GEMC-511687712668474
Awarded to ELECTRO CORR DAMP PRIVATE LIMITED
₹2.5 Cr
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| PL CP CP STN MONITORING MMBPL SHERPUR MALARNA | INDIAN / NO | 9983 | 8 EA | 29,310.02 | 234,480.16 |
| PL CP PSP MONITORING MMBPL SHERPUR MALARNA | INDIA | 9983 | 6 EA | 205,177.22 | 1,231,063.32 |
| PL CP ON OFF SURVEY MMBPL SHERPUR MALARNA | INDIA | 9983 | 2 EA | 205,177.22 | 410,354.44 |
| PL CP CP STN MONITORING BKPL CH 152 KOTA | - | 9983 | 8 EA | 21,982.22 | 175,857.76 |
| PL CP PSP MONITORING BKPL CH 152 KOTA | INDIA / NA | 9983 | 6 EA | 83,590.02 | 501,540.12 |
| PL CP ON OFF SURVEY BKPL CH 152 KOTA | INDIA / NA | 9983 | 2 EA | 83,590.02 | 167,180.04 |
| PL CP CP STN MONITORING KJPL | INDIA / NA | 9983 | 8 EA | 21,982.22 | 175,857.76 |
| PL CP PSP MONITORING KJPL | INDIA / NA | 9983 | 6 EA | 159,582.02 | 957,492.12 |
| PL CP ON OFF SURVEY KJPL | INDIA / NA | 9983 | 2 EA | 159,582.02 | 319,164.04 |
| PL CP VISIT CHARGES CP BREAKDOWN | INDIA / NA | 9983 | 100 DAY | 3,538.82 | 353,882 |
| VISIT PL LOCATION | INDIA / NA | 9983 | 48 DAY | 4,270.42 | 204,980.16 |
| PL DEPTH MEASUREMENT SOIL COVER | INDIA / NA | 9983 | 10 KM | 4,270.42 | 42,704.2 |
| PL CP DATA RECORDING 24 HRS | INDIA / NA | 9983 | 20 EA | 5,828.02 | 116,560.4 |
| PL CP DATA RECORDING 48 HRS | INDIA / NA | 9983 | 5 EA | 8,058.22 | 40,291.1 |
| PL CP MAINT PL CBL CONN PIN BRAZING | INDIA / NA | 9983 | 24 NO | 5,155.42 | 123,730.08 |
| PL CP MAINT SUPLY INST OF TLP A TYPE | INDIA / NA | 9983 | 10 NO | 18,784.42 | 187,844.2 |
| PL CP MAINT SUPLY INST OF TLP M TYPE | INDIA / NA | 9983 | 5 NO | 21,238.82 | 106,194.1 |
| PL CP MAINT CONCRETE OF TLP | INDIA / NA | 9983 | 5 NO | 10,618.82 | 53,094.1 |
| PL CP MAINT TLP REPAIR MAINTENANCE | INDIA / NA | 9983 | 50 NO | 2,358.82 | 117,941 |
| PL CP MAINT TLP BOX SHIFTING | INDIA / NA | 9983 | 5 EA | 6,217.42 | 31,087.1 |
| PL CP MAINT SUP KOH KIRK CELL MAINTENANCE | INDIA / NA | 9983 | 5 NO | 1,178.82 | 5,894.1 |
| PL CP MAINT SUP INSTALL POLARIZATION COUPON | INDIA / NA | 9983 | 8 NO | 7,078.82 | 56,630.56 |
| PL CP MAINT SUPnLAY REF CELL | INDIA / NA | 9983 | 20 NO | 20,058.82 | 401,176.4 |
| PL CP MAINT SUP INST SSPC | INDIA / NA | 9983 | 10 NO | 72,120.42 | 721,204.2 |
| PL CP MAINT ANODE BED MAINTENANCE | INDIA / NA | 9983 | 5 EA | 58,998.82 | 294,994.1 |
| PL CP MAINT SUP INSTALL SURGE DIVERTER | INDIA / NA | 9983 | 5 NO | 17,840.42 | 89,202.1 |
| PL CP MAINT TLP DOOR REPLACEMENT | INDIA / NA | 9983 | 100 NO | 3,302.82 | 330,282 |
| PL CP MAINT JOINTING OF CABLE | INDIA / NA | 9983 | 24 NO | 3,727.62 | 89,462.88 |
| PL CP S L CABLE 1C X 6 SQ MM | INDIA / NA | 9983 | 100 M | 140.42 | 14,042 |
| PL CP S L CABLE 1C X 10 SQ MM | INDIA / NA | 9983 | 200 M | 199.42 | 39,884 |
| PL CP S L CABLE 1C X 35 SQ MM | INDIA / NA | 9983 | 400 M | 541.62 | 216,648 |
| PL CP S L CABLE 4C X 10SQ MM | INDIA / NA | 9983 | 50 M | 624.22 | 31,211 |
| PL CP PMT COATING SURVEY CIPL | INDIA / NA | 9983 | 5 KM | 10,618.82 | 53,094.1 |
| PL CP PMT COATING SURVEY CAT | INDIA / NA | 9983 | 5 KM | 10,618.82 | 53,094.1 |
| PL CP PMT COATING SURVEY DCVG | INDIA / NA | 9983 | 10 KM | 10,618.82 | 106,188.2 |
| PL CVL EX FOR INSPN TPW DEPTH 0 1.5 M | INDIA / NA | 9983 | 300 M3 | 470.82 | 141,246 |
| PL CVL EX FOR INSPN TPW DEPTH 1.5 3.0 M | INDIA / NA | 9983 | 300 M3 | 706.82 | 212,046 |
| PL CVL BORING UPTO 3 M | INDIA / NA | 9983 | 5 EA | 8,258.82 | 41,294.1 |
| PL CVL BORING UPTO 6 M | INDIA / NA | 9983 | 5 EA | 10,618.82 | 53,094.1 |
| PL CP MAINT TLP PAINTING | INDIA / NA | 9983 | 100 NO | 942.82 | 94,282 |
| PL CP MAINT AJB PAINTING | INDIA / NA | 9983 | 10 NO | 1,650.82 | 16,508.2 |
| PL CP MAINT SUP LAY GROUND ANODE | INDIA / NA | 9983 | 20 NO | 22,454.22 | 449,084.4 |
| PL CP MAINT SUP LAY HDPE SHEET 8 MM THK | INDIA / NA | 9983 | 30 M2 | 1,768.82 | 53,064.6 |
| PL CP MAINT SUPPLYnINST ANODES MMO ANODE | INDIA / NA | 9983 | 10 NO | 52,036.82 | 520,368.2 |
| PL CP MAINT COMPRESSOR FOR CASING PIPE CLEANING | INDIA / NA | 9983 | 10 S08 | 12,978.82 | 129,788.2 |
| PLM MECH WK END SEAL INSTL 20 INCH 14 INCH | INDIA / NA | 9983 | 2 EA | 89,678.82 | 179,357.64 |
| PLM MECH WK END SEAL INSTL 22 INCH 16 INCH | INDIA / NA | 9983 | 4 EA | 93,218.82 | 372,875.28 |
| PLM MECH WK END SEAL INSTL 24 INCH 18 INCH | INDIA / NA | 9983 | 2 EA | 94,398.82 | 188,797.64 |
| PLM MECH WK ADD VENT DRAIN PIPE 3 INCH SIZE | INDIA / NA | 9983 | 25 M | 9,438.82 | 235,970.5 |
| PL CP MAINT SOIL RESISTIVITY SURVEY | INDIA / NA | 9983 | 10 EA | 5,898.82 | 58,988.2 |
| PL CP MAINT SUP INSTALLATION OF SHUNT | INDIA / NA | 9983 | 10 NO | 706.82 | 7,068.2 |
| PL CP MAINT SUP INSTALL METALLIC CIRCUIT DIAGRAM | INDIA / NA | 9983 | 25 EA | 470.82 | 11,770.5 |
| PL CP MAINT SUP INSTALL ZINC RIBBON ANODE | INDIA / NA | 9983 | 50 M | 1,886.82 | 94,341 |
| PL CP MAINT SUP INSTALL VARIABLE RESISTOR | INDIA / NA | 9983 | 10 NO | 706.82 | 7,068.2 |
| VISIT OF NACE CP LEVEL 3 EXPERT AT SITE | INDIA / NA | 9983 | 5 MDY | 35,398.82 | 176,994.1 |
| PL CP MAINT SUP LAYING OF AC MITIGATOR | INDIA / NA | 9983 | 50 M | 3,538.82 | 176,941 |
| S I DEEP WELL ANODE BED | INDIA / NA | 9983 | 1 NO | 1,174,051.62 | 1,174,051.62 |
| S I MG ANODES CP S M | INDIA / NA | 9983 | 6 NO | 30,183.22 | 181,099.32 |
| PL CP CP STN MONITORING BKPL BINA CH152 | INDIA / NA | 9983 | 8 EA | 21,982.22 | 175,857.76 |
| PL CP PSP MONITORING BKPL BINA CH152 | INDIA / NA | 9983 | 6 EA | 115,509.02 | 693,054.12 |
| PL CP ON OFF SURVEY BKPL BINA CH152 | INDIA / NA | 9983 | 2 EA | 115,509.02 | 231,018.04 |
| PL CP CP STN MONITORING BPPL BINA IP01 | INDIA / NA | 9983 | 8 EA | 21,982.22 | 175,857.76 |
| PL CP PSP MONITORING BPPL BINA IP01 | INDIA / NA | 9983 | 6 EA | 136,784.42 | 820,706.52 |
| PL CP ON OFF SURVEY BPPL BINA IP01 | INDIA / NA | 9983 | 2 EA | 136,784.42 | 273,568.84 |
| PL CP VISIT CHARGES CP BREAKDOWN | INDIA | 9983 | 100 EA | 3,538.82 | 353,882 |
| VISIT PL LOCATION | INDIA / NA | 9983 | 24 DAY | 4,270.42 | 102,490.08 |
| PL DEPTH MEASUREMENT SOIL COVER | INDIA / NA | 9983 | 5 KM | 4,270.42 | 21,352.1 |
| PL CP DATA RECORDING 24 HRS | INDIA / NA | 9983 | 10 EA | 5,828.02 | 58,280.2 |
| PL CP DATA RECORDING 48 HRS | INDIA / NA | 9983 | 10 EA | 8,058.22 | 80,582.2 |
| PL CP MAINT PL CBL CONN PIN BRAZING | INDIA / NA | 9983 | 15 NO | 5,155.42 | 77,331.3 |
| PL CP MAINT SUPLY INST OF TLP A TYPE | INDIA / NA | 9983 | 5 NO | 18,784.42 | 93,922.1 |
| PL CP MAINT SUPLY INST OF TLP M TYPE | INDIA / NA | 9983 | 5 NO | 21,238.82 | 106,194.1 |
| PL CP MAINT CONCRETE OF TLP | INDIA / NA | 9983 | 5 NO | 10,618.82 | 53,094.1 |
| PL CP MAINT TLP REPAIR MAINTENANCE | INDIA / NA | 9983 | 50 NO | 2,358.82 | 117,941 |
| PL CP MAINT TLP BOX SHIFTING | INDIA / NA | 9983 | 5 EA | 6,217.42 | 31,087.1 |
| PL CP MAINT SUP KOH KIRK CELL MAINTENANCE | INDIA / NA | 9983 | 5 NO | 1,178.82 | 5,894.1 |
| PL CP MAINT SUP INSTALL POLARIZATION COUPON | INDIA / NA | 9983 | 5 NO | 7,078.82 | 35,394.1 |
| PL CP MAINT SUP LAY REF CELL | INDIA / NA | 9983 | 10 NO | 20,058.82 | 200,588.2 |
| PL CP MAINT SUP INST SSPC | INDIA / NA | 9983 | 5 NO | 72,120.42 | 360,602.1 |
| PL CP MAINT ANODE BED MAINTENANCE | INDIA / NA | 9983 | 3 EA | 58,998.82 | 176,996.46 |
| PL CP MAINT SUP INSTALL SURGE DIVERTER | INDIA / NA | 9983 | 5 NO | 17,840.42 | 89,202.1 |
| PL CP MAINT TLP DOOR REPLACEMENT | INDIA / NA | 9983 | 75 NO | 3,302.82 | 247,711.5 |
| PL CP MAINT JOINTING OF CABLE | INDIA / NA | 9983 | 24 NO | 3,727.62 | 89,462.88 |
| PL CP S L CABLE 1C X 6 SQ MM | INDIA / NA | 9983 | 50 M | 140.42 | 7,021 |
| PL CP S L CABLE 1C X 10 SQ MM | INDIA / NA | 9983 | 100 M | 199.42 | 19,942 |
| PL CP S L CABLE 1C X 35 SQ MM | INDIA / NA | 9983 | 200 M | 541.62 | 108,324 |
| PL CP S L CABLE 4C X 10SQ MM | INDIA / NA | 9983 | 50 M | 624.22 | 31,211 |
| PL CP PMT COATING SURVEY CIPL | INDIA / NA | 9983 | 5 KM | 10,618.82 | 53,094.1 |
| PL CP PMT COATING SURVEY CAT | INDIA / NA | 9983 | 5 KM | 10,618.82 | 53,094.1 |
| PL CP PMT COATING SURVEY DCVG | INDIA / NA | 9983 | 10 KM | 10,618.82 | 106,188.2 |
| PL CVL EX FOR INSPN TPW DEPTH 0 1.5 M | INDIA / NA | 9983 | 200 M3 | 470.82 | 94,164 |
| PL CVL EX FOR INSPN TPW DEPTH 1.5 3.0 M | INDIA / NA | 9983 | 200 M3 | 706.82 | 141,364 |
| PL CVL BORING UPTO 3 M | INDIA / NA | 9983 | 5 EA | 8,258.82 | 41,294.1 |
| PL CVL BORING UPTO 6 M | INDIA / NA | 9983 | 5 EA | 10,618.82 | 53,094.1 |
| PL CP MAINT TLP PAINTING | INDIA / NA | 9983 | 150 NO | 942.82 | 141,423 |
| PL CP MAINT AJB PAINTING | INDIA / NA | 9983 | 20 NO | 1,650.82 | 33,016.4 |
| PL CP MAINT SUP LAY GROUND ANODE | INDIA / NA | 9983 | 20 NO | 22,454.22 | 449,084.4 |
| PL CP MAINT SUP LAY HDPE SHEET 8 MM THK | INDIA / NA | 9983 | 30 M2 | 1,768.82 | 53,064.6 |
| PL CP MAINT SUPPLY INST ANODES MMO ANODE | INDIA / NA | 9983 | 5 NO | 52,036.82 | 260,184.1 |
| PL CP MAINT COMPRESSOR FOR CASING PIPE CLEANING | INDIA / NA | 9983 | 6 S08 | 12,978.82 | 77,872.92 |
| PLM MECH WK END SEAL INSTL 24 INCH 18 INCH | INDIA / NA | 9983 | 4 EA | 94,398.82 | 377,595.28 |
| PLM MECH WK ADD VENT DRAIN PIPE 3 INCH SIZE | INDIA / NA | 9983 | 25 M | 9,438.82 | 235,970.5 |
| PL CP MAINT SOIL RESISTIVITY SURVEY | INDIA / NA | 9983 | 10 EA | 5,898.82 | 58,988.2 |
| PL CP MAINT SUP INSTALLATION OF SHUNT | INDIA / NA | 9983 | 10 NO | 706.82 | 7,068.2 |
| PL CP MAINT SUP INSTALL METALLIC CIRCUIT DIAGRAM | INDIA / NA | 9983 | 25 EA | 470.82 | 11,770.5 |
| PL CP MAINT SUP INSTALL ZINC RIBBON ANODE | INDIA / NA | 9983 | 50 M | 1,886.82 | 94,341 |
| PL CP MAINT SUP INSTALL VARIABLE RESISTOR | INDIA / NA | 9983 | 10 NO | 706.82 | 7,068.2 |
| VISIT OF NACE CP LEVEL 3 EXPERT AT SITE | INDIA / NA | 9983 | 5 MDY | 35,398.82 | 176,994.1 |
| PL CP MAINT SUP LAYING OF AC MITIGATOR | INDIA / NA | 9983 | 50 M | 3,538.82 | 176,941 |
| S I MG ANODES CP S M | INDIA / NA | 9983 | 6 NO | 30,183.22 | 181,099.32 |
| PL CP CP STN MONITORING BPPL IP01 PANKI | INDIA / NA | 9983 | 8 EA | 21,982.22 | 175,857.76 |
| PL CP PSP MONITORING BPPL IP01 PANKI | INDIA / NA | 9983 | 6 EA | 133,751.82 | 802,510.92 |
| PL CP ON OFF SURVEY BPPL IP01 PANKI | INDIA / NA | 9983 | 2 EA | 133,751.82 | 267,503.64 |
| PL CP VISIT CHARGES CP BREAKDOWN | INDIA / NA | 9983 | 48 EA | 3,538.82 | 169,863.36 |
| VISIT PL LOCATION | INDIA / NA | 9983 | 24 DAY | 4,270.42 | 102,490.08 |
| PL DEPTH MEASUREMENT SOIL COVER | INDIA / NA | 9983 | 5 KM | 4,270.42 | 21,352.1 |
| PL CP DATA RECORDING 24 HRS | INDIA / NA | 9983 | 8 EA | 5,828.02 | 46,624.16 |
| PL CP DATA RECORDING 48 HRS | INDIA / NA | 9983 | 5 EA | 8,058.22 | 40,291.1 |
| PL CP MAINT PL CBL CONN PIN BRAZING | INDIA / NA | 9983 | 12 NO | 5,155.42 | 61,865.04 |
| PL CP MAINT SUPLY INST OF TLP A TYPE | INDIA / NA | 9983 | 5 NO | 18,784.42 | 93,922.1 |
| PL CP MAINT SUPLY INST OF TLP M TYPE | INDIA / NA | 9983 | 5 NO | 21,238.82 | 106,194.1 |
| PL CP MAINT CONCRETE OF TLP | INDIA / NA | 9983 | 5 NO | 10,618.82 | 53,094.1 |
| PL CP MAINT TLP REPAIR MAINTENANCE | INDIA / NA | 9983 | 5 NO | 2,358.82 | 11,794.1 |
| PL CP MAINT TLP BOX SHIFTING | INDIA / NA | 9983 | 2 EA | 6,217.42 | 12,434.84 |
| PL CP MAINT SUP KOH KIRK CELL MAINTENANCE | INDIA / NA | 9983 | 2 NO | 1,178.82 | 2,357.64 |
| PL CP MAINT SUP INSTALL POLARIZATION COUPON | INDIA / NA | 9983 | 5 NO | 7,078.82 | 35,394.1 |
| PL CP MAINT SUPnLAY REF CELL | INDIA / NA | 9983 | 5 NO | 20,058.82 | 100,294.1 |
| PL CP MAINT SUP INST SSPC | INDIA / NA | 9983 | 5 NO | 72,120.42 | 360,602.1 |
| PL CP MAINT ANODE BED MAINTENANCE | INDIA / NA | 9983 | 2 EA | 58,998.82 | 117,997.64 |
| PL CP MAINT SUP INSTALL SURGE DIVERTER | INDIA / NA | 9983 | 4 NO | 17,840.42 | 71,361.68 |
| PL CP MAINT TLP DOOR REPLACEMENT | INDIA / NA | 9983 | 20 NO | 3,302.82 | 66,056.4 |
| PL CP MAINT JOINTING OF CABLE | INDIA / NA | 9983 | 20 NO | 3,727.62 | 74,552.4 |
| PL CP S L CABLE 1C X 6 SQ MM | INDIA / NA | 9983 | 50 M | 140.42 | 7,021 |
| PL CP S L CABLE 1C X 10 SQ MM | INDIA / NA | 9983 | 100 M | 199.42 | 19,942 |
| PL CP S L CABLE 1C X 35 SQ MM | INDIA / NA | 9983 | 100 M | 541.62 | 54,162 |
| PL CP S L CABLE 4C X 10SQ MM | INDIA / NA | 9983 | 50 M | 624.22 | 31,211 |
| PL CP PMT COATING SURVEY CIPL | INDIA / NA | 9983 | 2 KM | 10,618.82 | 21,237.64 |
| PL CP PMT COATING SURVEY CAT | INDIA / NA | 9983 | 5 KM | 10,618.82 | 53,094.1 |
| PL CP PMT COATING SURVEY DCVG | INDIA / NA | 9983 | 10 KM | 10,618.82 | 106,188.2 |
| PL CVL EX FOR INSPN TPW DEPTH 0 1.5 M | INDIA / NA | 9983 | 100 M3 | 470.82 | 47,082 |
| PL CVL EX FOR INSPN TPW DEPTH 1.5 3.0 M | INDIA / NA | 9983 | 100 M3 | 706.82 | 70,682 |
| PL CVL BORING UPTO 3 M | INDIA / NA | 9983 | 3 EA | 8,258.82 | 24,776.46 |
| PL CVL BORING UPTO 6 M | INDIA / NA | 9983 | 3 EA | 10,618.82 | 31,856.46 |
| PL CP MAINT TLP PAINTING | INDIA / NA | 9983 | 100 NO | 942.82 | 94,282 |
| PL CP MAINT AJB PAINTING | INDIA / NA | 9983 | 5 NO | 1,650.82 | 8,254.1 |
| PL CP MAINT SUP LAY GROUND ANODE | INDIA / NA | 9983 | 5 NO | 22,454.22 | 112,271.1 |
| PL CP MAINT SUP LAY HDPE SHEET 8 MM THK | INDIA / NA | 9983 | 15 M2 | 1,768.82 | 26,532.3 |
| PL CP MAINT SUPPLYnINST ANODES MMO ANODE | INDIA / NA | 9983 | 5 NO | 52,036.82 | 260,184.1 |
| PL CP MAINT COMPRESSOR FOR CASING PIPE CLEANING | INDIA / NA | 9983 | 4 S08 | 12,978.82 | 51,915.28 |
| PLM MECH WK END SEAL INSTL 24 INCH 18 INCH | INDIA / NA | 9983 | 2 EA | 94,398.82 | 188,797.64 |
| PLM MECH WK ADD VENT DRAIN PIPE 3 INCH SIZE | INDIA / NA | 9983 | 25 M | 9,438.82 | 235,970.5 |
| PL CP MAINT SOIL RESISTIVITY SURVEY | INDIA / NA | 9983 | 5 EA | 5,898.82 | 29,494.1 |
| PL CP MAINT SUP INSTALLATION OF SHUNT | INDIA / NA | 9983 | 10 NO | 706.82 | 7,068.2 |
| PL CP MAINT SUP INSTALL METALLIC CIRCUIT DIAGRAM | INDIA / NA | 9983 | 10 EA | 470.82 | 4,708.2 |
| PL CP MAINT SUP INSTALL ZINC RIBBON ANODE | INDIA / NA | 9983 | 50 M | 1,886.82 | 94,341 |
| PL CP MAINT SUP INSTALL VARIABLE RESISTOR | INDIA / NA | 9983 | 10 NO | 706.82 | 7,068.2 |
| VISIT OF NACE CP LEVEL 3 EXPERT AT SITE | INDIA / NA | 9983 | 4 MDY | 35,398.82 | 141,595.28 |
| PL CP MAINT SUP LAYING OF AC MITIGATOR | INDIA / NA | 9983 | 25 M | 3,538.82 | 88,470.5 |
| S I MG ANODES CP S M | INDIA / NA | 9983 | 4 NO | 30,183.22 | 120,732.88 |