Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹36.3 Cr
EMD Value
₹36.3 L
Closing Date
31 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
NBCC/RBG/South/NMPA/Mangaluru/Karnataka/2026/49~EWd18b8e7bfcf6858398e70c1e
NBCC/RBG/South/NMPA/Mangaluru/Karnataka/2026/49
Open Tender-Domestic
Civil Works - Others
NBCC Bhawan
₹59,000
₹36.3 L
10 Oct 2026
10 Oct 2026
31 Oct 2026
10 Oct 2026
31 Oct 2026
GRAND TOTAL 36,26,10,323
Earth work excavation for Foundation by mechanical means for all works & depth
upto 3 m, as per drawing and technical specifications, including setting out, shoring,
KPWD Vol. 1 strutting, barricading, caution lights, including dressing of excavated surfaces,
1.14 disposing off or levelling the excavated earth or sorting & stacking the selected earth
for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of
machinery & other appurtenaces required to complete the Work
3 In all kinds of soils Depth upto 3 m Cum 6,742.00 120.36 8,11,467.12
KPWD Vol. 1 Providing and Filling in foundation with granite / trap broken metal 100mm. And
1.23 down size & with approved sand including hand packing, ramming, watering, including
4 cost of all materials and labour with all lead and lift complete as perspecifications. Cum 5,680.00 3,164.76 1,79,75,836.80
Providing and laying in position Cement Concrete for levelling course for all works in
foundation. The granite/trap/basalt crushed graded coarse aggregates and fine
5 aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150
mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all
materials of quality, labour, Usage charges of machinery, curing, and all the other
6 Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Cum 201.00 7,336.06 14,74,548.06
Providing and laying in position Cement Concrete for all Foundation works. The
granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per
relevant IS Codes machine mixed with super plasticizers laid in finished layers, well
7 compacted using needle vibrators, including all lead & lifts, cost of all materials, quality
confirming to the requirements of relevant IS codes, labour, Usage charges of
machinery, curing and all the other appurtenances required to complete the work as
per technical specifications.
8 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum 946.00 7,668.82 72,54,703.72
Providing and laying in Cement Concrete for all Basement & surface level works,
return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded
coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
9 super plasticisers, laid in layers, well compacted using needle vibrators, providing weep
holes wherever necessary, including all lead & lifts, cost of all materials of quality,
labour, Usage charges of machinery, curing and all other appurtenances required to
complete the work as per technical specifications.
10 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum 88.00 7,793.90 6,85,863.20
Supply and placing the Design Mix of M-30 Grade for Self Compacting Concrete
corresponding to IS 456-2000 (Re-affirmed 2021) and relevant IS codes using Batching
plant, Transit mixer and concrete pump with 12.5 mm size graded machine crushed
hard metal (coarse aggregate) from approved quarry including cost and conveyance of
all materials like cement, cement substitutes like fly ash, GGBS, etc., fine aggregate
11 (sand), coarse aggregate, Admixture, water etc., to site including and sales and other
taxes on all materials including all operational, incidental and labour charges, but
excluding cost of steel and its fabrication & formwork charges for finished item of work
with minimum cement content as per IS code including pumping & curing etc
complete for finished item of work (RCC slabs, Beams, Columns, Lintels, Water Tanks,
RCC Walls in Buildings).
Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of
13 all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking,
laping/welding joints, tying with binding wire / soft annealed steel wire and other
ancilary operations complete as per drawing and technical specification.
14 All other type of structures MT 218.00 93,232.98 2,03,24,789.64
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite
Treatment, creating continuous chemical barrier under and around the column pits,
walls, trenches, basement, excavation, top surface of the plinth filling, junction of wall
KPWD Vol. 2 and floor, along the external perimeter of building, expansion joints, over the top
4.1 surface of consolidated earth on which apron is to be laid, surrounding of pipes and
conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of
chemical, diluting in water to one percent concentration, labour, usage charges of
machinery, complete as per specifications.
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster
with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement
KPWD Vol.2 plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge
8.9 to brick masonry including rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials, labour, curing
complete as per specifications and as per directions of Engineer-in-charge.
ASID CONSULTANTS 3/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Finishing walls with Premium Acrylic Smooth exterior paint with
Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up
resistant, Alkali & Water resistant of required shade: New work (Two
coats applied @ 1.43 L/10 m² over and including priming coat of exterior
17 primer applied @ 2.20 kg/10 m²) with paint of approved quality to give Sqm 5,438.00 210.04 11,42,197.52
an even shade, after thoroughly brooming the surface to remove all dirt,
dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge
Providing and applying white cement based putty of average thickness 1 mm, of
KPWD Vol.2 approved brand and manufacturer, over the plastered wall surface to prepare the
8.51 surface even and smooth complete as per specifications and as per directions of
Engineer in charge.
19 Centering and shuttering including strutting, propping etc. and removal of form for
20 Foundations, footings, bases of columns, etc. for mass concrete Sqm 1,028.00 381.56 3,92,245.68
CPWD Walls (any thickness) including attached pilasters, butteresses, plinth and string
5.9.2 courses etc.
22 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 572.00 935.34 5,35,017.28
Structural steel works Conforming to IS:2062 [E 350 (Fe 490) A] with minimum yield
stress 350 Mpa Including supplying and fabrication in portal frames/ rafter/ beams/
purlins made from plates/standard members, foundation bolts etc., connected to one
another with brackets, gussets, cleats, bolted and/or welded etc., as per design
direction, complete including transportation from owner's/client's steel yard/godown,
loading/ unloading at clients/owners shop/fabrication yard, fabrication including
preparing shop layout/ template, flame cutting, straightening, bending necessary,
marking, making holes with drilling machines, fitting, making Jigs & fixtures, welding,
hoisting, including surface preparation as per approved process cleaning of surface
etc., all complete including cost of steel and all other accessories/consumables as per
approved drawing/ specification/ direction of Engineer-in-charge
(Non-Schedule Item)
Providing and applying two coats of epoxy zinc phosphate primer followed by two
coats of high-build epoxy paint to structural steel members, including proper surface
preparation by mechanical cleaning/degreasing, touch-up of damaged primer after
25 B-NS-2 fabrication and erection, and one final finish coat at site after erection to achieve the Kg 4,52,808.00 8.67 39,26,344.80
specified dry film thickness (DFT), complete with all materials, labour, scaffolding, tools
and tackles, as per approved specifications and the directions of the Engineer-in-
Charge (Non-Schedule Item)
Providing and fixing 0.50 mm thick colour coated Galvalume roofing sheets with
effective cover width as per manufacturer's specifications, hot-dip coated with
Aluminium-Zinc-Silicon alloy coating (55% Aluminium, 43.5% Zinc and 1.5% Silicon),
fixed to steel purlins with galvanized iron J/L hooks, 8 mm dia GI bolts, nuts, C.I. plain
26 B-NS-3 washers, bitumen/rubber washers and UV-resistant plastic caps, including cutting, Sqm 10,400.00 1,102.50 1,14,65,994.38
drilling, lapping, alignment, transportation, lifting, handling, all fixtures and
accessories, complete in all respects as per approved drawings and the directions of
the Engineer-in-Charge. (Excluding the cost of purlins, rafters and trusses.)
(Non-Schedule Item)
Providing & Fixing Roofing Ridge Cap made out of 0.47 mm TCT colour coated
Galvalume sheet (55% Aluminium, 43.5% Zinc, 1.5-1.6% Silicon alloy coating) of 1145
mm developed width, machine bent to required profile and fixed over roof ridge with
GI J/L hooks, 8 mm dia GI bolts, MS brackets (25 x 10 mm), nuts, bitumen/rubber
27 B-NS-4 washers and UV-resistant plastic caps, including stitching of overlaps with self-drilling RM 266.00 1,114.87 2,96,554.88
screws to prevent wind uplift, cutting, bending, sealing, all accessories, labour, tools &
tackles, transportation, complete in all respects as per approved drawings and
direction of Engineer-in-Charge.
(Non-Schedule Item)
Providing and fixing 0.50 mm thick colour coated Galvalume side wall cladding sheets
(same specification as roofing sheets), fixed to steel wall girts with GI J/L hooks, self-
28 B-NS-5 drilling screws, washers and accessories, including cutting, drilling, fixing, complete in Sqm 8,250.00 1,102.50 90,95,620.54
all respects as per approved drawings, for shed side walls and gable ends.
(Non-Schedule Item)
Providing and fixing pre-formed GI/Galvalume eaves gutter (size 300 x 150 mm or as
per approved drawing) fixed to roof eaves with brackets at 1 m c/c, including end caps,
29 B-NS-6 outlets, jointing and sealing, complete as per manufacturer's specification and RM 532.00 928.35 4,93,882.55
direction of Engineer-in-Charge.
(Non-Schedule Item)
Providing and fixing 100 mm dia PVC/GI rainwater down-take pipes from eaves gutter
to ground level / storm water drain, including clamps, bends, shoes and fixing,
complete as per direction of Engineer-in-Charge.
(Non-Schedule Item)
Providing and grouting non-shrink, free-flow cementitious grout (GP2 Grouting) of
approved make under column base plates after erection and alignment of structural
31 B-NS-8 steel columns, including formwork/shuttering and curing, complete as per Cum 40.00 50,317.73 20,12,709.18
manufacturer's specification and direction of Engineer-in-Charge.
(Non-Schedule Item)
Providing plain cement concrete (PCC M15) plinth protection / apron of 75 mm
thickness and 500 mm width all around the shed at ground level, including compaction
32 B-NS-9 of sub-grade and expansion joints at 3 m c/c filled with bitumen, complete as per Sqm 1,080.00 769.06 8,30,587.01
direction of Engineer-in-Charge.
(Non-Schedule Item)
Providing rubble stone/boulder filling between or behind abutment below apron
33 including cost of all materials, labour, hand packing, finishing top surface & all Cum 1,030.00 1,508.04 15,53,281.20
necessary works as directed and complete as per specification.
ASID CONSULTANTS 4/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Credit for useful lateritic soil/laterite excavated from foundation excavation and
approved by the Engineer-in-Charge for reuse in filling, backfilling or embankment
works within the site, including handling, loading, transportation and stacking at the
location directed by the Engineer-in-Charge.
Construction of Subgrade and Earthen Shoulders
KPWD Vol. 3 Construction of sub-grade and earthen shoulders with approved material obtained
3.6 from borrow pits with all lifts & leads, transporting to site, spreading, grading to
required slope and compacted to meet requirement of table No. 300-2
Granular Sub-Base
Plant Mix Method
KPWD Vol. 3 Construction of Granular Sub-Base of required grading as per design mixing in a
4.1 mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in
uniform layers with motor grader on prepared surface and compacting with vibratory
power roller to achieve the desired density, complete as per clause 401
37 (v) For Grading -V Material Cum 2,772.00 2,934.66 81,34,877.52
Dry Lean Cement Concrete Sub-base
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with
coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not
exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation
38 after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 Cum 1,386.00 5,805.60 80,46,561.60
, optimum moisture content to be determined during trial length construction,
concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant,
transported to site, laid with a paver with electronic sensor, compacting with 8-10 t
vibratory roller, finishing and curing.
Pavement Quality Concrete using paver - M40 Grade Construction of M40 Grade un-
reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base
in recommended proportions, coarse and fine aggregate conforming to IS 383:2016,
maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and
KPWD Vol. 3 mixing plant as per approved mix design transported to site, laid with a slip form paver
6.2 finisher, spread, compacted and finished in a continuous operation including provision
of contraction, expansion, construction and longitudinal joints, joint filler, separation
membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod,
admixtures, curing compound, steel channels, finishing to lines and grades as per
ASID CONSULTANTS 5/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items
Sl. No. Code/ NS Description of Item Unit Quantity
with CF @0.973 Rates Amount Amount
C Internal Finishing Works
Tile & Stone Works
41 DSR Code Providing and laying Polished Granite stone flooring in required design and patterns, in linear as
well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm
thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand)
11.56 laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of
matching shade including rubbing, curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge.
Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent
a on pathways/ ramps, Sqm 1243.63 4,970.75 61,81,786.29
b Providing and laying Polished Granite stone cladding on walls/ boundary walls, Sqm 4,970.75
AS per DSR Code 11.56
42 8.11 Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining Sqm 87.49 10,133.60 8,86,539.04
(veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever
required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3
(1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3
kg/sqm including pointing with white cement slurry admixed with pigment of matching shade,
including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed
by the Engineer-in-Charge.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of
required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4
(1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,
epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss
finish etc. complete at all levels.
8.2.2 Granite stone slab of colour black, Cherry/Ruby red 26.57 5,267.34 1,39,926.77
44 DSR Code TILES FLOORING IN TOILET Sqm 44.06 1,723.12 75,921.77
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with
water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,
11.41.2 laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/
sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
45 a TILES CLADDING ON TOILET INTERNAL WALL Sqm 148.77 1,723.12 2,56,347.41
Providing and laying in position on walls vitrified tiles:
AS per DSR Code 11.41.2
POLISH & PAINT WORKS
46 DSR Code Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per Sqm 94.61 214.86 20,326.75
manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of
13.48 Special primer applied @ 0.75 ltr /10 sqm
47 DSR Code Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface sqm 50.55 291.39 14,728.62
even and smooth complete.
48 DSR Code Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre sqm 44.06 2,448.05 1,07,862.73
and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per
26.22.1 CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot
dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both
sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of
length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module
of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per
sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-
shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with
precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed
with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey
wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S
screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-
With 15 mm thick Tegular edged light weight calcium sliciate false ceiling
49 DSR Code Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates KG 856.76 -
etc., including welding, grinding, buffing, polishing and making curvature (wherever required)
2.35.2.1 and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the
railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc.,
of required size, on the top of the floor or the side of waist slab with suitable arrangement
as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
50 DSR Code Providing and laying at or near ground level factory made kerb stone of M-25 grade cement CUM 51.54 11,289.20 5,81,879.11
concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except
16.69 at sharp curve shall not to more than 5 mm), including making drainage opening wherever required
complete etc. as per direction of Engineerin-charge (length of finished kerb edging shall be
measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by
Engineer-in-charge).
51 C-NS 11 Providing & fixing GRC Tiles / extruded clay tiles of size 230 x 50 x 15mm for cladding work sqm 124.20 5,669.00 7,04,090
over an underlayer of 12 mm Cement plaster 1:3 (1 cement : 3 fine sand), furrowing the
underlayer with a scratching tool, and jointing with grey cement slurry @ 3.3kg per sqm.
This includes forming uniform grooves of size 8mm x 8mm, alongside the cost of
scaffolding up to 15 meters in height.
ASID CONSULTANTS 6/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
52 C-NS 12 Providing & Fixing PVC garden mesh of size 25x25mm including all materials, labours, sqm 2888.80 5,017.00 1,44,93,110
binding wires, fittings, erection etc., complete as directed by the Engineer in-charge.
53 C-NS 13 ProvidingandfixingGlassFibreReinforcedConcrete(GFRC) Architectural SCREENSinapprovedsize, SQM 155.83 6,992.00 10,89,528
pattern,designshade& internal designthicknessbetween25–30mmandborder thickness
between40–50mmor35mmoverall,asperapproved architectural drawings. GFRCSCREEN Sshall be
manufactured by simultaneously sprayed method. TheGFRCmaterial shall have spray mixde sign
withwhite cementofM/sJKCement,Birla white or equivalent,silicasand,alkali resistant glass fibre of
M/s Owens Corning, N.E.Gorequivalent, polymers of M/s Nova Polychemor equivalent ,
SuperPlasticizersofM/sKarochemor equivalentandwater,pigmentationwithexteriorgradesynthetic
inorganicpigmentsofM/sPhenochemorequivalentsoasto achieveaModulusofRupture(MOR)not
lessthan18MPaandLimitofProportionality(LOP)not lessthan7.0MPa,withglass Fiber contentnot less
than3.5-4%.Theglass fiber shall bealkali resistant (AR)withminimumZirconiumDioxide(ZrO2)
contentof16%and shall be manufactured by approved manufacturer as per specification. The GFRC
material shall not have water absorption of more than 11% by weight. The GRCS CREENS
shouldbe fixed,as per the architectural drawings with dry fixing method on to structural support
members i.e.,R.C.C,Brick worko rRed Oxide Primer-paintor Epoxy primer-paint treated mild steel
(Tobepaidseparately).Thefixing of Panels should be done using‘ Dry fixing’ method on to structural
support membersi.e.,R.C.C,Brick work MS Frame work.MS Galvanized CLAMPS & PINS also if
required fasteners to be used of Steel Grip/HP/ Wurth/ Hilti/ Fischer /Klimas or equivalent. All cast
in socket to be Epoxy Primer Coated. ELECTRODES to beused of Advani, Mangalam, Esab or
Victor brand or equivalent. All grooves should be leftB open for expansion and contraction.
NoSealantwillbeusedfor fillingthegrooves.For final finishing of GRC elements one weather shield
exterior gradewater baseddilutedpaint coatwill bedone if required. Vendors shall submit shop
drawings of the same, the drawings to be duly approved by the Engineer in charge at site
ASID CONSULTANTS 7/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
KPWD item NS Items KPWD /DSR NS Items
Sl. No. Description of Item Unit Quantity Rate with CF
Code/ NS Item Rates Amount Amount
PART D Door and Windows
Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required
54 dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and
sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-
charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) KG 3080.84 516.57 15,91,454
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
DSR CODE etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings
21.3 and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in
21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) SQM 441.60 1,639.89 7,24,177
Providing and fixing ISI marked flush door shutters conforming to IS :
DSR CODE 2202 (Part I) decorative type, core of block board construction with
9.20 frame of 1st class hard wood and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked oxidised M.S. tower bolt black finish,
57 9.63 (Barrel type) with necessary screws etc. complete (Copper oxidised as
Providing and fixing bright finished brass 100 mm mortice latch and
58 9.76 lock with 6 levers and a pair of lever handles of approved quality with EACH 8.00 831.57 6,653
necessary screws etc. complete.
Providing and fixing aluminium die cast body tubular type universal
hydraulic door closer (having brand logo with ISI, IS : 3564, embossed
on the body, door weight upto 35 kg and door width upto 700 mm), with
necessary accessories and screws etc. complete.
TOTAL -PART D 23,89,929 -
ASID CONSULTANTS 8/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
Part E Summary of Electrical Works
S.NO. DESCRIPTION OF WORK NS ITEMS AMOUNT
1 Conduit System 17,39,182.24 0.00
3 SWITCHES, SOCKETS & ACCESSORIES & DBs 3,83,752.10 0.00
4 LIGH, FANS & AIR CONDITIONERS 55,941.44 25,10,520.00
5 NETWORKING & TELECOMUNICATION 1,54,709.80 0.00
6 UPS, VOLTAGE STABILIZERS, BATTERIES &ACCESSORIES 1,36,780.88 0.00
7 EARTHING & CABLE TRAY BATTERY CHARGER 8,02,811.40 0.00
8 SUPPLY OF CABLE 0.00 34,84,510.00
9 HDPE PIPE, MV CABLE JOINTING & END TERMINATION 5,54,376.00 0.00
10 SDB LIGHT & POWER PANEL 0.00 4,55,394.00
11 LIGHTNING CONDUCTOR 5,60,206.40 0.00
12 FIRE ALARM SYSTEM 22,29,305.56 0.00
13 CCTV SYSTEM (IP BASED) 16,77,144.00 0.00
Assumptions /consderations -
1 Main Incoming Power cable
ASID CONSULTANTS 9/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
KPTCL 2023-24 / DSR KPWD Rate/DSR NS Items KPWD /DSR NS Items
Sl. No. Description of Item Unit Qty.
2025/ NS Items Rate Rates Amount Amount
Ref No. Description
Part E1 1.0 Electrical Work
DSR 1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess
60 including painting in case of surface conduit, or cutting the wall and making good the same in
case of recessed conduit as required.
1.10 Supplying Galvanized steel flexible conduit pipe .... mm dia fixing on surface over inverted
tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge
61 saddles at an interval of 300 mm using NF screws and on either end of the pipe
62 2.0 WIRES & CABLES
Point wiring using Copper wire with switch.
2.1 Supplying and wiring adopting loop system in existing PVC Conduit /casing capping
using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC
insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush
type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the
wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for
2.1.1 Short point upto 3Mtr from tapping point to out let via switch Point 4 336.30 1345.2
2.1.2 Medium point above 3Mtr upto 6Mtr from tapping point to out let via
2.1.3 Long point above 6Mtr upto 10Mtr from tapping point to out let via
2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand
copper wire with low conductor resistance single core in open or concealed system of wiring
63 with specified IS-
The following additional tests are compulsory either to be conducted at
works or independent lab with witness by inspecting authority.
2.5 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible
copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation
sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990
65 3.0 SWITCHES, SOCKETS & ACCESSORIES & DBs
3.5 Supplying and fixing superior quality modular switch mounting polycarbonate plate with
necessary supporting back plate with required nos. of machine screws, bolts nuts etc.,
complete on the existing
3.6 Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.
3.6.1 6A One Way Switch Each 24 120.36 2888.64
3.6.7 16A One Way Switch Each 44 212.40 9345.6
3.6.10 6/16A Universal Socket Each 44 278.48 12253.12
3.6.11 TV/Telephone Socket Each 6 184.08 1104.48
3.6.12 RJ45/I.O Outlet Cat-6 Each 24 397.66 9543.84
67 2pole+earth 250V SOCKET
5.17 Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09
tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane
(PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using
required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's
68 as an incomer for 3 phase Double door with necessary bus bar completely wired to use
on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing
of single/three phase suitable capacity MCB's as outgoings confirming to
ASID CONSULTANTS 10/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
5.18 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using
necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short
69 circuit breaking capacity of 10K and complete wiring as required confirming to IEC
5.20 Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA
sensitivity on existing wood/ panel board.
71 6.0 LIGHT, FANS & AIR CONDITIONERS
6.2 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on
230V 50Hz, AC Supply complete.
6.3 Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for
operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with
double ball bearing
11.4 Supplying of recess mounting non integrated type LED down light... W luminaire comprising of
pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps. LED of
Power/COB with CCT 6500 degree K. CRI> 70%. efficacy >100 lumen per W. 120degree beam
spread, life> 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The
lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level.
LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF >
0.95, power loss should< 5% of lamp Wage, short circuit & open circuit protection to be
integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should
be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2
years Warranty against any manufacturing defect working under standard electrical condition.
EL-NS 14 Supply & Installation of 120W LED highbay light round shape suitable for operation on 230V AC
supply with minimum 13020 lumens. as per standard tested for min. 10k hours confirming
minimum 50000 burning hours of life 6500K LED's only. LED Driver shall withstand 2kV surge
EL-NS 15 Supply & Installation of 120W LED Flood light suitable for operation on 230V AC supply with
minimum 13020 lumens. as per standard tested for min. 10k hours confirming minimum 50000
burning hours of life 6500K LED's only. IP 65 protection for external use. LED Driver shall
withstand 2kV surge protection.
75 8.0 NETWORKING & TELECOMUNICATION
8.1 Supplying and drawing UTP-CAT 6E LAN cable. m 1440 44.84 64569.6
8.2 Supplying and drawing PVC flexible one pair telephone unarmoured
tinned copper cable.
8.4 Supplying & Fixing of switch mounting rack with power manager &
77 8.10 Supplying & fixing of I/O socket with back box
78 8.11 Supplying & Fixing of ... ms Cat 6 Patch Cable
79 8.12 Supplying & Fixing of Patch panel for LAN cabling
9.0 UPS, VOLTAGE STABILIZERS, BATTERIES &
9.3 Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for
operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete
and Excluding batteries
and wiring complete.
9.3.2 3 kVA ON LINE UPS Each 2 45688.42 91376.84
9.5 Supplying, installation, testing & commissioning of 12V DC, AH
batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.
EARTHING & CABLE TRAY BATTERY CHARGER
12.58 GI/Copper strips for grounding connections, using necessary fixing
materials as required.
12.58.1 GI/Copper strips
12.59 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI
bolts/nuts and washer or welding as required.
12.60 Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other
equipments backfill compound which is non-corrosive, thermally conductive, potential
84 to permissible limits, superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm
12.60.6 Using 10ft. SS rod with backfill compound 1 kit 4 7351.40 29405.6
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
ASID CONSULTANTS 11/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
SUPPLY OF CABLE
EL-NS 16 Supply of aluminium / copper conductor, XLPE insulated, armuored, PVC sheathed cable, 1100V
grade, at depth of 750mm below ground level including excavation and refling the trench over a
cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top as
86 directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be
properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the
road as required and compaction of soil & repairing of surface in prior shape shall be done
HDPE PIPE, MV CABLE JOINTING & END TERMINATION
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like
socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,
87 2025 DSR 15.16 jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the
trench but excluding sand cushioning and protective covering etc., complete as required.
2025 DSR 15.16.1 63 mm dia (OD-63 mm & ID-51 mm nominal) Metre 200 289.00 57800
2025 DSR 15.16.4 160 mm dia (OD-160 mm & ID-135 mm nominal) Metre 400 537.00 214800
Supplying and making end termination with brass compression gland and aluminium lugs for
88 2025 DSR 11.1 following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL pipe as required.
2025 DSR 10.5.2 Above 35 sq. mm and upto 95 sq. mm Metre 450 72.00 32400
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on cable tray as required.
2025 DSR 10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 3440 53.00 182320
91 EL-NS 17 SDB LIGHT & POWER PANEL
Supply, loading, Unloading, Receiving, Installation, Testing and commissioning of following
panels AS PER IEC : 61439-1&2 suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution
system. The panel shall be Indoor, free standing, floor mounting, sheet metal clad, cubicle, dead
front, dust and vermin proof type compartmentalised design fabricated out of 2mm thick CRCA
sheet steel for Load bearing members and 1.6 mm thick for non-load bearing members, complete
with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar
of adequate cross section through out the length of the panel. The incoming and outgoing
feeders shall be accommodated in a fully segregated, modular multitier arrangement with
adequate size and distinct cable alley, bus bar alley,. The panel shall be complete with name
plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings.
The panel shall withstand the fault level of as indicated elsewhere or shown in Single Line
Important Notes: Common for all Switchboard:
The BOQ shall be read inconjunction with general notes, specification and Single Line Diagram
(attached for Ref.). Incase of any discrepancy between specification, BOQ and SLD, the same shall
be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent
condition shall be deemed to have been considered.
Fault current wherever mentioned shall be Ics value. (Ics = 100% Icu).
All MCCB shall be provided with door interlocked rotary handle with ON/OFF/Trip indicating
All feeder doors shall have pad locking arrangement.
All TP feeders shall have solid isolable neutral link.
All MCCB used in starter feeder shall be suitable for motor duty application.
All Energy meters are digital type & with RS-485 port for communication.
Panel shall be powder coated of approved shade with minimum 60 micron thickness.
Size of Voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded
terminal shall be used in the panel.
Bus bar chamber shall be kept at top of the all panels.
All bus bar shall be insulated with coloured PVC Sleeve i.e.RYB,BK as per colour code.
Internal wiring of panel shall be with size 2.5sqmm Flexible Copper Conductor for CT circuit and
control wiring with 1.5 sqmm.
All indicating light shall be LED type .
Wherever only voltmeter & ammeter are required, the same may be provided in combined
meter suitable for both parameter.
Space heater shall be provided in each cable alley.
All switchgear used in starter feeder shall be type-2 co-ordinated. Vendor is required to submit
manufacturer's type-2 co-ordination chart for the make used.
All MCCB above 250A shall be with microprocessor based O/L, S/C and Earth fault releases.
All MCCB upto 250A shall be with thermal magnetic based O/L & S/C releases.
All CTs shall be cast Resin type and shall be privided with CT shorting links.
Current density of bus bar shall be less than 1A/Sqmm.
TTA panels AS PER IEC : 61439-1&2
Necessary Co-ordination shall be done by the Panel Manufacturer/ Vendor with the vendor of
"Gas flooding system" for fire protection, for making suitable provisions in the panels at the
Design stage, Manufacturing stage, stage of testing at works & stage of commissioning at site.
The Panel shall be provided with TVSS (SPDs). Panel vendor/ Manufacturers shall Co-ordinate
with SPD Vendor for the suitable provision for the installation for the same (SPDs).
1nos.125 Amp,four pole Moulded Case Circuit Breaker (Ics = Icu = 25 KA) with thermal magnetic
based release with built in O/L & S/C release.
ASID CONSULTANTS 12/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Digital MF Meter( with Voltage, Current & Frequency) with selector switch and one set of 3 nos.
CTs of ratio 125/5A , Class I accuracy and 5 VA burden- 1set.
3 Nos.phase indicating LED lamps each with 2 amp back up MCB.
3 Nos. on/ off / Trip indicating LED lamps each with 2 amp back up MCB.
4P, al bus bars of minimum 150 Amps capacity with heat shrinkable coloured sleeves and i/c,
SMC bus bars supports at required intervals complete for cross section, size supports & their
spacing etc. for withstanding fault level of 25 KA for 1 sec.
2 nos.100 Amp, TPN Moulded Case Circuit Breaker (Ics = Icu = 25 KA) with thermal magnetic
based release with built in O/L & S/C release.
Digital MF Meter( with Voltage, Current & Frequency) with selector switch and one set of 3 nos.
CTs of ratio 100/5A , Class I accuracy and 10 VA burden- 1set.
3 Nos.phase indicating LED lamps each with 2 amp back up MCB.
3 Nos. on/ off / Trip indicating LED lamps each with 2 amp back up MCB.
3 nos.63 Amp, TPN Moulded Case Circuit Breaker (Ics = Icu = 25 KA) with thermal magnetic based
release with built in O/L & S/C release.
Digital MF Meter( with Voltage, Current & Frequency) with selector switch and one set of 3 nos.
CTs of ratio 100/5A , Class I accuracy and 10 VA burden- 1set.
3 Nos.phase indicating LED lamps each with 2 amp back up MCB.
3 Nos. on/ off / Trip indicating LED lamps each with 2 amp back up MCB.
3 Nos. 63 Amp, 4P MCB (Ics = Icu = 10 KA).
3 Nos. 40 Amp, DP MCB (Ics = Icu = 10 KA).
EL-NS 17.1 SDB LIGHT & POWER PANEL as described above Nos. 2 225209.00 450418
EL-NS 17.2 Supply, loading, Unloading, Receiving, Installation, Testing and commissioning 32 Amp,double
pole MCB (10 KA) with powder coated enclosure.
TOTAL 0 455394
92 2025 DSR 6.0 LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,
2025 DSR 6.1 having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. Each 16 609.00 9744.00
complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning
conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning
conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4
2025 DSR 6.1 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.. Each 16 140.00 2240.00
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
12.60 Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other
equipments backfill compound which is non-corrosive, thermally conductive, potential
93 to permissible limits, superior Fault conduction capacity, non toxic, weather resistance &
capable of achieving ohmic value less than one ohm
12.60.6 Using 10ft. SS rod with backfill compound 1 kit 16 7351.40 117622.4
FIRE ALARM SYSTEM
94 Supplying, installation, testing and commissioning of micro processor based intelligent
addressable main fire alarm panel, central processing unit with the following loop modules and
capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors
per loop and loop length up to 2 km, network communication card, minimum 320 character
graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in
the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24
28.2.1 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to
connect printer to printout log and facility to have seamless integration with analog/digital voice
evacuation system (which is part of the schedule of work under SH: PA System) and shall be
complete with all accessories . The panel shall be compatible for IBMS system with open protocol
BACnet/ Modbus over IP complete as per specifications.
95 Supplying, installation, testing & commissioning of addressable beam detector with short circuit
28.2.12 isolator (inbuilt or separate) complete with emitter and receiver including connections with Each 10 92659.50 926595
remote test features etc complete as required.
96 Supplying, installation, testing & commissioning of addressable manual call point complete as
97 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as
28.5 CABLING & WIRING
98 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed
28.5.2 copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as Metre 2496 226.56 565493.76
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the
28.5.3 existing surface / recessed steel conduit of following pairs, cores and size including connections
and interconnections etc. as required.
CCTV SYSTEM (IP BASED)
5MP /6MP IP IR Bullet Camera
Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having
following specifications, type of lens and features etc :-
1) Type of Camera: Bullet Camera
2) Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition
3) Signal System: PAL/NTSC
4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better
ASID CONSULTANTS 13/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation,
Multi zone Privacy Masking, HLC, Digital Watermarking.
6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video
7) Signal to Noise Ratio: > 50 dB
8) Lens Type & Focus: as given below.
9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR
Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 Mtrs for colour
10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC,
11) Wide Dynamic Range: WDR (120dB or more)
12) Digital Noise Reduction: DNR (2D/3D) On/Off
13) Streaming: Triple streaming, configurable
14) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5MP/6MP
@25/30 fps, Sub streams: D1@25/30 fps or better
15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through
client software or web browser
16) Profile Management: User configuration import, export
17) Security: User Authentication, Digital Water Marking
18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512
GB. It should be supplied with minimum 128GB memory Card.
19) Recording Management: Format SD, overwrite, storage management, video to NAS device,
20) Edge Analytics: Tripwire, Intrusion, Motion Detection
21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict
detection; memory card state detection; memory space detection
22) Alarm Support: It should have 1/1 Alarm In/ Out Port
23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and
Speaker (As per site requirement) with G.711U/A / G.711Mu/ AAC/ G.726 audio compreesion
24) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,
NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
25) System Capability: ONVIF
26) VMS: Camera shall support open source VMS
27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted
execution, Digest, security logs, account lockout, , video encryption, IP/MAC filtering, HTTPS,
28) Ethernet: 1 RJ 45 10/100 Ethernet port
29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power
adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.
30) Power Requirement: 12VDC/24V DC/PoE (802.3af)/ePoE
31) Enclosure: IP67 weather proof, IK10
32) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-
33) IR life: 40000 hours or higher
34) Video Bit rate: 32 KBPS - 8 MBPS or better
35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
5MP/6MP IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet
PTZ (Pan. Tilt and Zoom) IP IR Camera
Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having
following spcifications and features etc :-
PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :-
1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR
2) Image Sensor: 1/2.8" or better progressive Scan CMOS
3)Signal System: PAL/NTSC
4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR, or better
5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation,
Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and
6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video
7) Signal to Noise Ratio: > 50 dB
8) Event Notification: Through Relays, E-Mails or FTP
9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR
Source- Inbuilt IR LED's with effective distance. The camera should have IR LED’s and cover
distance up to 300 meter or above
10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking
function using simultaneously all of the panning, tilting and zooming should be available. When a
motion is detected in a registered monitoring area, the camera should track the motion (object)
and capture it.
11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event
12) Presets: 300 Presets
13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726,
14) Wide Dynamic Range: WDR (120dB or more), HLC & BLC
15) Digital Noise Reduction: DNR (2D+3D) On/Off
16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness
adjustable through client software or web browser
17) Profile Management: User configuration import, export
18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout,
video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution
19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512
GB . It should be supplied with minimum 128GB Memory.
20) Recording Management: Format SD, overwrite, storage management, video to NAS device,
remote archive access via FTP login
21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network
disconnection detection; IP conflict detection; memory card state detection; memory space
detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection
ASID CONSULTANTS 14/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP,
DHCP, SMTP, RTSPS.
23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of
ONVIF and quoted models should be listed on ONVIF official website (All the certifications &
Credentials should be valid on the date of technical evaluation).
24) VMS: Camera shall support open source VMS
25) Connectivity: 1x LAN RJ-45 (10/100Base-T)
26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect
External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2,
27) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out
28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power
adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one
29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at)
30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning
proof, surge protection, voltage transient protection
31) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-
32) IR life: 40000 hours or higher
33) Video Bit rate: 32 KBPS - 8 MBPS or better
34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
5MP IP IR motorized PTZ @25/30fps or better camera, Triple streaming , configurable on
Main stream: 5MP@25/30 fps Sub streams:1080p@25/30 fps, varifocal lens 3.95mm
100 DSR 2025 40.9.3 (±5mm) ~ 177.75mm (±5mm) or better with Automatic & manual Focus Adjustment provisions, Nos. 8 107974.00 863792.00
45x Optical zoom and 16x Digital zoom with angle of view H: 65.7°–1.9°V: 39.4°–1.1°D: 73.1°–2.1,
PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset :
300° /s, Tilt Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s
Network Video Recorder (NVR)
101 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder
DSR 2025 40.11 (NVR) with camera licenses to record for all channels having specifications and features etc as
mentioned below :
1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record
per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP
camera or more and must be ONVIF with minimum support of 384 Mbps
incoming Bandwidth.
2) NVR should support video compressions : H.265 or better, H.264, MJPEG.
3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A,
G.711u, PCM, G726 audio compressions.
4) Intelligent auto power on when power resumes after power outage.
5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of
6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x
7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
8) Video Output Ports: 2x HDMI and 2 VGA
9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors
and output devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile
number for power failure, HDD failure, vandalism, tempring, network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE,
FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S,
CGI, SDK and OEM Cloud for remote monitoring without any public IP need.
13) Standards: CE, FCC, RoHS, BIS Certified
14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.
15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)
16) The VMS application shall support all the features & functionalities of the offered cameras.
17) VMS should consist Licenses for all channels to record Cameras with General, motion
detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera
Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras
to achieve the functionality.
18) The NVR OEM shall be responsible for providing a mobile application compatible with both
Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.
19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public
IP address for remote monitoring over the Internet.
20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode
21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1;
22) When alarm recording is enabled and an event occurs, you can click the alarm icon on
monitoring page to view the alert details. The snapshot function is supported on monitoring and
23) The Network Video Recorder (NVR) shall be configured to send email whenever a system
message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each
recipient email address shall be configured to receive any combination of critical, warning, or
informational messages or alarm notifications. When an alarm occurs, the email message
includes the NVR name,
time of alarm and a list of camera that is configured to record upon alarm
24) It should have Web and GUI interface.
25) Built-In Artificial Intelligence: NVR should have built-in AI :-
- 2 Channel face detection and recognition, - Minimum
4 Channel perimeter protection, - Minimum 8 Channel
Smart Motion Detection
26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of
Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to
add Name, gender, birthday, address, credential type, credential
No., countries & regions and state to each face image.
ASID CONSULTANTS 15/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses,
expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.
28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body,
vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.
29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing,
PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection
(intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map,
Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception
30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm
output, buzzer, logs, presets and email.
31) General AI Based Search: Search Pictures by channel, time, event type, target classification
(Fall Detection, People Approach Detection, People No. Exception Detection, People Staying
Detection, Violence Detection.
32) Smart playback function: Should support smart search for the selected area in the video and
smart playback to improve the playback efficiency
33) VCA (Video Content Analytic): Should support multiple video contented analytics based on
camera analytics
34) Analytics by NVR: Perimeter protection and face recognation
32 Channel Network Video Recorder (NVR) having display split :- Main screen:
Hard Disk Drive
102 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard
Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form
factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-
Scheme, TUV, UL Certifications.
Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor)
industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast
connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode
DSR 2025 42.4 should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response
time less than 12ms, Display control shall be on monitor screen and programmable with remote
(remote shall be supplied with system),
Key Board, Optical Mouse, etc. as required.
Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with
Main Frame Pillar of 1.25mm Powder Coated CRCA Sheet with removable side panels, L- Shape
adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition
(CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit
DSR 2025 -39.24 provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS Nos. 2 21201.00 42402.00
frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL-
7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers
closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as
Fiber Backbone-2Runs x 6core Fiber Cable,OM3 MM
105 Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel
armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-
buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm,
bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications:
ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall
be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-
DSR 2025 -39.20 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium
Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should
be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation
± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength
1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The
value for Mode-filed,Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing &
marking etc complete as required.
DSR 2025 -39.20.1 6 Core Multi Mode Optical Fiber Cable RM 300 87 26100.00
ASID CONSULTANTS 16/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
Part F PLUMBING WORK SUMMARY
SL.NO. DESCRIPTION PWD AMOUNT NS ITEMS AMOUNT
1 SUB HEAD I : SANITARY INSTALLATIONS 170517.32 45610.00
2 SUB HEAD II : WATER SUPPLY 788559.78 0.00
3 SUB HEAD III : DRAINAGE 1359367.08 2575000.00
Grand Total 4939054.18
Grand Total 4939054.18
ASID CONSULTANTS 17/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
KPWD NS Items KPWD /DSR NS Items
SR. NO. DESCRIPTION OF ITEMS UNIT Qty Rate with CF
2023/2024 Rates Amount Amount
Part F1 PLUMBING WORK
SH I : SANITARY INSTALLATIONS
106 14.1 Providing and fixing water closet squatting pan
(Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre
low level white
P.V.C. flushing cistern, including flush pipe,
with manually controlled
device (handle lever) conforming to IS : 7231,
with all fittings and fixtures
complete, including cutting and making good
the walls and floors wherever
14.1.1 White Vitreous china Orissa pattern W.C. pan
of size 580x440 mm with Each 2 5763.1 11526.2
integral type foot rests
107 14.2 Providing and fixing white vitreous china
pedestal type water closet
(European type W.C. pan) with seat and lid, 10
litre low level white P.V.C.
flushing cistern, including flush pipe, with
manually controlled device
(handle lever), conforming to IS : 7231, with all
fittings and fixtures
complete, including cutting and making good
the walls and floors wherever
14.2.1 W.C. pan with ISI marked white solid plastic
seat and lid Each 4 5708.8 22835.4
108 14.4 Providing and fixing white vitreous china flat
back or wall corner type
lipped front urinal basin of 430x260x350 mm
and 340x410x265 mm
sizes respectively with automatic flushing
cistern with standard flush
pipe and C.P. brass spreaders with brass
unions and G.I clamps complete,
including painting of fittings and brackets,
cutting and making good the
walls and floors wherever required :
14.4.1 One urinal basin with 5 litre white P.V.C.
automatic flushing cistern Each 5 5255.7 26278.6
109 14.7 Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
C.P. brass waste of standard pattern, including
fittings and brackets, cutting and making good
the walls wherever require:
14.7.1 White Vitreous China Wash basin size
630x450 mm with a pair of 15 mmC.P. brass Each 6 3636.8 21820.6
110 14.22 Providing and fixing G.I. inlet connection for
flush pipe connecting with W.C. pan. Each 4 135.7 542.8
14.22.A Providing and fixing CP Brass 32mm size
Bottle Trap of approved quality& make and as Each 6 955.8 5734.8
per the direction of Engineer-in-charge.
111 14.28 Providing and fixing P.V.C waste pipe for sink
or wash basin including P.V.C waste fitting
14.28.1 Semi rigid pipe
ASID CONSULTANTS 18/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
KPWD NS Items KPWD /DSR NS Items
SR. NO. DESCRIPTION OF ITEMS UNIT Qty Rate with CF
2023/2024 Rates Amount Amount
112 14.32 Providing and fixing mirror of superior glass (of
approved quality) and of required shape & size
with plastic moulded frame of approved make &
shade with 6mm thick hard board backing.
14. 32.2 Rectangular shape 453 X 357 mm Each 6.00 1201.2 7207.4
113 14.34 Providing and fixing toilet paper holder. CP
114 14.74 Providing and fixing Single lever Bib cock Long
Nose (Lifting type
cold water cartridge) with wall flange made of
Stainless steel with all concealed fitting
arrangements & all necessary accesories
complete - Class
a) 15 mm nominal bore. Each 10.00 1475.0 14750.0
115 17.61 Cutting chases in brick mansonry walls for
following diameter sand cast (spun) iron pipes
and making good the same with cement
concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 12.5mm nominal size),
incliding necessary plaster and pointing in
cement mortal 1:4 (1 cement :4 coarse sand):
116 14.92 Providing and fixing Soap dish wired with
200mm width made of Stainless
steel with all concealed fitting arrangements &
all necessary accesories
complete - Class
117 F1-NS 18 Providing, fixing, jointing and testing in position
of ISI marked UV stabilized UPVC pipes for
soil, waste and vent, Type-B as per IS : 13592
suitable for rubber ring joints, including all
neccessary specials and fittings (confirming to
IS:14735) i.e. bends, tees, junctions (with or
without doors), reducers, WC connectors,
couplers, cowels, clamps, rubber rings, clean
outs etc. fixing at wall/ ceiling/ floor level
supported by clamp & hangers etc. in
concealed / inside duct / under floor &
basement ceiling / external work etc. including
chase cutting as required, excavation and back
filling in all kind of soils, suspended from floor
under false ceiling or embedding the pipes laid
under floors / building in 75 mm. alround 1:2:4
cement concrete (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size)
including cost of shuttering for proper
completion of the work, breaking and making
good the walls and floors etc. after pipes have
been duly laid and tested. The rubber ring shall
confirm to IS:5382.
The Pipes will be supported with threaded G I
rods & clamps on 50x50x5 mm slotted angle.
The cost will include all support arrangements.
The work includes commissioning of all pipes
lines as per drawings and specifications and as
directed by engg-in-charge at site.
F1-NS 18.1 110mm outer dia Metre 5.00 1400.0 7000.0
ASID CONSULTANTS 19/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
KPWD NS Items KPWD /DSR NS Items
SR. NO. DESCRIPTION OF ITEMS UNIT Qty Rate with CF
2023/2024 Rates Amount Amount
118 F1-NS 19 Providing, fixing, jointing and testing in position
ISI marked (IS:4985) UPVC pipes of min 6 Kg/
Sqcm rating with fitting for waste pipe from
fixtures to floor trap including reduces,
enlarger, socket, couplers, bends, tees etc
including fixing at wall/ ceiling level supported
by clamp & hangers etc. cutting holes in wall/
floors/ slabs and making good the same with
cement concrete 1:2:4 complete as required.
F1-NS 19.1 40mm outer dia Metre 25.00 400.0 10000.0
F1-NS 19.2 50mm outer dia Metre 10.00 490.0 4900.0
119 F1-NS 20 Providing & fixing UPVC Floor trap of self
cleansing design with CP Jali complete in all
F1-NS 20.1 a) 100 mm inlet and 100 mm outlet.
( with 127dia Glossy CP Grating Each 10 891.0 8910.0
120 F1-NS 21 Providing & fixing 110m x 50mm waste with
PVC reducer including cutting chases in floor,
cutting RCC slab complete as required.
121 F1-NS 22 Providing & fixing Health Faucet with 8mm dia,
1M long PVC tube and wall hook. Approved 2600.0 10400.0
122 F1-NS 23 Providing & fixing wall mounted 35 mm
dia.,600mm long grab bar including cutting &
making good the walls.approved equal make.
Sub-Total of Sanitary Installation, Separate
for Scheduled & Non-Scheduled Items 170517.3 45610.0
SH II : WATER SUPPLY
123 13.31 Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes,
having thermal stability for hot & cold water
supply, including all CPVC
plain & brass threaded fittings, including fixing
the pipe with clamps at
1.00 m spacing. This includes jointing of pipes
& fittings with one step
CPVC solvent cement and testing of joints
complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall
Internal Work - Exposed on Wall
13.31.1 15 mm nominal dia pipes. Metre 2.00 214.8 429.5
13.31.2 20 mm nominal dia pipes. Metre 2.00 285.6 571.1
13.31.3 25 mm nominal dia pipes. Metre 15.00 375.2 5628.6
13.31.4 32 mm nominal dia pipes. Metre 10.00 472.0 4720.0
13.31.5 40 mm nominal dia pipes. Metre 10.00 632.5 6324.8
124 13.32 Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes,
having thermal stability for hot & cold water
supply, including all CPVC
plain & brass threaded fittings, i/c fixing the
pipe with clamps at 1.00
m spacing. This includes jointing of pipes &
fittings with one step CPVC
solvent cement and the cost of cutting chases
and making good the
same including testing of joints complete as per
direction of Engineer in
Charge. Concealed work, including cutting
chases and making good the
13.32.1 15 mm nominal dia pipes. Metre 2.00 364.6 729.2
ASID CONSULTANTS 20/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
KPWD NS Items KPWD /DSR NS Items
SR. NO. DESCRIPTION OF ITEMS UNIT Qty Rate with CF
2023/2024 Rates Amount Amount
13.32.2 20 mm nominal dia pipes. Metre 30.00 447.2 13416.6
13.32.3 25 mm nominal dia pipes. Metre 20.00 562.9 11257.2
13.32.4 32 mm nominal dia pipes. Metre 15.00 657.3 9858.9
Providing and laying Ductile Iron pipes of class
conforming to IS 8329:2000 with latest
amendments, conveying to work site, rolling
and lowering into trenches, laying true to line,
level and perfect linking at joints, testing and
commissioning, including loading and
unloading at both destinations, cutting of pipes
wherever necessary, jointing with DI specials
(excluding cost of specials) and rubber
gaskets, cleaning the socket and spigot end
with soap solution, applying soft soap to the
socket and spigot ends before insertion of
rubber gaskets, jacking and fixing in perfect
conditions etc. The cost to include soap
solution, soft soap, waste etc. and giving
necessary hydraulic test to the required
pressure as per ISS with all lead and lifts and
cost of all jointing materials. (The contractor will
make his own arrangements for water for
testing. Earth work excavation in trenches to be
measured and paid for seperately)
Note: In sewerage projects for internal cement
mortal lining ( CML ) of DI pipes, if High
Alumina Cement ( HAC ) as recommended in
Annexure B clause 16.3 of IS8329:2000 is
considered in place of Slag or Sulphate
Resistance Cement ( SRC ), the cost of pipes
may be increased by 5-6% from the prices
listed. For DI K7 pipes:
Ductile Iron Pipe Class K-7 100mm dia. Metre 500.00 1398.3 699150.0
126 13.33 Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes having thermal stability
for hot & cold water supply including all (CPVC)
plain & brass threaded fittings. This includes
jointing of pipes & fittings with one step CPVC
solvent cement,trenching,refilling and testing of
joints complete as per direction of engineer in
127 13.34 Providing and placing on terrace (at all floor
levels) polyethylene
water storage tank, IS : 12701 marked, with
cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow
pipes but without fittings and the base support
for tank. Per Litre 3000.00 10.6 31860.0
128 13.4 Providing and fixing gunmetal gate valve with
CI wheel of approved quality(screwed end).
13.4.2 32 mm dia nominal bore Each 2.00 705.6 1411.3
13.4.3 40 mm dia nominal bore Each 2.00 828.4 1656.7
129 13.5 Providing and fixing ball valve (brass) of
approved quality, High or low
pressure, with plastic floats complete :
13.5.2 20 mm dia nominal bore Each 1.00 370.5 370.5
13.5.3 25 mm dia nominal bore Each 3.00 391.8 1175.3
Sub-Total of Water Supply Installation,
Separate for Scheduled & Non-Scheduled 788559.8 0.0
SH III : DRAINAGE
ASID CONSULTANTS 21/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
KPWD NS Items KPWD /DSR NS Items
SR. NO. DESCRIPTION OF ITEMS UNIT Qty Rate with CF
2023/2024 Rates Amount Amount
130 13.49 Providing and fixing on wall face unplasticised
Rigid PVC rain water
pipes of 150mm dia conforming to IS : 13592
Type A, including jointing
with seal ring conforming to IS : 5382, leaving
10 mm gap for thermal
expansion, (i) Single socketed pipes.
a)150 mm diameter Metre 50.00 670.2 33512.0
131 13. 50 Providing and fixing Unplasticised Polyvinyl
Chloride (uPVC) pipes, for
cold water supply including all uPVC plain &
brass threaded fittings
This includes jointing of pipes & fittings with
one step uPVC solvent
cement, trenching, refilling & testing of joints
complete as per direction
of Engineer in Charge. External work
13. 50.6 50 mm nominal dia Pipes Metre 60.00 455.5 27328.8
13. 50.10 150 mm nominal dia Pipes Metre 360.00 1879.7 676706.4
132 13. 60 Providing and fixing PVC (S.W.R) P Trap
10cms x 10cms with all fitting
arrangements & all necessary accessories
133 13. 64 Providing and fixing Sewer (SWR) pipes,
including all fittings, This
includes jointing of pipes & fittings with one
step solvent cement,
trenching, refilling & testing of joints complete
as per direction of.
13. 64.2 Engineernominal
110mm in Charge.dia pipes Metre 60.00 454.3 27258.0
134 13.52 Constructing brick masonry manhole in cement
mortar 1:4 ( 1 cement
: 4 coarse sand ) with R.C.C. top slab with
1:1.5:3 mix (1 cement : 1.5
coarse sand (zone-III) : 3 graded stone
aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4
coarse sand : 8 graded stone
aggregate 40 mm nominal size), inside
plastering 12 mm thick with
cement mortar 1:3 (1 cement : 3 coarse sand)
finished with floating coat
of neat cement and making channels in cement
concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) finished
with a floating coat of neat cement complete as
per standard design :
Inside size 90x80 cm and 45 cm deep including
C.I. cover with frame (light
duty) 455x610 mm internal dimensions, total
weight of cover and frame
to be not less than 38 kg (weight of cover 23 kg
and weight of frame 15 kg)
With common burnt clay (non modular) bricks
of class designation 3.5 6.00 12467.9 74807.3
13.52.1 Extra for depth for manholes : Size 90x80 cm
With common burnt clay
(non modular) bricks of class designation 1.00 10898.5 10898.5
ASID CONSULTANTS 22/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
KPWD NS Items KPWD /DSR NS Items
SR. NO. DESCRIPTION OF ITEMS UNIT Qty Rate with CF
2023/2024 Rates Amount Amount
135 13. 40 Providing and fixing square-mouth S.W. gully
trap class SP-1 complete
with C.I. grating brick masonry chamber with
water tight C.I. cover 180
x 150 mm size P type & With Non Modular
common burnt clay bricks
of designation 3.5 & frame of 300 x300 mm
size (inside) the weight of
cover to be not less than 4.50 kg and frame to
be not less than 2.70 kg as
per standard design: Each 1.00 3169.5 3169.5
13. 55 Constructing brick masonry chamber for
underground C.I. inspection
chamber and bends with bricks in cement
mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty)
600X850 mm internal
dimensions, total weight of cover with frame to
be not less than 38
kg (weight of cover 23 kg and weight of frame
15 kg), R.C.C. top slab
with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3
graded stone aggregate 20
mm nominal size), foundation concrete 1:5:10
(1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal
size), inside plastering 12
mm thick with cement mortar 1:3 (1 cement : 3
coarse sand), finished
smooth with a floating coat of neat cement on
walls and bed concrete etc.
complete as per standard design: Inside
dimensions 600x 850 mm and
45 cm deep for pipe line with three or more
inlets : With common burnt
clay (non modular) bricks of class designation
136 F1-NS 24 Providing fixing, jointing and testing in
position the following UPVC pipes (working
pressure 6kg/sqcm) conforming to IS: 4985 for
drainage cut to required lengths including all
necessary fittings and specials such as
bends, junctions, offsets, making proper
connections. Including providing PCC thrust
block at 2 mtr. centre to centre. Pipe to be
laid below ground level in trenches upto
required depth including excavation in all kind
of soil, dewatering, refilling, watering, ramming
& removing the surplus excavated material and
making good the same complete as
required.For external sewer.
F1-NS 24.1 160mm outer dia Metre 50.00 2000.0 100000.0
F1-NS 24.2 250mm outer dia Metre 900.00 2750.0 2475000.0
Sub-Total of Drainage Installation, Separate
for Scheduled & Non-Scheduled Items 1359367.1 2575000.0
ASID CONSULTANTS 23/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
S.No. DESCRIPTION OF SUBHEAD PWD DSR / E&M - Amount NS Items Amount
1 SUB HEAD-A (PIPING & VALVES) 88,27,555.00 0.00
2 SUB HEAD-B (FIRE HYDRANT ACCESSORIES) 19,70,068.00 90,600.00
3 SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS) 0.00 3,40,908.00
Grand Total 11229131.00
Grand Total 11229131.00
ASID CONSULTANTS 24/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
Sl. No. DSR E&M-2025 / NS Items DESCRIPTION UNIT QTY. KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items Amount
Part G1 Fire Fighting Works
A SUB HEAD-A (PIPING & VALVES)
137 27.6 Providing, laying, testing and commissioning of 'C' class
heavy duty MS pipe conforming to IS 1239/3529 i/c fittings
like elbows, tee, flanges tapers, nuts bolts, gaskets etc. in
ground including welding, excavation and providing cement
concrete blocks as supports, anticorrosive treatment with
coaltar/asphalt tape as per IS 10221, refilling the trench etc.
of following sizes. complete as required.
138 27.7 Providing, laying, testing & commissioning of 'C' class heavy
duty MS pipe conforming to IS 3589/IS 1239 including
Welding, fittings like elbows, tees, flanges ,tapers, nuts
bolts, gaskets etc. and fixing the pipe on the wall/ceiling with
suitable clamp/support frame and painting with two or more
coats of synthetic enamel paint of required shade complete
27.7.9 200 mm dia ( wall thickness 6.3mm) RM 5 6620.00 33,100.00
27.7.10 250 mm dia ( wall thickness 6.3mm) RM 5 8023.00 40,115.00
139 27.14 Providing, installation, testing and commissioning of non-
return valve of following sizes confirming to IS:5312
complete with rubber gasket, GI bolts, nuts,washers etc.as
140 27.11 Supplying, fixing, testing and commissioning of butterfly
valve of PN 1.6 rating with bronze/gunmetal seat duly ISI
marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required :
141 30.8 (HVAC) Providing and fixing in position industrial type pressure
gauges with gun metal / brass valves complete etc. as
required. Nos 8 24.00 192.00
142 27.22 Providing & fixing of pressure switch in M.S. pipe line
including connection etc. as required. Each 4 1670.00 6,680.00
TOTAL SUB HEAD-A (PIPING & VALVES) C/F TO
B. SUB HEAD-B (FIRE HYDRANT ACCESSORIES)
143 27.9 Supplying and fixing single headed internal hydrant valve
with instantaneous Gunmetal/Stainless Steel coupling of 63
mm dia with cast iron wheel ISI marked conforming to IS
5290 (Type -A) with blank Gunmetal/Stainless Steel cap and
chain as required :
27.9.1 Single headed Gunmetal set 12 8208.00 98,496.00
144 27. 10 Supplying and fixing single headed external yard hydrant
valve with 1 nos 63mm dia instantaneous FM
Gunmetal/Stainless Steel coupling of 63 mm dia with cast
iron wheel ISI marked conforming to IS 5290 ( Type-A) with
blank Gunmetal/Stainless steel Cap and chain as required:
27. 10.1 Single headed Gunmetal Set 24 8208.00 1,96,992.00
145 27.17 Supplying and fixing first-aid Hose Reel with MS
construction spray painted in post office red, conforming to
IS 884 complete with the following as required. 20 mm
nominal internal dia water hose thermoplastic (Textile
reinforced) type -2 as per IS: 12585 20 mm nominal internal
dia gun metal globe valve &
nozzle. Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve
& M.S. Pipe and socket.
146 27.16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe
with 63 mm dia male and female couplings duly bound with
GI wire, rivets etc. conforming to IS 636 (type-A) as required
ASID CONSULTANTS 25/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Sl. No. DSR E&M-2025 / NS Items DESCRIPTION UNIT QTY. KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items Amount
147 27.18 Supplying & fixing 63 mm dia gun metal short branch pipe
with 20 mm nominal internal diameter size nozzle
conforming to IS 903 suitable for instantaneous connection
to interconnect hose pipe coupling as required :
148 G1-NS 25 Providing and fixing door with frame for all internal fire
hydrants fabricated from 20x20x3 mm and 40x20x3 mm
aluminium hollow box sections mounted with 3 no. of 100
mm Aluminium butt hinge on Aluminium angle frame of
45x45x5 mm size with hold fasts fixed to wall with P.C.C.
(1:2:4) blocks 100x100x100 mm including 2 nos allen key
lock for locking along with padlock arrangement & fully
glazed with 4 mm thick float glass approved by local Fire
Authority, powder coated fire red finish with " fire hose' Nos 12 7550.00 90,600.00
written on front suitable to house 15 mm long two length of
canvas hose with couplings, one no of branch pipe, one fire
mans axe and two numbers of portable extinguishers, first
aid fire hose and supports for hoses, branch pipes, Axe and
hose reel. Size 2100x 900 mm complete as per approved
design including necessary fixing arrangement for hoses &
axe and branch pipe.)
149 27.19 Supplying and fixing of fire brigade connection of cast iron
body with gun metal male instantaneous inlet couplings
complete with cap and chain as reqd. for suitable dia MS
pipe connection conforming to IS 904 as required:
150 27. 20 Supplying and fixing air vessel made of 250 mm dia, 8 mm
thick MS sheet, 1200 mm in height with air relase valve on
top and flange connection to riser, drain arrangement with
25 mm dia gun metal wheel valve with required accessories,
pressure gauge and painting with synthetic enamel paint of
approved shade as required:
151 27.21 Providing, fixing, testing & commissioning of 15mm dia
quartzoid bulb type sprinklers of rating 68 degree
centigrade with required accessories:
27.21.2 Upright Sprinkler Each 900 599.00 5,39,100.00
27.21.3 Horizontal side wall Sprinkler Each 200 699.00 1,39,800.00
152 27.24 Providing, fixing, testing and commissioning of installation
control valve of cast iron body, brass/bronze working parts
comprising of water motor alarm, bronze seat clapper,
clapper arm and hyraulically driven mechanical gong bell
sound continuous alarm when the wet riser/sprinkler system
activates, pressure gauge, emergency release, strainer,
pressur switch, cock valve complete with drain valve and
bypass, test control box, ball valve, MS pipe of required
size, flange, orifice plate,gasket etc of following size as
TOTAL SUB HEAD-B (FIRE HYDRANT ACCESSORIES)
ASID CONSULTANTS 26/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Sl. No. DSR E&M-2025 / NS Items DESCRIPTION UNIT QTY. KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items Amount
SUB HEAD-C (FIRE EXTINGUISHERS & MISC. ITEMS)
153 G1-NS 26 Providing and fixing standard firemans axe with heavy
rubber handle. Nos 36 1,053.00 37,908.00
154 G1-NS 27 Providing and fixing weather proof cabinet of size not less than
0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm
thick having central opening and 4 mm thick glazed glass doors
(Two nos.) suitably marked on the outside 'with the letters
"FIRE HOSE" including necessary locking arrangement and
painting in red colour suitable to accomodate, external yard
hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle
and fire man's axe. It shall be mounted on boundary wall
complete as required. Set 24 12625.00 3,03,000.00
TOTAL SUB HEAD-G1 (FIRE EXTINGUISHERS & MISC.
ITEMS) C/F TO SUMMARY
ASID CONSULTANTS 27/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
Sl. No. DSR Code (2025) DESCRIPTION UNIT QTY KPWD Rate/DSR NS Items KPWD /DSR NS Items
/ NS Items Rate Rates Amount Amount
Part I Landscape Works
155 DSR Code Providing and laying 60 mm thick faciory made cement concrete Sqm 646.75 1,108.08 7,16,647.04
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size,
16.68 design & shape, laid in required colour and pattern over and
including 50 mm thick compacted bed of coarse sand, filling the
156 DSR Horticulture Plantation of Trees, Shrubs, Hedge, ground covers and
& Landscaping seasonal plantsat site i/c watering and removal of
2025 unsaverieable material’s as perdirection of officer in charge
2.57 (excluding cost of plant & water)
2.57.1 Trees plantEach9.452.57.2 Each 100 9.45 945.00
2.57.2 Shrubs PlantEach4.702.57.3 Each 300 4.70 1,410.00
2.57.3 Hedge Plant/ Ground Cover Plants /Seasonal Plants Each 900 3.15 2,835.00
TOTAL -PART I 7,21,837 -
ASID CONSULTANTS 28/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
KPWD item Code/ NS KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items
Sl. No. Description of Item Unit Quantity
Item with CF @0.973 Rates Amount Amount
Part J Structure Works for Road works
Surface dressing of the ground including removing vegetation and inequalities
157 not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up
Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
158 excavated surfaces, disposing off or levelling the excavated earth or sorting &
stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m
including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the Work
In all kinds of soils Depth upto 3 m Cum 13,191.00 120.36 15,87,668.76
Preparation and consolidation of sub grade with power road roller of 8 to 12
tonne capacity after excavating earth to an average of 22.5 cm depth, dressing
159 to camber and consolidating with road roller including making good the Sqm 12,445.00 212.99 26,50,656.82
undulations etc. and re-rolling the sub grade and disposal of surplus earthwith
lead upto 50 metres.
Construction of Subgrade and Earthen Shoulders
Construction of sub-grade and earthen shoulders with approved material
160 obtained from borrow pits with all lifts & leads, transporting to site, spreading, Cum 3,734.00 581.74 21,72,217.16
grading to required slope and compacted to meet requirement of table No.
Granular Sub-Base
Plant Mix Method
Construction of Granular Sub-Base of required grading as per design mixing in
161 a mechanical mix plant at OMC, carriage of mixed Material to work site,
spreading in uniform layers with motor grader on prepared surface and
compacting with vibratory power roller to achieve the desired density,
complete as per clause 401
(v) For Grading -V Material Cum 3,734.00 2,934.66 1,09,58,020.44
Dry Lean Cement Concrete Sub-base
Construction of dry lean cement concrete Sub- base over a prepared sub-
grade with coarse and fine aggregate conforming to IS: 383, the size of coarse
aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1,
162 aggregate gradation after blending to be as per table 600-1, cement content Cum 1,867.00 5,805.60 1,08,39,055.20
not to be less than 140 kg/ m3 , optimum moisture content to be determined
during trial length construction, concrete strength not to be less than 7 Mpa at
7 days, mixed in a batching plant, transported to site, laid with a paver with
electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
Pavement Quality Concrete using paver - M40 Grade Construction of M40
Grade un-reinforced, dowel jointed, plain cement concrete pavement over a
prepared sub base in recommended proportions, coarse and fine aggregate
conforming to IS 383:2016, maximum size of coarse aggregate not exceeding
25 mm, mixed in a batching and mixing plant as per approved mix design
163 transported to site, laid with a slip form paver finisher, spread, compacted and
finished in a continuous operation including provision of contraction,
expansion, construction and longitudinal joints, joint filler, separation
membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod,
admixtures, curing compound, steel channels, finishing to lines and grades as
164 DSR Code Providing and laying at or near ground level factory made kerb stone of M-25 CUM 55.00 11,289.20 6,20,905.86
grade cement concrete in position to the required line, level and curvature,
jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making
16.69 joints with or without grooves (thickness of joints except at sharp curve shall
not to more than 5 mm), including making drainage opening wherever
required complete etc. as per direction of Engineerin-charge (length of
finished kerb edging shall be measured to calculate volume for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-charge).
165 DSR Code Providing and laying 60 mm thick faciory made cement concrete interlocking Sqm 4734.00 1,078.16 51,04,018.15
paver block of M -30 grade made by block making machine with strong
vibratory compaction, of approved size, design & shape, laid in required colour
16.68 and pattern over and including 50 mm thick compacted bed of coarse sand,
filling the joints with line sand etc. all complete as per the direction of
SUB TOTAL 7,55,95,723 0
ASID CONSULTANTS 29/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
DSR item Code/ KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items
Sl. No. Description of Item UNIT QTY
NS Item with CF @0.973 Rates Amount Amount
Part K Road Painting Works:
166 DSR Code Painting road surface marking with adequate nos of coats to give Sqm 2746.20 320.45 8,80,030
uniform finish with ready mixed road marking paint conforming to
IS : 164, on bituminous surface in white/yellow shade, including
16.48 cleaning the surface of all dirt, scales, oil, grease and foreign
material etc. complete.
16.48.1 New work (Two or more coats)
TOTAL -PART K 8,80,030 -
ASID CONSULTANTS 30/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
DSR item Code/ NS Items KPWD /DSR NS Items
Sl. No. Description of Item UNIT QTY Rate with CF
NS Item Rates Amount Amount
Part L Mechanical ventilation Works
167.0 L-NS 28 PROPELLER FANS
Supplying, installing, testing and commissioning of direct driven PROPELLER FANS for
fresh/ exhaust air as shown in drawings. Housing shall be constructed of 18 gauge heavy MS steel
sheet spray galvanized. Fan motor shall be suitable for 415 + 8% volts, 50hz, 3 phase power
supply,Motor RPM shall not exceed 1500 RPM. Each fan shall be complete with permanent split
capacitor or shaded pole motor, mounting plate, accessories like wire guard, bird screen and fixed
louvers for weather protection as required. Fan selection arrangement and Electrical characteristics
shall be as follows :
L-NS 1.1 FRESH AIR - 900 mm dia 720 RPM fan suitable for 440 volts, 1200 WATT, 16000 CFM Nos. 32 41590 1330880
L-NS 1.2 EXHAUST - 900 mm dia 720 RPM fan suitable for 440 volts, 1200 WATT, 16000 CFM Nos. 32 41590 1330880
168.0 L-NS 29 MAIN CONTROL PANELS- FRESH AIR & EXHAUST FANS
Design, Manufacture, Supplying, Transport to the site, Receiving, Unloading, Shifting to location,
handling, assembling, installation in correct aligned position, grouting with dash fasteners, GI nuts-
bolts, testing and commissioning of the following bolted fabricated in compartmentalized (Form-3B
construction) conform to IS: 8623/1993, Suitable for 415V, 3Phase, 4 Wire 50 Hz Ac supply, housed
in design form CRCA sheet steel of 2mm thick for frame work and door covers, 3mm thick for gland
plate, i/c cleaning & finishing complete, having extensible type bus bars of high conductivity, SMC
bus bar supports, the maunfacturer shall be certified from CPRI for short circuit withstand capacity
of min. 25 kA for 1 Sec., fabrication shall be done in transportable sections and all front and back
doors shall be hinged type and earth with frame, Entire panel shall have a common earth bar as
specified below at the rear with 2 Nos. earth stud each side, bus bars and control wiring with
suitable size of FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two
half, i/c providing following switch gears :-
The Bus bars will be electrolytic grade E91 Aluminium duly sleeved with Helogen Free heat shrink
coloured Insulated tube confirming to IEC 60684-3-247 Standard. The powder coating (70-80micron
as per IS:13871 for indoor and 100-120 micron for outdoor), include one size higher terminal block in
cable alley and interconnecting wires between bus bars and terminals via MCB.
All Panels shall be considered Indoor type unless specified.
The degree of protection for all indoor type panels shall be of IP:52 ("5" Indicates Dust Protected
limited ingress of dust permitted. Will not interefere with operation of the equipment and "2"
indicates protection against vertically falling drops of water with enclosure tilted upto 15 deg from
It is recommonded that only one make of switchgear to be used in a board / Panel.
The treatment of Panel Shall be Fully automatic 9-tank process for metal treatment which consists of
Solvent/ Alkaline Degreasing, Water Rinsing, De- Rusting, Water Rinsing, Passivation,
Phosphating, Water Rinsing, Activation and Drying
A separate compartment for Minimum 20% spare space of Panel shall be provided for outgoings in
future and busbars shall be drilled accordingly.
All incoming/outgoing MCB shall be mounted on din channel inside closed chambers shall have
Acrylic sheet infront and front door should be a glass for see thru.
Direct magnetic/ screwed mounting panel light of minimum 100 lux at terminal point shall be
provided in each relay, instrument and cable alley compartment and in all back accessible
compartments each with door toggle switch. Refer Finder 7L Series.
1. All Starters shall be High Performance Star Delta / DOL Motor Starters as specified (Type 2 Co-
ordination chart shall be followed of selected OEM but contactor shall be used one rating higher for
IE3 efficiency motors with MPCB/MCCB at 415 V).
Incomers –1 Nos x 100 Amps 4P MCCB thermal magnetic based of fault rating capacity 16 KA (Ics=
Icu) upto 415 volts manually operated & with in-built S/C, O/C protection relay, extended rotary
handle for door interlock, indication for breaker On/Off/Trip. Phase separater & phase barriers on
METERING & INDICATION
1 Set RYB phase indication LED lamps with 2 Amps backup MCB, Test Terminal Blocks set with
CT operated multi function panel mounted meter (96x96 mm) covering voltage, ampere, frequency,
power factor, KW, RS 485 port, MCB display with class 1 accuracy for incomer.
TVSS & BUSBARS SECTION
150 Amps Aluminium Bus Bar4P with heat shrinkable coloured sleeves I/C SMC bus bar cross
sections, side support & their spacing etc with withstanding fault level of 25 kA for 1 second.
1 No. surge protection device (type 2 class C), 4 mode, connected between each phase to neutral
and neutral to earth. Nominal discharhe current (8/20 us) 25 KA per phase SPD with 63 A
MCBincluding all necessary accessories.
16 Nos. x 16 Amps. 4P MCB to 16 nos. Fan Starters
Control Panels as described above Nos. 2 228186 456372
168.0 L-NS 30 Supplying, installation, testing and commissioning of GI construction fresh/exhaust air louvers
with bird screen painted in baked enamel shade with metallic frame work complete as
per specification approved drawings and schedules. Louvers need to be suitable in order SQM 25.12 10038 252155
to avoid rain water entry in to spaces @ 15 degree deflection with bird screen complete as
per technical specification
TOTAL FOR VENTILATION SYSTEM 3370287
ASID CONSULTANTS 31/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Proposed Construction of additional two Nos. of storage sheds inside wharf area at NMPA Mangaluru
Sl. No. KPWD item Code/ Description of Item Unit Quantity KPWD Rate/DSR Rate NS Items KPWD /DSR NS Items
NS Item with CF @0.973 Rates Amount Amount
Part M Toilet Block Structure Works
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per
drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,
169 including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting &
stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools,
usage of machinery & other appurtenaces required to complete the Work
In all kinds of soils Depth upto 3 m Cum 293.00 120.36 35,265.48
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other
170 similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming Cum 257.00 313.88 80,667.16
and watering, lead up to 50 m and lift upto 1.5 m
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The
granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes
171 machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all
Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Cum 14.00 7,067.02 98,938.28
Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub
structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The
granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes
172 machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing
weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the
requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications.
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum 32.00 7,476.48 2,39,247.36
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water
works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super
173 plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of
all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of
machinery, curing and all other appurtenances required to complete the work as per technical
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum 47.00 8,074.74 3,79,512.78
Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials,
174 machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with
binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating
continuous chemical barrier under and around the column pits, walls, trenches, basement, excavation,
top surface of the plinth filling, junction of wall and floor, along the external perimeter of building,
175 expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of Sqm 121.00 139.24 16,848.04
pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of
chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete
as per specifications.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation
KPWD Vol.2 and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour,
6.1 scaffolding and usage charges of machinery & other incidental charges complete as per the direction of
engineer incharge of work.
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in
KPWD Vol.2 superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
6.7 including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental
charges complete as per the direction of engineer incharge of work.
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in
KPWD Vol.2 superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand)
6.15 including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental
charges complete as per the direction of engineer incharge of work.
KPWD Vol.2 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry
KPWD Vol.2 including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
8.1.1 including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine
KPWD Vol.2 sand) including rounding off corners wherever required smooth rendering, providing and removing
8.2.1 scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge.
Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface /
KPWD Vol.2 ceilings including rounding off corners wherever required smooth rendering, providing and removing
8.10 scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge.
CPWD Centering and shuttering including strutting, propping etc. and removal
5.9 of form for
Foundations, footings, bases of columns, etc. for mass concrete Sqm 37.00 381.56 14,117.79
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Sqm 74.00 819.75 60,661.69
CPWD Suspended floors, roofs, landings, balconies and access platformSuspended floors, roofs, landings, Sqm 217.00 902.21 1,95,780.49
5.9.3 balconies and access platform
Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 95.00 935.34 88,857.77
SUB- TOTAL 22,30,215 0
ASID CONSULTANTS 32/32 NBCC INDIA
Digitally LIMITED
signed by DEEPAK
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
NIT F.pdf
Tender Document
NMPA_SHEDS_Tender Drawings.pdf
Tender Document
GCC for Construction Works 2026.pdf
Tender Document
SCC F.pdf
Tender Document
NMPA- SHED_Technical Specification Civil Structure.pdf
Tender Document
NMPA SHED Technical Specification for Electrical LV System.pdf
Tender Document
Soil Invest Report NMPT Mangalore.pdf
Tender Document
Approved Make List.pdf
Tender Document
Integrity Pact NMPA Sheds.pdf
Tender Document
BOQ.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .