| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | L1 | Accepted-AOC Tender Committe Accepted |
Tender Value
₹14.8 L
EMD Value
₹22,300
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Development of Tourism near Break Water at Thangassery Kollam_Electrification of associated Building
2021_HED_458976_1
51/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
60 days
Kollam Thangassery
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,300
₹22,300
5 Apr 2022
7 Dec 2021
27 Dec 2021
7 Dec 2021
23 Dec 2021
7 Dec 2021
60 days
Amount
Fabricating, supplying, conveying, lifting and erecting double arm tubular post of overall height of 7m using 6m 80mm and 3.0m 50mm Heavy G.I. Pipe having ISI mark and of approved quality as per the drawing, erected on a RCC 1:2:4 foundation in 4 Nos well steining of 0.3m depth and 0.75 m dia. and a muffing of 0.60x0.60m with height 1.0 m. The post shall be erected on 4 numbers of 20mm dia GI foundation bolts of length 2.3m having 100mm long standard thread with a 12mm thick GI flange suitable for 80mm C class pipe at the bottom of the post and 80 D flange on the muffing with 4 nos of 20mm bolt holes and 3Nos of 20mm nuts per bolt. The bottom of the post shall be provided with suitable size stiffner pieces.The post is to be painted with two coats of best quality industrial epoxy paint over two coats of industrial epoxy primer . Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete.All GI pipe sections to be used for the fabrication of the post shall be of TATA/ZENITH/APOLLO make.All steel items shall be dip galvanised.
Supply of BIS approved LED Luminaire with system wattage of 35W, made up of pressure die cast Aluminium body and anti UV PC Protector with integrated lenses for increased pole spacing and uniform light distribution, IP66, IK 08, system efficacy of 110 lm/W, CCT 4000K, operating temp range up to 50 degree and designed for efficient thermal management, lumen maintenance L70@ 50000Hrs, Upward Light Output Ratio is 0% at zero degree inclination to avoid light pollution, suitable for side / vertical mounting up to 48mm diameter, Colour Rendering Index > 70, a driver efficiency > 85%, with internal surge protection of 4kV and Power factor > 0.95.Make: Keselec Cat Ref: Nice-R 35W NW LED or equivalent
Conveyance, installation, testing and commissioning of departmentally supplied flood light/ area light luminaire with lamp to a height upto 8m from ground level.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6sq. mm + 2 X 6 sq. mm earth wire
Supplying, fabricating , erecting and commissioning floor mounting, fully compartmentalised, dust and vermin proof cubicle MAIN panel board of size 1250 x 1450 x 250mm or nearest suitable size using 16 G CRCA MS sheet, painting two coats of best quality synthetic enamel paint over two coats of epoxy primer, having one vertical bus bar chamber, three vertical and one horizontal cable alley having front openable bolting type cover with cable entry provisions, bolted type cable glanding plate using 14 SWG CRCA MS sheet at the top and bottom. The panel should have 75x40x6mm MS channel provided at the bottom as support and comprising the following. Incomer:-63 A, AC 23-A, 4 pole on-load Change Over Switch in open Execution Incoming:- 63A, 25kA FP MCCB setted to 50A and rotory drive kit including BUC handle and shunt trip coil with auxiliary contact- 1No,Outgoings:- 40 A FP MCCB 25 KA setted to 32 A - 2Nos with rotary handle ,25 A TP MCCB 25 KA setted to 20A - 4Nos with rotary handle and 32 A two way disconnectable type neutral link suitably connected,,All switches and MCCB should be of panel mounting,Ics=100% Icu and conforming to IS:13947part III (L&T/SIEMENS/Legrand) .Busbar Chamber: Busbar chamber with 25X3mm Copper strips 4 Nos or equivalent size one each for phases and neutral fitted on epoxy insulator. Switch interconnections to be done with suitably rated Copper conductors insulated with PVC heat shrinkable sleeves. Interconnections with the incoming and is also to be carried out using 25x3mm PVC insulated Copper strips supported using epoxy insulators and outgoing with suitable rated copper conductor as required. Protection :- ELR with CBCT , 3 Phase 4 wire Under & Overvoltage relay,reverse phase sequence relay (Auto/ manual reset ,Trip time and Power on delay 1 - 10 sec) OV / UV - adjustable , Electronic on delay timer 1 - 10 sec for shunt coil - 1 No,Control contactor 2NO+2 NC ,DIN Rail Surge Protection Device (4+0) Class B & Class C/ Type 1 & Class 2 Tested as per IEC 61643 Part 11:2016 . Nominal voltage -230V 50/60Hz, MCOV of 275 V , Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 200KA (8/20µ sec), Voltage protection level <1.5 kV & Residual Voltage @ 5 kA(8/20) <0.8 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 438 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for : L & N to PE . Short- Circuit Current rating (Isccr) – 25 kA/50 Hz . Back up fuse required more than 160AgG/gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec . Make : Raycap / Erico / Weidmuller .Metering and Indication:- Panel surface mounting 96 Sq.mm LED Multi-function meter with three line display to read V,A,,kVA,kVAr,PF,KW and frequency of make Schnider or equivalent suitable for 415V,50Hz with RS485 port- 2 Nos, 60/5 A Tape wound CT 3 Nos , and 2A SP MCB C Curve (Cat B)-6Nos and a 63A two way disconnectable type neutral link inside the cubicle. The panel board should have hinged shutters for OLCOS/ MCCB cubicles and front openable bolted type busbar covers and it should be fabricated as per Kerala State Electrical Inspectorate's norms and only after obtaining approval from the departmental officers at site for the design. Panel internal earthing should be provided using 25x3 mm copper strip with two earthing points at bottom side. (Panel drawing attached with the schedule)
Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FPVN 0400 Transparent door( 8 + 12 way) VTPN poly carbonate distribution board , with provision for Isolator/RCCB as incomer ,125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's painted, inclusive of , tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
Supply and fixing IP 65 weather proof polycarbonate 9module 200*238*111 MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Supply and fixing IP 65 Thermoplastic circuit breaker boxes 3 row 36 module 295 x 583 x 129 mm MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 25A residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing 0.3 m , 20 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle).
Supply of 4 core 4.0 sq mm PVC insulated and PVC sheathed armoured copper Power cable
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 16 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4.0 core 25 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed submersible copper cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4C x 10 sq.mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required..4C x 16 sq.mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required..4C x 25 sq.mm (32mm)
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 4 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supplying and making end termination nickel plated single compression brass cable gland for 3 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 6 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 6 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing single pole blanking plate in the existing
Supply and fixing hensel make Polycarbonate Cable Junction Boxes IP66/69 weather proof for outdoor installation (with plain knockouts for cable entry 155*210*92 KF 1616 B or equivalentand accessories for Cable Junction Boxes such as Copper Terminal Set 4.0 sq.mm 5 Pole 1 No,Support for Terminal 1No , DIN rail for fixing MCB including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
Supply and installation of wall mounting cubicle type dust and vermin proof 600x300x214 mm, Hensel make hinged door polycarbonate Enclosure - IP65 outdoor enclosure with provision for fixing KSEB meter, cut out & Neutral link with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 3 Nos of 63A HRC fuse units with 40A HRC fuse link and 1No 63A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 16.0 sq.mm copper wire.
Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make CA43a , 360x270x205mm IP66,IK 10 Glass fibre reinforced polyester enclosure with base plate including supply and fixing 40A , 25kA FP MCCB, with rotary handle, 3 Nos phase indication lamp and 3 Nos 2A SP MCB including wiring using 2.5 sq.mm wire for control wiring .
Supply and installation of wall mounting cubicle type Hensel make Mi 9300 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid 450 x 300 x 170 mm , IP65 with base plate and sufficient holes for fixing KSEB meter, cut out & Neutral link and fixing 20A , 10kA SPN MCB, C curve .
Supply and providing 1 No 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the existing enclousure and giving necessary inter connection using 4sq.mm copper wire and holes are to be provided in the box for entry and exit of wire.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and fixing B class G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 50 mm dia nominal bore
Wiring for light point / fan point/ exhaust fan/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required(Group C)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4.0 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 X 6 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required. 1 or 2 Module plastic box
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required.3 Module plastic box
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required. 6 Module plastic box
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75mm)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ 11 Telephone jack
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. CAT 6 RJ 45 computer jack .
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ 45 frame
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Supplying suspended LED luminaire Philips SM 270 C LED 30S - 6500 PSU WH or equivalent
Supplying Philips or equivalent batten LED tube 600mm 10W etc complete.
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
Supplying 20 W LED Tube with box type fixtures Essential LED tube 1200 mm 20W 865 T8 API Philips or equivalent
Supply and fixing 7/9 W LED lamp OSRAM / Philips or equivalent
Supplying Keselec Schreder make Street light luminaire 20W LED, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 90 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K).
Supply and fixing brass batten / angle holder including connection etc as required
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan Crompton highspeed or equivalent excluding resistance type regulator
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing metal box of 150 mm X 150 mm X 60 mm deep size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Supplying and fixing extra conduit down rod of 1m length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings). 40 mm dia with clamps made from 20 x 3 mm MS flat
Supply of single phase , 230V ,90W,1400 rpm, 305 mm sweep heavy duty exhaust fan ( Almonard or equivalent) in metal frame Category B ,
Supplying metal shutters suitable for 305 mm sweep heavy duty exhaust fan
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and drawing UTP four pair CAT 6 LAN cable in the existing surface /recess steel/ PVC conduit. One run of cable
Supplying and drawing 2 pair 0.5 sq mm FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply of Cat 6,2 metre patch cord
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200 mm X 250 mm X 60 mm deep
Supply and fixing 230V ,7A, single pole contactor AC-3 duty with 1NO+1NC contactor for 1 HP motor
Supply and fixing KSEB approved make single phase kWh meter 5 - 30A accuracy class 1 base mountable with LCD display.
Supply and fixing panel surface mounting 96mm square 3 line LED type Multifuntion meter with V,I and frequency measurement(vif) socomec or equivalent suitable for 230 ac 50Hz
Supply and providing 12 mm thick & 1 m wide electrical grade chequered type rubber mat to withstand 15 KV dielectric strength conforming to IS 5429 / 1969.
Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose , pressure gauge and clamps including fixing it to wall as required.
Supplying IP66, IK 10 rated 100W NW flood light luminaire with body of aluminium extrusion having luminaire efficacy >= 120lumen/watt supplied with IP67 rated best in class LED driver. Preffered make:Keselec-K Flood 100W- NW
Supply and providing single line diagram duly framed,laminated and placed in a conspicuous location for clear vision
Supply, fabrication, conveyance and fixing 50 mm dia heavy duty C class with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
Supply and fixing SP MPCB Suitable for 1H.P DOL with suitable thermal release range
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_656891.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .