CA NO CWE/AMB/UTILITY-71 OF 2026-27 PROVN OF VARIABLE REFRIGERANT FLOW (VRF) AIR CONDITIONING SYSTEM IN WESTERN COMMAND SHOOTING NODE AT AMBALA CANTT (SPL WK) UNDER GE (UTILITY) AMBALA CANTT
2026_MES_792133_1
CWE/AMB/UTILITY-71 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Ambala Cantt
As per tender documents
9 documents required · 9 mandatory
₹500
GE (UTILITY) AMBALA CANTT
₹86,000
Yes
1 Oct 2026
1 Oct 2026
23 Oct 2026
1 Oct 2026
21 Oct 2026
16 Oct 2026
1 Oct 2026 - 8 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SCHEDULE 'A' PART-I (AIR CONDITIONING)
Design, supply, Installation, testing and commissioning of variable Refrigerant flow type multi unit air conditioning system suitable for year round air-conditioning to maintain inside conditions DBT 22+3º and RH (50+10%) and outside conditions of Ambala Cantt as per IMD record. The unit shall be of heat pump type, air cooled, factory fabricated and factory assemble and shall be capable of providing both cooling/ heating complete with indoor and outdoor units etc as per specifications given below:- | 2 | EACH JOB | - | - |
| 1.01 | Design, supply, installation, Testing and Commissioning of variable Refrigerant Flow air cooled Outdoor units of Minimum capacity 24 HP suitable for cooling and heating system suitable for year round air conditioning of temp bldg with Asbestos roof and ceiling at Shooting Node of size length 36.77 RM, Width-11.04 RM & Height-3.63 RM as scope given under to maintain inside temp DBT 22+3º and RH (50 + 10%) and occupancy strength 60 to 70, Lighting Load 5.20 KW & eqpt load 6.50 KW and outside condition of Ambala Cantt as per IMD record. having all hermetically sealed inverter type Scroll/ Twin rotary Compressor(s) with advanced EVI Compressor Technology, PCB with IP55 Protection, microprocessor based controller, Side/Top discharge type condensing units with R410 A refrigerant, vibration isolators with suitable foundation etc complete as required. Each Outdoor unit whether used individually or in module should have a double compressor. The unit shall deliver the rated capacity at 43 Deg C conditions and work even at 56 Deg C ambient temperature without tripping. The unit shall be suitable to work on 400 V+/-10% 3 phase, 50 Hz AC power supply. The Outdoor units shall have a minimum COP of 3.1 at 100% loading in cooling mode & ISEER of 6.5 at ARI/AHRI Conditions complete all as specified as directed. | - | - | - | - |
| 2 | Supply Installation Testing and Commissioning of following minimum capacity of 8.0TR High Static VRV/VRF Packged Floor Mounted Type Indoor floor mounted unit with complete support on the floor etc equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet, drain pump grill, necessary supports, vibration isolation,Cordless remote control etc suitable for operation on 230 V +- 10% 50 Hz AC supply complete all as specified as directed. | 4 | EACH | - | - |
| 3 | Supply Installation Testing and Commissioning of following minimum capacity of 5.0TR High Static VRV/VRF Packged Floor Mounted Type Indoor floor mounted unit with complete support on the floor etc equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve ,outer cabinet, drain pump grill, necessary supports, vibration isolation,Cordless remote control etc suitable for operation on 230 V +- 10% 50 Hz AC supply complete all as specified as directed. | 2 | EACH | - | - |
| 4 | Supply, fixing and commissioning of Y Joint/ refrigerant joint / Branch distibutors between Outdoors with nitrile rubber insulation, supporting etc. ccomplete all as specified as directed. | 2 | EACH SET | - | - |
| 5 | Supply, fixing and commissioning of refrigerant joint / Branch distibutors between Indoors with nitrile rubber insulation, supporting etc.complete all as specified as directed. | 4 | EACH SET | - | - |
| 6Supply installation Testing and Commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for F/VRV system, complete with fittings, with suitable adjustable ring type hanger supports, ng/brazing including accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories complete all as specified as directed. | |||||
| 6.01 | 9.5 mm dia (OD) (soft drawn) with appropriate tube thickness with 13mm thick insulation complete all as specified as directed. | 35 | RUNNING METRE | - | - |
| 6.02 | 12.7 mm dia (OD) (soft drawn) with appropriate tube thickness with 13mm thick insulation complete all as specified as directed. | 18 | RUNNING METRE | 100 | ₹1,800 |
| 6.03 | 15.86 mm dia (OD) (soft drawn) with appropriate tube thickness with 13mm thick insulation complete all as specified as directed. | 62 | RUNNING METRE | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
TenderU71.pdf
Tender Documents • 0.48 MB
BOQ_888171.xls
BOQ • 3.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .