Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC FIRST FLOOR 44 DDA SHOPPING COMPLEX BUDH BAZAR SIDE 42 KALKAJI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L1 | Accepted-AOC Work has been awarded due L1. | |
| 2 | L2₹38.6 L+₹75,450 (1.99%)Rejected-Finance | L2 | Rejected-Finance Due L2. | |
| 3 | Rejected-Technical C 736 GAUR GREEN AVENUE ABHHEYKHAND II INDIRAPURAM GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | UTTAR PRADESH | 201009 | - | Rejected-Technical 1. Not fulfilling all technical compliance. 2. Self-Certificates/ Test Reports(private laboratory) submitted are not satisfactorily. | |
| 4 | Rejected-Technical 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | - | Rejected-Technical 1. Not fulfilling qualifying criteria w.r.t. similar type of work completion. 2. Not fulfilling all technical compliance. 3. No Test Reports attached. |
Tender Value
Refer Docs
EMD Value
₹80,794
Closing Date
30 Oct 2020, 6:00 pmClosed
AIRPORT DIRECTOR
AIRPORTS AUTHORITY OF INDIA, CIVIL AERODROME,RAJKOT.
SITC for Integrated Surge Protection and Equipment bonding for CNS units at AAI, Civil Aerodrome, Rajkot
2020_AAI_59046_1
AAI/RAJ/CNS/SPD/2020-21
Open Tender
Miscellaneous Works
Item Rate
60 days
Rajkot Airport
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,680
AAI
₹80,794
3 Mar 2021
5 Oct 2020
2 Nov 2020
6 Oct 2020
30 Oct 2020
6 Oct 2020
6 Oct 2020 - 19 Oct 2020
Amount
Primary Surge Protection: Supply, Installation, testing and commissioning of 100 kA, 3 phase Surge Divertor with neutral protection using single block metal oxide varistor in pre-wired IP55 grade metal enclosure with voltage protection level < 1.5 KV shall be provided on the mains power entry point in compliance with IEC 61643/IEEE C62.41/ASNZ 1768/ANSI Standards complete with sensing circuit, potential free contacts, necessary indications and alarm for Essential / non essential Panel. To be connected in parallel at the essential / non essential panel of following locations: 1. Technical building 1st floor- 1 No. 2. S CCTV- Ground floor-1 No. 3. NDB - 1 No.
SECONDERY PROTECTION: Supply of Multi Stage Series Power Filter (MSSPF) 125 Amps 3 Phase, 4 wire with neutral protection and built in MOV based surge diverter of 40kA at Input and 40kA rating at load side prewired in IP55 grade Powder coated metal enclosure with 125Amps MCB, service change over switch, complete with sensing circuit, potential free contacts and necessary indicators and alarms connected in series with UPS input in following locations. 1. Automation for 4 nos. of 10 KVA UPS. 2. Equipment Room - 4 x 3KVA UPS. 3. VCCS Room- 2x3 KVA UPS. 4. DVR room - 2x3KVA UPS. 5. DATIS - 2x2KVA UPS.
SECONDERY PROTECTION: Supply of Multi Stage Series Power Filter (MSSPF) 63 Amps 3 Phase, 4 wire with neutral protection and built in MOV based surge diverter of 40kA at Input and 40kA rating at load side prewired in IP55 grade Powder coated metal enclosure with 63Amps MCB, service change over switch, complete with sensing circuit, potential free contacts and necessary indicators and alarms connected in series with 10 KVA x 2UPS input in following locations. 1. SCCTV for 2 Nos of 10 KVA UPS.
SECONDERY PROTECTION: Supply of Multi Stage Series Power Filter (MSSPF) 32 Amps 1 Phase, 2 wire with neutral protection and built in MOV based surge diverter of 40kA at Input and 25kA rating at load side prewired in IP55 grade Powder coated metal enclosure with 32Amps MCB, service change over switch, complete with sensing circuit, potential free contacts and necessary indicators and alarms connected in series with 2 KVA x 2 UPS input in following locations. 1. NDB- for 2 Nos of 2 KVA UPS.
EQUIPMENT LEVEL PROTECTION :- Supply of 120KA. Surge protection device against the protection from Noises, ESD, EPR and abnormal electrical characteristics which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V to be connected in parallel to the circuit, Confirming to CE, tested and certified as per latest certification (IEC- 61643-1, IEC-61000-4-5, IEC-61000-6-1, IEC61000-6-3) in Pre-wired metal enclosure with pulverulent body painting including all accessories. 1. Automation -2 Nos. 2. SCCTV - 1 No. 3. Equipment Room -2 Nos. 4. VCCS -1 No. 5. DVR - 1 No. 6. DATIS -1 No. 7. NDB - 1 No.
Supply of Earth Bonding water proof junction Box.
Supply of 35 Sq.mm copper flexible wire for earth bonding (ISI Marked). Purity > 95%.
Supply of 16 Sq.mm copper flexible wire for equipment bonding (ISI Marked). Purity > 95%.
Supply of 10 Sq.mm copper flexible wire for equipment bonding (ISI Marked). Purity > 95%.
Supply of 40mm or suitable dia B class GI Pipe for laying cable in surface.
Refurbishing of earthing at Technical building and NDB.
Supply, Installation, testing and commissioning with accessories for item No. 1 to 11.
Secom Services India Pvt.Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .