curve’ single pole MCB with 20 Amp. Rupees Five Hundred
18 18 Plug socket, company fabricated powder coated sheet steel enclosure erected 1 Ea. 527.22 Twenty Seven and Twenty
as directed with connection. [A] Metal Clad Socket with metal clad top Cat.III Two Paisa Only
Plastic enclosure fitted with DIN rail suitable for incorporating One / Two nos. Rupees Fifty Two and Fifty
MCB Two Paisa Only
Rupees One Hundred
Sheets steel powder coated enclosure suitable for incorporating One/Two nos.
20 20 10 Ea. 176.75 Seventy Six and Seventy
Five Paisa Only
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail,
Rupees Three Thousand
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate
21 21 3 Ea. 3412.79 Four Hundred Twelve and
nos. of MCBs.(The DBs should be used of same company of MCB to be used)
Seventy Nine Paisa Only
suitable for (B) three phase incoming and single phase horizontal type outgoing
Per phase isolation type (PPI) (b) sheet steel double door (iii)8 way
Rupees Three Thousand
Eight Hundred Seventy
Four and Thirty Six Paisa
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Rupees Three Hundred
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in
23 23 200 Mtr. 378.75 Seventy Eight and Seventy
existing trench / pipe of following size of cables (D) 3 1/2 core 70 Sq. mm (
Five Paisa Only
Sq. mm 1/2 core)
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or
Rupees Seventy Four and
24 24 required depth for laying any size of cable or locating the fault all over the run 150 Mtr. 74.74
Seventy Four Paisa Only
and back filling the same and making the surface as normal ground.
Providing and, fixing heavy duty flange type brass double compression type
cable gland with rubber ring for PVC insulated armoured cable complete with Rupees One Hundred
out going tails, insulating tape etc for following size of cables. (C) 3 & 1/2 core Three and Two Paisa Only
Solder less crimping type Aluminium lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to Rupees Twenty Five and
switchgear terminals with brass/cadmium plated nut bolts in an approved Twenty Five Paisa Only
manner. (E) 70 Sq.mm.
Rupees Twenty and
Twenty Paisa Only
Total Amount (without GST) Rs.
Total Amount (without GST) Rs.
Dy. Executive Engineer (Ele.) Executive Engineer (Elec.)
PIU, Vadodara PIU, Vadodara
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
141 Tender Notice Electrical .pdf
Electrical Make List.pdf
PM Room Gotri Schedule B.pdf
PQ CRITERIA .pdf
SBD Book 2023 Final 17 01 2024.pdf
specifications_Mortuary.pdf
Standard Specification for Electrical Work.pdf
Download all tender documents and submit your bid