Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC H 45 MAHESH NAGAR AMBALA CANTT 133001 HARYANA | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹33.1 L+₹74,869.20 (2.31%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹34.0 L+₹1.6 L (4.90%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹34.1 L+₹1.7 L (5.28%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹35.9 L+₹3.5 L (10.9%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
14 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-61(P)/2020-21 PROVN OF CERTAIN SANCTIONED WORKS UNDER AGE B/R-I OF GE (NORTH) AMBALA CANTT
2020_MES_371142_1
GE(N)Amb-61(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹84,000
Yes
6 Jan 2021
16 Nov 2020
16 Dec 2020
16 Nov 2020
14 Dec 2020
30 Nov 2020
16 Nov 2020 - 30 Nov 2020
60 days
Amount
Schedule 'A' part-I ie B/R items
Surface excavation not exceeding 30cm deep and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavation over areas, n exc 1.5m deep and getting out in soft/loose soil, complete all as specified and as directed by the Engineer-in-Charge.
M & L loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits etc complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
M & L sand filling under floor or in foundation including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
Removing of excavated material to a distance not exc 50 m and depositing at a level not exc 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc 63mm , deposited , spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L factory made cement concrete kerb stone/PCC block of size 45 cm x 45 cm x 15 cm thick or as required at site made from PCC 1:1.5:3 type A1 using 20 mm graded crushed stone aggregate, hydraulically presed with plan fair faces, including chamfers, weathering, throating and jointed in cement mortor 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L providing cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, copings including necessary form works, weathering slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate in chajjas complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks except bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 using old servicable bricks including cleaning of bricks complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks in one brick thick straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 using 12.5 mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
M & L applying evenly a coat of blown type bitumen at the rate of 1.50 kg per sqm and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and as directed by the Engineer-in-Charge
M & L polythene film, 150 micron thick laid on and including a coat of bitumen primer @ 0.30 to 0.50 kg per sqm including cleaning of surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges, work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
Formwork to sides of pillars, posts,struts piers,columns and stanchions flat rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
M&L 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkets or frame of any description n.exc 1.5 sqm each complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkets or frame with shutters (without taking off shutters from the frames) of any description n.exc 1.5 sqm each complete all as specified and as directed by the Engineer-in-Charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing factory made uPVC white Sliding window area n.exc 2.00sqm, three track made of extruded profiles with wall thickness of 2.3mm (+/-0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh Sash (42mm x 57mm), Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2+/ -0.2mm thick galvanized steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. hardware: Touch Lock of zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.14mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.)
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, as roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminum alloy anodised sliding door bolt 250 mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of externded sections or cast aluminum alloy complete all as specified and as directed by the Engineer-in-Charge.
S & F butt hinges 100 mm long extruded aluminum alloy with galvanised mild steel hinge pin anodised type B-21 and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge
S&F Galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
S&F 1.25 mm thick mild steel plain black sheet in wall cladding, steel gates and similar work cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up mitred angles etc as required, complete all as specified and as directed by the Engineer-in-Charge.
M&L for TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L for mild steel TMT bars 6mm to 8mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates of Fe-410-W(Gde E-250) quality-B complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel work in verticle post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as specified and as directed by the Engineer-in-Charge.
S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick with AZ-150 coating of red colour having tensile strength 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick with AZ-150 coating of red colour having tensile strength 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
M & L 100mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L glazed ceramic coloured tile premium/1st quality in verticle surface such as skirting and dado of size 450x350x7-8 mm thick/350x250x7-8mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 10mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M & L rendering 15 mm thick on other than fair faces of brick wall or concrete surfaces in CM 1:6, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge
M & L rendering 15 mm thick on fair faces of brick work or concrete wall surfaces in cement mortar 1:4 and including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M & L tinted sheet glass 4.80mm thick and glazing with oil putty in square n exc 1.00 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
M & L preparation of new wooden surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new steel and iron surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F 500 litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge Note:- Tank shall be in white colour.
S & F bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm bore cast copper alloy chromium plated stop valves, fancy type with long shank and cup (concealed type), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 45 cm long with PTMT nuts at both ends complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls etc complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC(SWR) bends of any radius, for 110mm bore pipes, with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
M & L 75mm bore dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
M & L PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
M & L concrete bed in PCC 1:3:6 type C2 using 20 mm graded crushed stone aggregate to drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 100 mm dia (internal) PVC (SWR) pipes complete all as specified and as directed by the Engineer-in-Charge. (Pipes shall be measured & paid separately).
M & L cutting into existing manholes for connecting new drain, making good to pipe 100 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
Demolition of Cement concrete (un-reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position (framed work) complete all as specified and as directed by the Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type and any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
M & L 40 mm thcik plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in floor and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L rolled mild steel framed work as in door or gates of angle or other section with gusset plates, rails braces etc. complete, drilled for fixing for steel sheeting or other covering. Doors etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M & L APP based polymeric membrane minimum weight 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less 150 gms) laid on primed surfaces by forced application over and including bitumen primer 1.2 kg per sqm complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8, type D2 using 40mm graded crushed stone aggregate as in sub base of floor and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L Non skid coloured ceramic tiles premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 10mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L Non skid coloured ceramic tiles premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 10 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered surfaces of wall and applying two coats of oil emulsion distemper with painting roller over and including 3mm thick wall care putty in two or more coats to achieve smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new plastered/unplastered surfaces of concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of newly plastered/unplastered surfaces of brick/concrete wall and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of oil emulsion distemper with painting roller over and including 2 to 3 mm thick wall care putty in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge
S & F toilet paper holder of brass chromium plated fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed by the Engineer-in-Charge
S & F vitreous china squatting pan, Orissa pattern, of size 630 mm x 450 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, including cast iron 'S' trap 100 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
Supply and fixing grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed by Engineer-in-Charge.
M & L machine cut kota stone slab flooring 20 to 22 mm thick of size not less than 550mm x 550mm in floor set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab 20 to 22 mm thick of size not less than 550mm x 550mm in skirting/dado etc, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames exc 1.5 sqm but not exc 4 sqm each and removing from site complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by engineer in charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately.
M&L machine pressed rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 40 mm thick complete all as specified and as directed by the Engineer-in-Charge
S & F 605x605 mm aluminium powder coated snap grid frame work for false ceiling including fixing of arrangement including hanging. The snap grid shall be consist of aluminium main and cross tee of size 24mmx32mmx 0.30mm and 15mm x32mmx0.30mm respectively, the size of aluminium angle and cleats etc shall be as specified in SSR Part-I (2009). The snap grid frame shall fixed to ceiling with supporting hangers consisting of 4 mm dia GI wire with necessary bolts, nuts and washers including laying 4mm thick designer decorative type asbestos cement ceiling board ('E' Board) including two coats of acrylic emulsion paint over a coat of cement base primer complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded coloured (using red colour pigment or colour as approved by GE) precast concrete interlocking designer paver block (double glossy),any shape and size conforming to IS 15658-2006 of 80 mm thickness grade M-40 with grey cement and pigments over and including a layer of sand cushioning, 40 mm thick complete all as specified and as directed by the Engineer-in-Charge
S & F brass chromium plated Jet spray with flexible pipe complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing cascade type vitreous china wash down water closet pan of minimum size 690 x 370 x 680mm including flushing cistren vitreous china white (excluding fixing bolts and flush pipe) including plastic water closet seat white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device and brass chromium plated Jet spray with PVC pipe with all accessories complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china counter top wash hand basin white of minimum size 595mm x 420mm x 2000mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
S & F soap dish vitreous china white approximate size 160x160x90mm fixed to plug with chromium plated brass screw complete all as specified and as directed by the Engineer-in-Charge.
S & F WHB mixer brass chromium plated for mixing hot and cold water, screwed down for iron pipe 15mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks in one brick thick honey comb wall built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel work as in rungs of soakage well, bands, straps and similar small article works conforming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1:3 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting exc 20 cm girth complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting n.exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
M & L 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite and rounding of edges of granite over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L preparing new plastered surfaces of wall and applying two coats of exterior emulsion paint with painting roller over and including 3mm thick wall care putty in two or more coats to achieve smooth surfaces over a coat of primer complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' part-II ie E/M items
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete including fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls/floors/ceiling, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light point, tube light point, fan/exhaust fan, security light point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 3.02 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 3.02 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6 amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6/16 amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED tube light fitting 1x18/20 watt, box type, 4 feet, aluminium housing and integrated electric deiver with and including tube rod 18/20 watt,cool/ warm white, surface/ wall mounted industrial model and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, pin type, 12 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix retrofix LED Bulb, 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, 1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 25 mm bore medium grade of length 1.2 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB single pole, 240 volt, 6 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB single pole, 240 volt, 6 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB single pole and nutral 240 volt, 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing of SPN distribution board 4 way, double door, IP 43, as per IS 8623 including 100amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimble, complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanished steel strip or wire armoured heavy duty electric cable 10 sqmm cross sectional area, 2 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing XLPE insulated, screened, PVC bedded, galvanished steel strip or wire armoured heavy duty electric cable 25 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade including taking out old unservicable cable complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L sand cushoning under and above the cable for protecting the cable complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm centre to centre both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
M & L for earthing complete with Copper earth plate electrode 600 x 600 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to copper strip size 20x 3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth strip protected by 25mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed including taking down unserviceable earthing. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 50mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe 20 mm dia duly grooved to copper earth plate wire mesh,protection pipe for earth lead upto 7.50m long, charcoal or coke and salt in alternate layers complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular fan regulator, 2 module electronic step type (socket type) , 120 watt,230volts,50 Hz, AC supply suitable for celling fan any type/make/sweep complete all as specified and as directed by Engineer-in-Charge.
S&F in repair sheet metal enclosure for MCCB/MCB Vertical IP 43 & 54 type, 4 way , MCCB+12 module ,TPN, doubble door , powder coated complete alongwith 200 Amp rated Bus bar and including one No. MCCB,4 Pole,125 Amps as incomer and MCB's as out going of suitable size and making all type of connections with suitable size of gland for incommer cable complete , concealed on wall surface & making good the distrubed surfaces as per existing adjoining surface. Note: For electric connection of MCCB 4 POLE suitable rating thimble / lugs shall be used on cable ends. (2) Rate of MCCB , 4 POLE , 125 Amps shall be deemed to be including in quoted rate.
S&F in reapir over voltage release 230 V,single phase in one module suitable ( for 3Ph+N) complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades, removing all scales, dust etc from the body fan & blades, filling all cavaties with filler and applying two coats of white synthetic enamel paint by spray pump, reassembling fan, writing MES No/SM on fan body with thick synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Fixing only ceiling fan obtained vide item No. 3.36 above and connecting up including provision of flexible cable cable 23/.0076 from ceiling rose or connector to fan,mirror items such as rubber reel, pin etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair RCBO Rcd MCB double pole, confirming to IEC-60947-2, 40 Amps,4 module , 30 ma (HI immunity) sensitivity , 230 volts, 50 Hz with degree of protection IP 20, rated conditional short circuit ICC 10 KA complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair sheet metal enclosure for MCB DBs 12 way , 240 volts with 200 amps rated bus bar single pole and neutral with acrylic double door IP-43 fixed on wall duly grouted in solid block, including copper lugs/thimbles duly crimped for connection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm dia suspention GI wire, one twin core multi stranded conductor circular or flat of size 16 Sqm complete all as specified and as directed by Engineer-in-Charge.
singh traders
MAYANK ENTERPRISES
V K Constructive Builders
Swami Enterprises
Karishan Kumar goel
M/s B.S.Jain
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .