| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹24.1 L+₹41,963.42 (1.77%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹25.6 L+₹1.9 L (8.03%)Rejected-Finance | L3 | Rejected-Finance Third lowest |
Tender Value
Refer Docs
EMD Value
₹49,540
Closing Date
30 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Palampur
Holta Camp Palampur Kangra (H.P) 176061
PROVN OF 03 X TOILET BATHROOM AND GEYSER AT JCO LIVING AREA OF 5/4 GR AND CERTAIN OTHER SANCTIONED WORKS AT PALAMPUR MIL STN
2020_MES_375796_1
GEP- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹49,540
Yes
26 Nov 2020
8 Sept 2020
2 Oct 2020
8 Sept 2020
30 Sept 2020
16 Sept 2020
60 days
Amount
SCHEDULE 'A' PART-I ( B/R WORKS): Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, or for shafts, wells cesspits, pier holes, etc and not exceeding 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L hard core of broken stone or boulders of guage exc 63mm but not exc. 100mm, deposited, spread and levelled in layers, watered and rammed to a true surface, complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in mass concrete complete all as specified and directed.
M&L walling of random rubble, un-courses, well bonded bedded & solidly hearted built in cement mortar 1:6, complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6, complete all as specified and directed.
M&L pre-cast cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) as in landings, cover slabs for man holes and similar articles, set in CM 1:6 complete all as specified and directed.
Reinforced cement concrete, 1:2:4 ( Nominal Mix), type B-1(using 20mm graded crushed stone aggregates) ,beams, cantilevers, bressummers, lintels over 1.5m span and the like, complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild Steel TMT bars 5 mm dia and over upto 10mm dia in stirrups and binders etc including cutting, binding bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to TMT Bars complete all as specified and directed .
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and complete all as specified and directed.
S&F mild steel roof trusses (framed), trussed, purlins, crane gantries. rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe 410-W (Grade E-250) complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, compete all as specified and directed. (Colour as approved by GE)
M&L rendering 15mm thick plaster in cement mortar(1:4) on fair faces of brick work or concete surfaces, finished even and smooth without suing extra cement complete all as specified and directed.
M&L rendering 15mm thick plaster in cement mortar(1:6) on fair faces of brick work or concete surfaces, finished even and smooth without suing extra cement complete all as specified and directed.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25cm, complete all as specifed and as directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) 25mm thick as in sub base of flooring, leveling course of flooring or levelling course of roof etc, complete all as specified and directed.
M&L Non-skid, joint free (edge cut) coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L joint free (edge cut) coloured glazed ceramic tiles in vertical surfaces 300 x 450x 7mm/ 300 x 600 x 7mm as in skirting/dado etc, over and including 10mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete all as specified and directed.
S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, supplying and fixing in opening as per specifications & directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified & directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares n.exc. 0.50 sq.m in each pane, complete all as specified and directed.
Peparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted, complete all as specified and directed .
M&L prepartion of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including fixing fittings such as GI nipple for inlet, outlet, washout and overflow etc, including 20mm size ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed.
S&F vitreous China squatting pan orissa pattern size 580mm x 440mm white with integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and directed.
M&L 10 litres capacity PVC, low level, valveless, syphonic action type flushing cistern, inlet ball valve, float valve, handle and fixing arrangement, 32mm dia PVC flushing pipe and 15mm dia, 450mm long PVC connection with CP brass coupling nuts and PVC washer at both ends (fixed in repair), complete all as specified and directed.
S&F stop valve/angle valve, cast copper alloy, fancy type,chromium plated, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15 mm bore iron pipe or for union complete all as specified & directed.
S&F fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified & directed.
S&F GI tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors (concealed tubing) complete all as specified and directed. Note:- The cost for cutting chases in walls, floors, etc and their making good for concealed pipe work included in this item if required.
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors (concealed tubing) complete all as specified and directed. Note:- The cost for cutting chases in walls, floors, etc and their making good for concealed pipe work included in this item if required.
S&F PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors etc, 110mm bore of pipe, complete all as specified and directed.
S&F PVC (SWR) bends of any radius for 110mm bore pipe, complete all as specified and directed .
S&F PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors etc, 75 mm bore of pipe, complete all as specified and directed.
S&F PVC (SWR) bends of any radius for 75 mm bore pipe, complete all as specified and directed .
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed .
S&F 150mm long, aluminium handle, cast type, anodised, complete all as specified and directed.
S&F 150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
M&L 75 mm thick PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even & fair & filling the joints (6 mm wide) with mastic filling i.e one part of bitumen 85/25 or VG-30 and 3 parts of sand by weight complete all as specified & directed.
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer, complete all as specified and directed.
S&F brass chromium plated tubular towel rail, 20mm dia, D type 60 cm long , fixed to wall with CP brass screw and PVC rawl plugs, complete all as specified and directed.
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 (40mm graded crushed stone aggregate) as in sub base of floors/ paver block/ path etc finishing the surface even & fair without using extra cement complete all as specified and directed.
M&L 60 mm thick rubber moulded coloured machine pressed precast concrete interlocking paver block any shape and size (shape as approved bt GE) laid in path,porch,hard standing or flooring etc conforming to IS-15658-2006, M-35 grade over and including 25 mm thick layer of sand cushioning, complete all as specified and directed .
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
Rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair face of brick work , finished even and fair without using extra cement, complete all as specified and directed .
Excavation over area not exc 1.5 m deep & getting out in any type of soil all as specified and directed
Construction of septic tank for 10 users (Brick construction with sub class 'B' bricks using old size bricks), complete all as specified and shown on drawings No CEPZ/C-TD/013/13 sheet No 1/5 to 5/5 dated 11.09.2013
Construction of septic tank for 25 users (Brick construction with sub class 'B' bricks using old size bricks), complete all as specified and shown on drawings No CEPZ/C-TD/013/13 sheet No 1/5 to 5/5 dated 11.09.2013
Construction of soakage well 1.80m dia and 3.00m deep below (Brick construction with sub class 'B' bricks using old size bricks) inlet pipe level (depth from ground level to below the inlet pipe 45cm)complete all as specified and shown on drawings No CEPZ/C-TD/013/13 sheet No 1/5 to 5/5 dated 11.09.2013
Vitreous china, wash hand basin, (white) of size 550mm x 400mm including brass CP waste coupling 32mm size with long screwed shank and fly nuts, PVC medium grade 32mm dia waste pipe, chain and plug, porcelain stopper , PVC connection 15mm dia, 450mm long with brass CP nuts and washers at both ends, complete all as specified and directed.
S&F pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' & 'Cold' with long screwed shanks and fly nuts, screwed for 15 mm bore iron pipe complete all as specified & directed.
Vitreous china wash down water closet pan(English type), white (excluding flushing cistern and flushing pipe), including connection to trap and to flushing pipe, anti-syphonage pipe, etc, complete all as specified and directed.
Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and backing coat, and removing unserviceable materials,debris and rubbish to distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or cement concrete block walls etc including raking out joints, hacking for key, scrubbing down with water etc, and removal of rubbish off the premises and leave the work clear of any plastering complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
M&L Vitrified Ceramic tiles 10mm thick (square / rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified.
M&L Plain cement concrete, M-10 (Nominal mix) type C-2 (using 40 mm graded crushed stone aggregates) bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm bore SGSW pipe, complete all as specified and directed.
M&L 150 mm dia reinforced concrete pipes, class NP-3, laid and jointed with collars complete all as specified and directed.
Excavation over area exc 1.5 m deep but not exc 3.00 m deep & getting out in any type of soil all as specified and directed
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:3 mixed with water proofing admixture on fair faces of brick work or concrete surfaces finished the surface even and smooth without using extra cement, complete all as specified and directed. Note:- Water proofing admixture to be measured & paid for separately.
Reinforced cement concrete, 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under reamed piles and mass concrete etc, complete all as specified and directed .
Reinforced cement concrete, 1:2:4 type B-1, using 20mm graded crushed stone aggregates as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses etc, complete all as specified and directed .
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed.
Formwork to to faces of walls, retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, complete all as specified and directed.
Supply only liquid water proofing compound of approved quality, complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and paving's not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
Taking up or down old 110 mm bore PVC waste and vent pipes with fittings laid in trenches or fixed to wall including cleaning for refixing or removal from site, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Raised pointing in cement mortar 1:4 to random or polygonal rubble, uncoursed or brought upto courses including raking out joints/pointing to existing or new surfaces complete all as specified and as directed.
Mild steel bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required hooks (Stay), heavy, for large gate, hook and pintle hinges: large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, plain angle cleats square bar belded to angle frame and knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed .
SCHEDULE 'A' PART-II ( EXTERNAL WATER SUPPLY):- Excavation in trenches n exc 1.5mtr wide and n exc 1.5mtr in depth for foundation etc in any type of soil and getting out soil, complete all as specified and directed
Returning filling in (soil) incl spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed .
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed .
S&F steel water tubing, 20 mm bore dia, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed.
S & F gun-metal, globe or gate valves, heavy duty, with iron wheel head, screwed both ends (ISI marked) of 20mm dia complete all as specified & directed.
M & L for cutting of existing pipe GI pipe line of size 50 mm size (02 cuts) in position for making branch connection 20 mm dia for inserting of Tee complete including Tee of required size and other fitting such as sockets, nipples, unions etc complete including making threads in position for both side as per site requirement and making good disturbed surface of walls to match with existing surface complete all as specified and directed.
SCHEDULE 'A' PART-III ( INTERNAL ELECTRIFICATION):- Point wiring for one light point controlled by one way switch with cable of size 1.5sqmm copper conductor cable multi strand PVC insulated FRLS (unsheathed) concealed type, drawing in and including PVC conduit 25mm dia having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat of red oxide primer on internal and external surface including cover plate for required module for mounting switches, sockets, regulators etc controlled by one, one way switch, including 1.5sqmm PVC insulated copper conductor continuous earth wire complete all as specified and directed. Note - (i) wiring shall be done using colour code
All as per the description of serial item No 84 here-in-before but for one fan point/Exhaust fan controlled by one, one way switch and regulator complete all as specified and directed.
All as per the description of item No 84 above but for 5 pin switch socket outlet 5 Amp on same board with other switches, complete all as specified and directed.
All as per the description of serial item No 84 here-in-before but for 3 pin socket outlet 15 amp independent board with cable of size 2.5 sqmm in point wiring and 1.5 sqmm in continuous earth wire complete all as specified and directed.
S&F switch piano flush button, 5 Amps, 240 volts, complete single pole one way all as specified and directed.
S&F socket out let 2 in 1, 3 Pin 5 Amps flush type all as specified and directed.
S&F switch piano flush type single pole one way 15 amp complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed.
S&F LED bulk head luminaire IP-65 with LED bulb 10 W complete all as specified.
S&F batten holder with LED lamp 10 W complete all as specified.
S&F LED box type tube light fitting suitable for 1x20W 4 FT complete with LED tube rod, fixed complete to wall/ceiling and PVC round/square block (02 Nos) of suitable size etc provided complete with flexible pipe of suitable size complete all as specified and directed.
S&F MCB distribution board sheet steel powder coated SPN 4 way acrylic body double door IP-42 protection with 200 Amp rated busbar 240 Volt complete all as specified.
S&F MCB SPN 32 Amps 10 KA 230 volts 'C' series complete all as specified.
S&F MCB SPN 16 Amps 10 KA 230 volts 'C' series complete all as specified.
S&F MCB SP 6 to 32 Amps 10 KA 230 volts "C" series complete all as specified.
Supply and fixing of exhaust fan AC single phase 240 V of size 300 mm sweep metal body 1400 RPM and making hole in brick/stone wall if required at site and making good disturbed complete incl provn of flexible wire 3 core of size 23/.0076 from ceiling rose to exhaust fan all as specified and directed.
Supply and installation of electric storage water heater (vertical type geyser five star rating, 25 ltr capacity 240 V, AC single phase having stainless steel inner tank complete in all respect including air release valve etc incl grouting nut bolt of suitable size and lenght minimum 4" long as per site requirement and making necessary inlet/outlet water connection including suitable PVC pipe suitable for hot and cold water and making electrical with plug top 15 amps and water connection and making good disturbed surface of walls to match with existing surface complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/Polycarbonate, isolated body, complete all as specified and directed .
Sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, sinlge core, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected including taking down and making good disturbed surfaces of walls, floors etc to match with existing surface, complete all as specified and directed . (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
Earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, including testing on completion. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
SCHEDULE 'A' PART-IV(EXTERNAL ELECT SUPPLY):- Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Sand cushioning to underground cable provided with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable. The top layer of 15cm shall be punned to 10 cm (total 18 cm) complete all as specified and directed.
Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed.
Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified and directed.
M/S SAI ENGINEER
VIVEKA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .