Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.8 LAdmitted-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | L1 | Admitted-Finance | |
| 2 | L2₹69.7 L+₹1.9 L (2.76%)Admitted-Finance B 2 46 SECTOR 18 ROHINI DELHI 110089 | NORTH WEST | DELHI | 110089 | L2 | Admitted-Finance | |
| 3 | L3₹72.7 L+₹4.9 L (7.16%)Admitted-Finance E 2 216 GROUND FLOOR SHIV RAM PARK NEAR LUCKY GARDEN NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Doesnot meet the NIT criteria |
| Sl No | Description | Qty | Unit | Aircon Technique Pvt Ltd L2 | Supertech Engineers L3 | Sterling and Wilson Pvt Ltd L1 |
|---|---|---|---|---|---|---|
| 1.10 | Annual Operation & Maintenance cost of HVAC system inclusive the annual maintenance contract of the inventory of NABI (Comprehensive or Non comprehensive mentioned against each item)and listed as per the scope of work defined in Schedule-A of Volume-1 of tender document. | 12 | Month | 53,12,532 ₹53,12,532 | 39,60,000 ₹39,60,000 Lowest | 43,65,696 ₹43,65,696 |
| 1.20 | Annual Operation & Maintenance cost of HVAC system inclusive the annual maintenance contract of the inventory of CIAB (Comprehensive or Non comprehensive mentioned against each item) and as listed as per the scope of work defined in Schedule-A of Volume-1 of tender document. | 12 | Month | 15,93,756 ₹15,93,756 Lowest | 27,72,000 ₹27,72,000 | 22,49,664 ₹22,49,664 |
| 1.30 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
500mm dia | 14 | Nos | 7,000 ₹7,000 Lowest | 21,000 ₹21,000 | 14,000 ₹14,000 |
| 1.40 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
450mm dia | 14 | Sq Mtr | 6,300 ₹6,300 Lowest | 21,000 ₹21,000 | 14,000 ₹14,000 |
| 1.50 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
300mm dia | 14 | Nos | 4,200 ₹4,200 Lowest | 21,000 ₹21,000 | 14,000 ₹14,000 |
| 1.60 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
250mm dia | 14 | Nos | 3,500 ₹3,500 Lowest | 21,000 ₹21,000 | 14,000 ₹14,000 |
| 1.70 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
200mm dia | 10 | Nos | 2,000 ₹2,000 Lowest | 15,000 ₹15,000 | 8,000 ₹8,000 |
| 1.80 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
150mm dia | 14 | Nos | 2,100 ₹2,100 Lowest | 21,000 ₹21,000 | 11,200 ₹11,200 |
| 1.90 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
125mm dia | 14 | Nos | 1,750 ₹1,750 Lowest | 21,000 ₹21,000 | 9,800 ₹9,800 |
| 2.00 | Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes
100mm dia | 10 | Nos | 1,000 ₹1,000 Lowest | 15,000 ₹15,000 | 5,000 ₹5,000 |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
20 Oct 2023, 3:00 pmClosed
Adminstrative Officer
CIAB Sector 81 Mohali
Annual Operation and Maintenance contract for the Heating, Ventilation, and Air-conditioning (HVAC)
2023_DBTEC_774076_1
CIAB/7(73)/2023-24-Works
Open Tender
Electrical Works
Item Rate
365 days
Mohali
Please refer Tender documents.
2 documents required · 2 mandatory
₹1
Yes
CIAB
₹1.9 L
Yes
16 Nov 2023
29 Sept 2023
23 Oct 2023
29 Sept 2023
20 Oct 2023
29 Sept 2023
Annual Operation & Maintenance cost of HVAC system inclusive the annual maintenance contract of the inventory of NABI (Comprehensive or Non comprehensive mentioned against each item)and listed as per the scope of work defined in Schedule-A of Volume-1 of tender document.
Annual Operation & Maintenance cost of HVAC system inclusive the annual maintenance contract of the inventory of CIAB (Comprehensive or Non comprehensive mentioned against each item) and as listed as per the scope of work defined in Schedule-A of Volume-1 of tender document.
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 500mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 450mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 300mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 250mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 200mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 150mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 125mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 100mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 80mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 65mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 50mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 40mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 32mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 25mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 20mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) Pipes, cables etc, not exceeding 80 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre)
Aircon Technique Pvt Ltd
Supertech Engineers
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .