| 1 | L1₹25.7 LAccepted-AOC 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.1 L+₹3.7 L (14.1%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹30.3 L+₹4.0 L (15.0%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹32.2 L+₹5.9 L (22.4%)Rejected-Finance D NO 9 2 1 1 VUDA QUATERS PITHAPURAM COLONY VISAKHAPATNAM PIN 530 003 | VISAKHAPATANAM | ANDHRA PRADESH | 530003 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹34.8 L+₹8.5 L (32.2%)Rejected-Finance MIG 2B 65 VINAYAKA NAGAR VUDA COLONY VISAKHAPATNAM 530044 | VISAKHAPATANAM | ANDHRA PRADESH | 530044 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Utility-I)
Garrison Engineer Utility-I, Near Samudrika, Naval Base Post, Visakhapatnam-530014
REPAIR AND MAINTENANCE OF LT/HT ELECTRIC SUPPLY DISTRIBUTION SYSTEM, UG CABLES AND CONNECTED ITEMS IN MRS AND SAILORS MD ACCN , TS, ASR, ARSR SITE AREA AT DOLPHIN HILL AND OTHER MISC WORKS UNDER AGE E/M NO. I OF GE(U-I) VISAKHAPATNAM
2021_MES_493079_1
8379/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility-I, Visakhapatnam
Class D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹90,000
Yes
2 Feb 2022
7 Dec 2021
4 Jan 2022
7 Dec 2021
3 Jan 2022
21 Dec 2021
60 days
Amount
Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in hard / dense soil complete all as specified and directed.
Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m bove the starting point complete all as specified and directed.
M&L for sand cushioning / sand covering for underground cable protection complete all as specified. Note: Punned thickness shall only be measured and paid.
Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Laying only sub class 'B' bricks laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge. ( Note: Serviceable bricks obtained from taking down shall be reused )
M&L for GI pipe light grade of following sizes laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge . Make : Surya Roshni Ltd / Tata / Jindal steel / Prakash
40 mm bore
50mm bore
80mm bore
100 mm bore
Disconnection of electric connection from feeder pillar box, dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt etc complete including necessary wiring of fidder pillar box with copper conductor cable, replacement of MCCB etc , excavation & earth work complete all as directed by Engr -in Charge. Note :- Replaced unserviceable parts if any viz. MCCB, Bus bar,Lugs,Volt/Ammeter, wiring etc shall be measured and paid as supply only which shall be measured and paid sepertely under item No 9.
Suuply only following items Compatible for serail item No. 8 here in above
MCCB 3 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA
MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
Aluminium bus bar 400 Amp complete suitable for 3 phase 4 wire system of length 0.65 Mtr
Aluminium bus bar 315 Amp complete suitable for 3 phase 4 wire system length 0.65 Mtr.
Aluminium lugs of size 16 Sqmm to 25 sqmm
Aluminium lugs of size 35 Sqmm to 50 sqmm
Aluminium lugs of size 70 Sqmm to95 sqmm
Aluminium lugs of size 120 Sqmm
Aluminium lugs of size 150Sqmm
Aluminium lugs of size 185 Sqmm
Aluminium lugs of size 240 Sqmm
Aluminium lugs of size 300 Sqmm
Aluminium lugs of size 400 Sqmm
Aluminium lugs of size 630 Sqmm
Aluminium bus bar 800 Amp complete suitable for 3 phase 4 wire system of length 1 Mtr
Aluminium bus bar 1000 Amp complete suitable for 3 phase 4 wire system of length 1 Mtr
LED phase Indicator lamp assy RYB
Wiring with single core 1100 Volts grade PVC insulated copper conductor cable of suitable size from bus bar to out going .
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed.
Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric cable of size 4 core 16 sq mm , 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
All as per item No 11 above but size 25 Sq mm 3.5 Core.
All as per item No 11 above but size 35 Sq mm 3.5 Core.
All as per item No 11 above but size 50 Sq mm 3.5 Core.
All as per item No 11 above but size 70 Sq mm 3.5 Core.
All as per item No 11 above but size 95 Sq mm 3.5 Core.
All as per item No 11 above but size 120 Sq mm 3.5 Core.
All as per item No 11 above but size 185 Sq mm 3.5 Core.
All as per item No 11 above but size 240 Sq mm 3.5 Core.
All as per item No 12above but size 400 Sq mm 3.5 Core.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade and including taking out cable from faulty portion in any situation/position complete all as directed for the following sizes :- Make: 3M / Denson / M-Seal / Raychem
3.5 core 120 sqmm to 150 sq mm
3.5 core 185 sqmm
3.5 core 240 /300sqmm
M&L for Earthing complete with glavanised iron or steel earth plate electrod 60 cm x 60 cms x 6.0mm thick burried directly in ground surrounded by charcoal or coke and salt (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate at a depth of not less than 1.5 metre below ground level connected to GI or steel earth wire 4mm dia by means of nuts, bolts, check nuts & washers, protected by GI pipe 15mm bore (light grade) and connected to maint switch board or main control board complete all as specified and indicated in electrical plate No 5 of SSR-1991 Part-I including testing on completion.
Dismantling rusted/defective LT panel doors/canopy / angle iron supports of any size and M&L for new LT panel doors of size all as per existing with 2 mm / 3.15 mm thickness MS sheet, hinges, locking arrangement, angle iron supports of any size etc complete including replacement of neoprene gasket and painting with a coat of of red oxide primer complete all as directed by Engr-in-Charge
M&L for 2mm thick fibre reinforced plastic coating with epoxy paint coat of approved color on the surface of panel board, RMUs after cleaning the surfaces thoroughly all as directed & specified.
M&L for Panting of LT Panels and fedder pillar boxes with epoxy paint coat of approved color on the surface of panel board, feeder pillar boxes,RMUs after cleaning the surfaces thoroughly by using spray gun all as directed & specified.
Dismantling Existing earthing and providing new maintenance free Chemical earthing complete with 40mm x 3000 mm Advance Chemical Earthing Pipe with (Strip in Pipe Technology) with 50 Kgs of Back Fill Compound buried directly in ground (Rocky soil) with earth pit not less than 2.5 M deep below the normal ground level with top edge of plate not less than1.5 M below normal GL connected to copper strip 25x6 mm as earth strip by means of SS bolts,nuts,check nuts and washers all as per IS 3043-1987 all as specified or indicated including testing on completion and as directed. The earth resistance shall be measured using fall of potential method as per para 37 of IS:3043 & Combined resistance should be less than 1 Ohms.Test results shall be submitted duly signed by all concern. (Note:-The unit rate shall be deemed to include for Excavation & earth work in any type of soil, PCC (1:3:6) type Chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8mm dia CTD bars@75mm c/c both ways , MS handle 12mm dia and funnel.
Construction of ring earth by providing multiple earth pits i) Wherever it is not possible to achieve required earth resistance with one earth electrode/pit due to difficult/rocky soil conditions, provision of ring earth consisting of more than one earth pit shall be done. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. ii) The distance between two successive earth electrodes shall be min. 3mtrs / length of electrode which ever is higher. and max. up to twice the length of the earth electrode. iii) These earth pits shall then be inter linked using 25X6 mm GI strip to form a loop preferably using exothermic welding or with the help of at least two number of stainless steel nut bolts of appropriate size. iv) The interconnecting strip shall be buried no less than 600mm (0.6m) below the ground level. This interconnecting strip shall also be covered with earth enhancing compound.
Cutting the tarmac / hard standings and excavating in trenches across the road with a size not exceeding 0.45 m wide and 0.6 m depth for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and as directed.
Boring of holes underneath road / foot path / hardstanding / culvert etc by using trencless technology by ultra sound technic and necessary machinery including providing 100 mm dia GI pipe medium grade for drawing cables complete all as specified and directed. Note: Length of GI shall only be measured and paid and necessary extra length which is required to bore shall be included in reate quoted.
Supply, lay, connect, test and commission multi core copper conductor cable of size 3 core 6 sqmm , PVC insulated LT 1100 volts grade GI strip/wire armoured in ducts/on structures including clamps, terminations on both ends with glands and connecting up to the equipment all as specified and directed:-
Material and labour for provision of earth mat laid in trenches/ ducts/ walls/ Roof Top made with GI strip of size 25 X 6mm including jointing by means of riveting and brazing complete all as required and directed.
Material and labour for provision of earth mat laid in trenches /ducts /walls/Roof Top made with Copper strip of size 25 X 6mm including jointing by means of riveting and brazing complete all as required and directed.
Supply , install ,Testing , Commissioming of Numerical feeder protection relay 50/51N (Earth over current), 67P (3Ph directional over current), 67N (Earth fault directional over current), 51V (Voltage controlled over current), 37 (3Ph under current),46 (Negative Phase sequence over current),59N (Residual over voltage),32 (Directional power protection under/over active/Reactive power),81 (Under over over Frequency ), 49 (Thermal Overload),79 (Auto resue),50BF (Circuit breaker failure direction),Cold pickup,Inrush blocking including taking down old relay complete all as specified and directed by Engr-in Charge.Relay will be on Modbus Protocol. (Make:- Schneider of Model Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 or its equivalent in ABB/SEIMENS)
Supply and fixing High Speed Master Trip Relay
Supply and fixing the following for METERING:
Supply and fixing the INDICATION LAMPS for C.B. ON/OFF/TRIP/Trip Circuit Healthy and Unhealthy/Spring Charged
Supply and fixing the following for CONTROL SWITCHES & Control Wiring
T‐N‐C Switch (Breaker Control Switch)
Trip Circuit Healthy Push Button
Control wiring with appropriate colours
Local Remote switch
Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one complete all as specified and directed.
Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one all as specified and directed.
Supply and fix incl dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 2500 Amps all as specified and directed.
Supply and fix including dismantling taking out unserviceable Breaker Nylon Wheel, For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Release Lever (Nylon ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
M&L for replacement of damaged space heater, 230V AC supply , 100 watt inside 11 KV HT VCB cable chamber including necessary connection, testing complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable HRC Fuse-Pt HT Side (VTF-11, 3A) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Control Circuit HRC Fuse : 2 A , 4 A , 6 A , 1 0A complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Service/Test Position Limit Switch 1NO+1NC For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
S&F multifunctional meter with LED display, accuracy class-1, e- navigator, including dismantling taking down unserviceable one and connection, programming, testing complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Isolating Contact For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed.
Supply and fix single (Red-Blue) phase bus bar spout suitable for 800 Amps to 1250 Amps VCB . .
Supply and fix single (Y) phase bus bar suitable spout for 800 Amps to 1250 Amps VCB . complete all as specified and directed.
Supply and fix Drive Beam suitable for 11 KV VCB 800 to 2000 Amps.complete all as specified and directed.
Supply and fix Epoxy Body suitable for 11 KV VCB up to 1250 Amps. complete all as specified and directed.
Supply and fix Dive Rod assembly with contact block VG2 suitable for 11 KV VCB up to 1250 Amps. complete all as specified and directed.
Supply and fix CT Spout suitable for VCB 800 to 2500 Amps 25 Ka chamber insulating bus support epoxy insulator of dia 95mm and 125mm length complete all as specified and directed.
MONITOR ENGINEERING WORKS
SAMPATH ENTERPRISES
ALPHA ENGINEERING CONSTRUCTIONS
jyothi constructions
DELTA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .