Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAdmitted-Finance FIRST FLOOR 1115 SECTOR 17B 1115 FIRST FLOOR SECTOR 17B GURUGRAM GURGAON HARYANA HARYANA GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | ₹13.6 L | L1 | Admitted-Finance |
| 2 | L2₹14.1 L+₹58,650 (4.33%)Admitted-Finance | ₹14.1 L+₹58,650 (4.33%) | L2 | Admitted-Finance |
| 3 | L3₹14.2 L+₹68,920 (5.09%)Admitted-Finance | ₹14.2 L+₹68,920 (5.09%) | L3 | Admitted-Finance |
| 4 | L4₹15.7 L+₹2.1 L (15.6%)Admitted-Finance | ₹15.7 L+₹2.1 L (15.6%) | L4 | Admitted-Finance |
| 5 | L5₹18.2 L+₹4.6 L (33.9%)Admitted-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | ₹18.2 L+₹4.6 L (33.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AIRVIEW L1 | MAHESH KR L7 | Power Care Electrical L5 | Q-mech engineering L3 | HVAC L2 | AJESH KK L6 | IQRAH AIRCONDITIONING COMPANY L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00HIGH SIDE (MACHINES) Ceiling Suspended INVERTER Ductable Split A/c Units Supply of Ceiling Suspended INVERTER Ductable Split AC Units of specified capacities,nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A or superior Gas, vibration isolation pads etc. Suitable to work till 52 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, Refrigerant Cooled PCB, Longer Piping Up to 60 Meters, Remote control controlable from inside the room with necessory control wiring up to 60meters of make Bluestar, Daikin, Hitachi,LG. | ||||||||||
| 1.10 | 11 TR INVERTER DUCTABLE | 2 | Nos | 3,05,000 ₹6,10,000 | 4,10,000 ₹8,20,000 | 3,95,000 ₹7,90,000 | 3,00,000 ₹6,00,000 | 2,62,980.75 ₹5,25,961.5 Lowest | 3,90,000 ₹7,80,000 | 2,66,149 ₹5,32,298 |
| 1.20 | 5.5 TR INVERTER DUCTABLE | 1 | Nos | 1,80,000 ₹1,80,000 | 2,50,000 ₹2,50,000 | 2,10,000 ₹2,10,000 | 1,72,500 ₹1,72,500 | 1,60,775 ₹1,60,775 | 2,20,000 ₹2,20,000 | 1,60,586 ₹1,60,586 Lowest |
| 2.00LOW SIDE (MACHINES) Installation,Testing and Commissioning of Ceiling Suspended Ductable Split AC Units of specified capacities,nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A or superior Gas, vibration isolation pads etc. Suitable to work till 52 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, Refrigerant Cooled PCB, Longer Piping Up to 60 Meters of make Bluestar, Daikin, Hitachi,LG. | ||||||||||
| 2.10 | 11 TR INVERTER DUCTABLE | 2 | Nos | 25,000 ₹50,000 | 29,500 ₹59,000 | 30,000 ₹60,000 | 10,990 ₹21,980 Lowest | 25,075 ₹50,150 | 29,500 ₹59,000 | 22,000 ₹44,000 |
| 2.20 | 5.5 TR INVERTER DUCTABLE | 1 | Nos | 25,000 ₹25,000 | 22,000 ₹22,000 | 25,000 ₹25,000 | 5,490 ₹5,490 Lowest | 25,075 ₹25,075 | 24,000 ₹24,000 | 12,000 ₹12,000 |
| 3.00Copper piping with Insulation Refrigerant Piping for above units including Copper Soft/Hard pipes, fittings, supports, saddle, 9/10 mm thick Nitrile Rubber Insulation, PVC sleeves, Pressure Testing, Evaculation & Commissioning (Minor civil works like brick wall chasing/partition cutting to be done by a/c contractor& markings for major civil work to be provided by a/c contractors. | ||||||||||
| 3.10 | Ceiling Suspended Inverter Ductable Split Unit | 57 | Rmt | 1,800 ₹1,02,600 Lowest | 2,850 ₹1,62,450 | 2,800 ₹1,59,600 | 2,400 ₹1,36,800 | 2,336.4 ₹1,33,174.8 | 2,900 ₹1,65,300 | 3,300 ₹1,88,100 |
| 3.20 | R410 or superior Refrigerant Gas | 28 | KG | 1,000 ₹28,000 | 2,500 ₹70,000 | 2,100 ₹58,800 | 500 ₹14,000 Lowest | 1,156.4 ₹32,379.2 | 2,200 ₹61,600 | 2,000 ₹56,000 |
| 4.00Communication Cabling Cabling from Indoor Panel to outdoor unit as per the following specifications with supports, earthing, terminations & testing.Power cables to be sized based on rated load and to be terminated at outdoor units and at indoor units for larger machines. | ||||||||||
Tender Value
₹14.8 L
EMD Value
₹29,600
Closing Date
15 Jun 2026, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
SITC of Air-conditioning System for computer-based testing centre for placement/internship drive
2026_NITC_910082_1
Engg/EMU/JE II/56/CBT-CCD HVAC/2026-27
Open Tender
Electrical Works
Item Rate
120 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹29,600
Yes
21 Jul 2026
25 May 2026
17 Jun 2026
25 May 2026
15 Jun 2026
25 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1HIGH SIDE (MACHINES) Ceiling Suspended INVERTER Ductable Split A/c Units Supply of Ceiling Suspended INVERTER Ductable Split AC Units of specified capacities,nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A or superior Gas, vibration isolation pads etc. Suitable to work till 52 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, Refrigerant Cooled PCB, Longer Piping Up to 60 Meters, Remote control controlable from inside the room with necessory control wiring up to 60meters of make Bluestar, Daikin, Hitachi,LG. | |||||
| 1.1 | 11 TR INVERTER DUCTABLE | - | Nos | - | - |
| 1.2 | 5.5 TR INVERTER DUCTABLE | - | Nos | - | - |
| 2LOW SIDE (MACHINES) Installation,Testing and Commissioning of Ceiling Suspended Ductable Split AC Units of specified capacities,nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A or superior Gas, vibration isolation pads etc. Suitable to work till 52 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, Refrigerant Cooled PCB, Longer Piping Up to 60 Meters of make Bluestar, Daikin, Hitachi,LG. | |||||
| 2.1 | 11 TR INVERTER DUCTABLE | - | Nos | - | - |
| 2.2 | 5.5 TR INVERTER DUCTABLE | - | Nos | - | - |
| 3Copper piping with Insulation Refrigerant Piping for above units including Copper Soft/Hard pipes, fittings, supports, saddle, 9/10 mm thick Nitrile Rubber Insulation, PVC sleeves, Pressure Testing, Evaculation & Commissioning (Minor civil works like brick wall chasing/partition cutting to be done by a/c contractor& markings for major civil work to be provided by a/c contractors. | |||||
| 3.1 | Ceiling Suspended Inverter Ductable Split Unit | - | Rmt | - | - |
| 3.2 | R410 or superior Refrigerant Gas | - | KG | - | - |
| 4Communication Cabling Cabling from Indoor Panel to outdoor unit as per the following specifications with supports, earthing, terminations & testing.Power cables to be sized based on rated load and to be terminated at outdoor units and at indoor units for larger machines. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
BOQ_956495.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .