Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹6.9 L+₹1,205 (0.18%)Rejected-Finance | L2 | Rejected-Finance Second lowest |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
4 Feb 2021, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P) 176061
REPAIR/MAINTENANCE OF SOLAR WATER HEATER AND GEYSER AND REPLACEMENT ALL CONNECTED ITEMS MCBs DBs SUB MAIN WIRING IN OTM AND MD ACCN AT PALAMPUR MIL STN
2021_MES_412182_1
GEP- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Palampur
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹19,000
Yes
26 Mar 2021
13 Jan 2021
6 Feb 2021
13 Jan 2021
4 Feb 2021
21 Jan 2021
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
Taking down sub main wiring any type and any capacity with casing caping /concealed conduit/batten conduit complete all as directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS-H cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty PVC casing and caping with accessories, ISI marked with mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly and making good the disturbed surfaces to match with existingsurfaces .(i)One light point controlled by one, one way switch 5Amps complete all as specified and directed.
-Ditto- all as per serial item No 4.00 above but for fan point/Exhaust fan point controlled by one,one way switch 5/6Amps.
-Ditto- all as per serial item No 4.00 above but for 5/6 Amps socket point on independent board.
-Ditto- all as per serial item No 4.00 above but for 5/6 Amps socket point on same board.
All as per serial Item No. 4.00 above but for 15 Amps socket point on independent board with 2.50 Sqmm PVC insulated FRLS-H multi-stranded copper conductor with 1.50 Sqmm PVC insulated FRLS-H multi-stranded copper conductor as earth wire complete all as specified and directed.
S&F switch piano 5/6 Amp flush type single pole one way, ISI marked with valid CML No, complete all as specified and directed.
S&F socket outlets 5/6 Amps 2-in-1, 3 pin , flush type,ISI Marked with valid CML No, complete all as specified and directed.
S&F switch piano 15 Amp flush type single pole one way, ISI marked with valid CML No, complete all as specified and directed.
S&F socket outlets 2 in 1, 5/15 amps, flush type,ISI Marked with valid CMLNo, complete all as specified and directed.
Supply and fix steped type electronic fan regulator flush type on the existing phenolic laminated sheet as required complete all as specified and directed by engineer in charge.
S&F Ceiling rose, three terminals ISI Marked, surface bakelite,complete all as specified and directed.
S&F1x20W LED tube light fitting box type 4 feet long (2700/6500K as per requirement) complete with LED tube rod,fixed to wall/ceiling with PVC round/square block(02 Nos) of suitable size including connection complete all as specified and directed. (CG cat part No:DMLN1LT8-16 with tube cat part No LT8-20-865-2 or equivalent make as approved by GE)
S&F1x10W LED tube light fitting integral sleek extruded polycarbonate channel 2 feet long (2700/6500K as per requirement) with white acrylic cover batton integrated,fixed to wall/ceiling with PVC round/square block(02 Nos) of suitable size including connection complete all as specified and directed. (Bajaj cat part No:BCLSB10WH or equivalent make as approved by GE)
S&F in repairs,Lamp holder insolated body with back plate suitable for batten fitting complete all as specified and directed.
M&L Wiring for circuit / submain wiring in PVC casing caping along with 4.00Sqmm earth wire with 2 x 6.00 Sqmm FRLS-H PVC insulated unsheathed 1100 volts grade multi-stranded copper conductor, single core cable complete all as specified and directed.
S&F Factory made DB SPN 12 way double door,240 Volt with 200 Amps rated bus bar concealed in wall IP42/ 43 protection for fixing MCB complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA 40 amps including necessary connection complete all as specified and directed.
S&F MCB SP ‘C’ curve, 10KA 6 to 32 amps including necessary connection complete all as specified and directed.
Disconnecting & opening of solar water heater storage type of 100 capacity, desclaing with chemical and pressure pump, change the un-serviceable parts, re-assembling the same,testing complete all as specified and directed. Note:- All defective or unserviceable spare parts change during serviceing shall be measure and paid saperately as supply only
Disconnecting & opening of solar water heater storage type of 200 capacity, desclaing with chemical and pressure pump, change the un-serviceable parts, re-assembling the same,testing complete all as specified and directed. Note:- All defective or unserviceable spare parts change during serviceing shall be measure and paid saperately as supply only
S&F tuffen glass of heat collector for solar water heater 100 litre capacity including taking out old un-serviceable or brocken glass complete all as specified and directed.
Supply only tuffen glass of heat collector for solar water heater 100 litre capacity complete all as specified and directed.
S&F tuffen glass of heat collector for solar water heater 200 litre capacity including taking out old un-serviceable or brocken glass complete all as specified and directed.
Supply only tuffen glass of heat collector for solar water heater 200 litre capacity complete all as specified and directed.
Supply only rubber flange of 25mm dia with nut, bolt and washer for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement rubber flange of 25mm dia with nut, bolt and washer for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only brass flange of 25mm dia with nut, bolt and washer for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement brass flange of 25mm dia with nut, bolt and washer for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only copper pipe of existing size and length for collector of solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement copper pipe of existing size and length for collector of solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only nitrate insulation sleeve for solar water heater as per site requirement of 100/200 litre capacity complete all as specified and directed.
S&F in replacement nitrate insulation sleeve for solar water heater as per site requirement of 100/200 litre capacity complete all as specified and directed.
Supply only PVC insulation tape and alluminium filing tape for one solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F PVC insulation tape and alluminium filing tape for one solar water heater including taking down old unserviceable insulation tape and aluminium filing tape for one solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only heating element 3 Kw of existing make for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement heating element 3 Kw of existing make for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only thermostat 0 to 80 degree 11'' long of existing make for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement thermostat 0 to 80 degree 11'' long of existing make for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only heat exchanger of existing size and make for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of heat exchanger of existing size and make for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only rubber hose pipe of existing size, length and make for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of rubber hose pipe of existing size, length and make for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only flange gasket (as per sample) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of flange gasket (as per sample) for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only heat collector strip (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of heat collector strip (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only tank mixture valve (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of tank mixture valve (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
M&L soldering to copper pipe to rectify the leakage in solar water heater complete all as specified and directed.
Supply only heat exchanger (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of heat exchanger (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
Supply only tubing collector (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F in replacement of tubing collector (as per existing make and size) for solar water heater of 100/200 litre capacity complete all as specified and directed.
S&F cover sheet for protection of hot water tank for solar water heater of 100 litres capacity including taking down old un-serviceable cover sheet complete all as specified and directed.(as per existng size and make)
Supply only cover sheet for protection of hot water tank for solar water heater of 100 litres capacity complete all as specified and directed.(as per existng size and make)
Supply only cover sheet for protection of hot water tank for solar water heater of 200 litres capacity complete all as specified and directed.(as per existng size and make)
S&F cover sheet for protection of hot water tank for solar water heater of 200 litres capacity including taking down old un-serviceable cover sheet complete all as specified and directed.(as per existng size and make)
S&F in replacement 3 pin plug top of capacity 5 Amp AC 240 Volts 50 Hz complete all as specified and directed.
S&F in replacement 3 pin plug top of capacity 15 Amp AC 240 Volts 50 Hz complete all as specified and directed.
S&F in replacement 1.50 Kw heating element for electric storage type geyser including connection and testing complete all as specified and directed.
S&F in replacement 2.0 Kw heating element for electric storage type geyser including connection and testing complete all as specified and directed.
S&F in replacement 450mm long stainless steel flexible water connection pipe for electric storage type geyser including leakage testing complete all as specified and directed.
S&F in replacement thermostate for electric storage type geyser including connection and testing complete all as specified and directed.
S&F in replacement siphon assembly for electric storage type geyser including connection and testing complete all as specified and directed. (As per existing holes)
S&F in replacement copper geyser tank 25 litre capacity for electric storage type geyser including leakage testing complete all as specified and directed.
S&F in replacement copper geyser tank 50 litre capacity for electric storage type geyser including leakage testing complete all as specified and directed.
S&F in replacement glass wool for electric geyser storage type complete all as specified and directed.
S&F in replacement pressure release valve for electric geyser storage type complete all as specified and directed.
S&F in replacement safety valve for electric geyser storage type complete all as specified and directed.
S&F in replacement rubber gasket for electric geyser storage type complete all as specified and directed.
S&F in replacement PVC sheathed three core copper conductor flexible wire of size 40/0.0076 complete all as specified and directed
S&F in replacement sheet metal enclosures two pin and earth plug and socket complete with one single pole MCB 20 Amps C type 240 Volts complete all as specified and directed.
S&F in replacement outer body of electric geyser storage type 25 litre capacity duly white painted complete all as specified and directed.
S&F in replacement outer body of electric geyser storage type 50 litre capacity duly white painted complete all as specified and directed.
Taking down old unserviceable swing wall fan any type/size, supply and fixing of swing wall fan AC single phase 240 V of size 300 mm sweep complete with connection from ceiling rose to wall fan complete all as specified. Note -Old unserviceable wall fan to be deposited in MES store yard.
Taking down old unserviceable exhaust fan (PVC body) any type/size, supply and fixing of exhaust fan AC single phase 240 V of size 250 mm sweep 1400 RPM with louvers shutter and making good disturbed complete with connection from ceiling rose to exhaust fan all as specified. Note - Old unserviceable exhaust fan to be deposited in MES store yard.
Taking down old unserviceable exhaust fan (PVC body) any type/size, supply and fixing of exhaust fan AC single phase 240 V of size 200 mm sweep 1400 RPM with louvers shutter and making good disturbed complete with connection from ceiling rose to exhaust fan all as specified. Note - Old unserviceable exhaust fan to be deposited in MES store yard.
Taking down old unserviceable electric storage water heater any type/size, supply and installation of electric storage water heater (vertical type geyser minimum 5 star rating, 50 ltr capacity 240 V, AC single phase having stainless steel inner tank incl heavy duty pin type fasteners 4" long and PVC flexible connection pipe as per site requirement incl plug in top 15 amp and making necessary inlet/outlet water connection and making good disturbed surface of walls to match with existing surface complete all as specified. Note-old unserviceable electric water heater to be deposited in MES store yard.
Taking down old unserviceable electric storage water heater any type/size, supply and installation of electric storage water heater (vertical type geyser minimum 5 star rating, 25 ltr capacity 240 V, AC single phase having stainless steel inner tank incl heavy duty pin type fasteners 4" long and PVC flexible connection pipe as per site requirement incl plug in top 15 amp and making necessary inlet/outlet water connection and making good disturbed surface of walls to match with existing surface complete all as specified. Note-old unserviceable electric water heater to be deposited in MES store yard.
M/s Sheetal Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .