Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC 1076 24 GIRIRAJ CO OP HSG SOC GROUND FLOOR OLD CHATURSHRINGI ROAD PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹32.3 L | L1 | Accepted-AOC L1-Ok |
| 2 | L2₹34.4 LRejected-AOC | ₹34.4 L | L2 | Rejected-AOC L2-Reject |
| 3 | Rejected-Technical 104 JASH APARTMENT NEAR LAXMI NARYAN MANDIR MAHIM ROAD PALGHAR TAL PALGHAR DIST THANE 401404 | PALGHAR | THANE | MAHARASHTRA | 401404 | - | - | Rejected-Technical Document Not Submitted As Per NIT Hence Disqualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Document Not Submitted As Per NIT Hence Disqualified |
| Sl No | Description | Qty | Unit | GURUPRASAD ENTERPRISES L2 | Avishkar Engineers Pvt. Ltd. L1 |
|---|---|---|---|---|---|
| 1.00Cat (A) - (Please reffer the tender document for Schedule B item description) | |||||
| 2.001) Providing and erecting Vacuum breaking valve as per AWWA C-512 with 3 tier screening mechanism and cylindrical float mechanism for modulating air pressure under high differential pressure conditions. Body of SGI 500/7 grade, all internals of SS316L, CSK bolting for tamperproof mechanism and dust cover of carbon steel. | |||||
| 3.00 | 1.1) 150 mm Dia. P.N.1.6 | 9 | Number | 1,12,500 ₹10,12,500 | 98,653 ₹8,87,877 Lowest |
| 4.00 | 1.2) 100 mm Dia. P.N.1.6 | 1 | Number | 77,712 ₹77,712 Lowest | 93,721 ₹93,721 |
| 5.002) Providing and erecting Vacuum breaking valve as per AWWA C-512 with 3 tier screening mechanism and cylindrical float mechanism for modulating air pressure under high differential pressure conditions. Body of SGI 500/7 grade, all internals of SS316L, CSK bolting for tamperproof mechanism and dust cover of carbon steel. | |||||
| 6.00 | 2.1) 200 mm Dia. P.N.1.6 | 6 | Number | 3,00,000 ₹18,00,000 Lowest | 3,15,733 ₹18,94,398 |
| 7.003) Providing and erecting Resilient Seated Gate valve for isolation as per BS 5163. Body & Bonnet of Ductile Iron Gr. 500/7 or 400/15. Wedge fully encapsulated WRAS approved EPDM rubber. Wedge nut of Brass. Shaft of stanless steel. Stem seal of NBR. Internal fastners of SS. Flange drilling as per IS:1538 raised face & pressure testing as per IS:14845.Flange drilling as per IS:1538 raised face & pressure testing as per IS:14846. | |||||
| 8.00 | 3.1) 150mm Dia. P.N.1.6 | 9 | Number | 30,000 ₹2,70,000 | 20,014 ₹1,80,126 Lowest |
| 9.00 | 3.2) 100 mm Dia. P.N.1.6 | 1 | Number | 21,000 ₹21,000 | 15,610 ₹15,610 Lowest |
| 10.004) Providing and erecting Resilient Seated Gate valve for isolation as per BS 5163. Body & Bonnet of Ductile Iron Gr. 500/7 or 400/15. Wedge fully encapsulated WRAS approved EPDM rubber. Wedge nut of Brass. Shaft of stanless steel. Stem seal of NBR. Internal fastners of SS. Flange drilling as per IS:1538 raised face & pressure testing as per IS:14845.Flange drilling as per IS:1538 raised face & pressure testing as per IS:14846. | |||||
Tender Value
₹34.4 L
EMD Value
₹34,400
Closing Date
9 Mar 2026, 5:00 pmClosed
Superintending Engineer Mumbai HQ
Office of the Superintending Engineer, Mumbai, MIDC, Udyog Sarathi, Mahakali Caves Road, Andheri East, Mumbai- 93.
M and R to WSS in Tarapur Industrial area.. Replacement of air valves on pumping mains and distribution lines at Tarapur.
2026_MIDC_1280519_1
MIDC_Replacement of air valves on pumping mains_EC_34,36,887
Open Tender
Support/Maintenance Service
Item Rate
180 days
Tarapur Industrial Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,030
₹34,400
29 Apr 2026
23 Feb 2026
11 Mar 2026
23 Feb 2026
9 Mar 2026
23 Feb 2026
23 Feb 2026 - 26 Feb 2026
Cat (A) - (Please reffer the tender document for Schedule B item description)
1) Providing and erecting Vacuum breaking valve as per AWWA C-512 with 3 tier screening mechanism and cylindrical float mechanism for modulating air pressure under high differential pressure conditions. Body of SGI 500/7 grade, all internals of SS316L, CSK bolting for tamperproof mechanism and dust cover of carbon steel.
1.1) 150 mm Dia. P.N.1.6
1.2) 100 mm Dia. P.N.1.6
2) Providing and erecting Vacuum breaking valve as per AWWA C-512 with 3 tier screening mechanism and cylindrical float mechanism for modulating air pressure under high differential pressure conditions. Body of SGI 500/7 grade, all internals of SS316L, CSK bolting for tamperproof mechanism and dust cover of carbon steel.
2.1) 200 mm Dia. P.N.1.6
3) Providing and erecting Resilient Seated Gate valve for isolation as per BS 5163. Body & Bonnet of Ductile Iron Gr. 500/7 or 400/15. Wedge fully encapsulated WRAS approved EPDM rubber. Wedge nut of Brass. Shaft of stanless steel. Stem seal of NBR. Internal fastners of SS. Flange drilling as per IS:1538 raised face & pressure testing as per IS:14845.Flange drilling as per IS:1538 raised face & pressure testing as per IS:14846.
3.1) 150mm Dia. P.N.1.6
3.2) 100 mm Dia. P.N.1.6
4) Providing and erecting Resilient Seated Gate valve for isolation as per BS 5163. Body & Bonnet of Ductile Iron Gr. 500/7 or 400/15. Wedge fully encapsulated WRAS approved EPDM rubber. Wedge nut of Brass. Shaft of stanless steel. Stem seal of NBR. Internal fastners of SS. Flange drilling as per IS:1538 raised face & pressure testing as per IS:14845.Flange drilling as per IS:1538 raised face & pressure testing as per IS:14846.
4.1) 200 mm Dia. P.N.1.6
Cat (B) - Buy Back Items
5) Rebate for Dismantling Air valves
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.70 MB
TenderDocument.pdf
Tender Documents • 0.26 MB
ItemSpecification.pdf
Additional Documents • 0.02 MB
BOQ_2202869.xls
BOQ • 0.28 MB
Locations.pdf
Other Document • 3.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].