Loading…
Loading…
Tender Value
₹11.2 L
EMD Value
₹28,000
Closing Date
2 Jul 2026, 11:00 pmClosed
Karnataka Power Transmission Corporation Limited
SRINIVAS T
Replacement of existing 20KA, 1I/C4F1CB of 11kV PCVCB age old ABB make breaker by 25KA MEI make Breaker and providing 2Nos of additional breaker at 66/11kV Haradanahally S/s, pertaining to Hootgally division, Mysuru-on PTK Basis-Others-CALL6
KPTCL/2026-27/SS/WORK_INDENT3866
KPTCL/2026-27/SS/WORK_INDENT3866
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Mysuru
12 documents required · 12 mandatory
The Bidder shall be registered firm as Sole Proprietorship/Partnership/Pvt Ltd Company etc
Tenderers who meet the specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under:Assessed Available Tender Capacity: (AxNx2.5-B)Where A-Maximum value of works executed (KPTCL & Non-KPTCL) in any one year during the last five years (updated to FY 2024-2025) taking into account the completed as well as works in progress. N-Number of years prescribed for completion of the works for which tenders are invited.B-Value, at FY 2024-2025 price level of existing commitments (KPTCL & Non-KPTCL)and on-going works (KPTCL & Non-KPTCL) to be completed during the next 1(One)year.Note:(i)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.(ii)A self-declaration is to be uploaded by the Tenderer stating that the information with regard to assessed available tender capacity (Works on Hand) furnished are correct.
Minimum Average Annual Turnover (MAAT) of the bidder for best two(02) year out of preceding five financial years, shall not be less than Amount Put to Tender as per 3.2(a) of std tender documents(ITT).
valid Super grade Electrical Contractor License issued by the Government of Karnataka as on the date of opening of techno-commercial bid (refer 2.3 of ITT)
For other than proprietorship, the Bidder shall furnish the registered partnership deed and Power of Attorney
Even though the Tenderers meet the above criteria, they are subject to be disqualified if they have:- Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements and/or- Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc. and/or- Participated in the previous Tender for the same work and had quoted unreasonably high Tender prices and could not furnish rational justification.
Bidder shall ensure that scanned copies of Letter of Undertaking to abide by and fulfil all the terms & conditions provisioned in the Tender document
Bidder shall ensure that scanned copies of No Deviation CERTIFICATE
Land Border - Letter of undertaking to source the equipment/material for the work from the approved Vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India (Annexure-XVI) ii. Letter of undertaking as per clause No.1.5 of Annexure-XVII iii. Letter of undertaking as per clause No.1.6 of Annexure-XVII (if applicable) are uploaded besides
ESI certificate
EPF Certificate
PAN copy
Tender shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by the Govt. of Karnataka
The Tenderer shall not be under any litigation or arbitration arising out of contracts completed or under execution by it over the last five years with KPTCL.
Tenderer/bidder should not have been Blacklisted / disqualified for non-performance in any of the Government utilities in the past five years as on date of Bid opening.
No notice issued in respect of ongoing works in the last 6 months as on date of bid submission invoking Risk & Cost clause and where the work is not completed/charged.
₹500
₹28,000
18 Jun 2026
18 Jun 2026
4 Jul 2026
25 Jun 2026
24 Jun 2026
Replacement of existing 20KA, 1I/C4F1CB of 11kV PCVCB age old ABB make breaker by 25KA MEI make Breaker and providing 2Nos of additional breaker at 66/11kV Haradanahally S/s, pertaining to Hootgally division, Mysuru-on PTK Basis-Others- CALL6
Coyote conductor
Beam out of Channel 100 x 50 with arrangements for stringing power conductor on 11 kV side (including bolts & nuts)1B2 Station Structure
11KV 90KN disc insulator
Bolted type tension clamp for Single Coyote ACSR Conductor 70/90 kN, 16 mm
Pad clamp coyote
PG Clamp for Coyote to Rabbit
C - Type Wedge Connectors Drake to coyote ACSR Conductor
C - Type Wedge Connectors Coyote to coyote ACSR Conductor
DP Structure with RCC Pole - 9 Mtr Long, 145 Kg WL
H frame for mouting GOS Set ( GI )
11 kV, 400 Amps Double Break GOS
9kV,10KA Lightning arrestor
Copper Earth Bond 450 mm long
PVC Insulation Tapes19 mm wide and in rolls of 10 Mtrs
PVC bend and T s of different sizes
11kV special 3pin cross arm-GI
RCC pole clamp-GI for running GI flat at DP and for holding PVC pipe at breaker structures
1.1 kV class Armoured Copper Cables :
Supply of 19 Core 2.5 Sqmm Copper Control Cable
1.1 kV class Armoured Copper Cables :
Supply of 4 Core 2.5 Sqmm Copper Control Cables for AC DC Extension to both control panels from ACDC and DCDB
1.1 kV class Armoured Copper Cables :
4 Core 10 Sq mm Copper cable
Cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metres long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron welding electrodes as per drawing .
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Terminal Blocks (knife type)
Current Cable - 2.5 Sq-mm multistrand copper wire for CT termination
Voltage Cable - 2.5 Sq-mm multistrand copper wire for PT termination
Control Cable - 10 Copper core x 1.5sqmm
Signal Cable - 10 Copper core x 0.5sqmm
1.5 Sqmm Grey wire for interfacing of DI and DO
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the size 2.5 sqmm
C-type channel of size 50x100x50x6mm
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
(Size: 32mm dia)
CT TB's - 6 nos for each panel
Replacement of existing 20KA, 1I/C4F1CB of 11kV PCVCB age old ABB make breaker by 25KA MEI make Breaker and providing 2Nos of additional breaker at 66/11kV Haradanahally S/s, pertaining to Hootgally division, Mysuru-on PTK Basis-Others- CALL6
11 kV PCVCB Switch gear :
1 Incomer panel+6 Feeders+1 Capacitor Bank
Erection:- a) Erection, alignment and fixing to the foundation, indoor/outdoor 11 kV switchgear panel/unit including movement from ...
Testing & Commissioning:
Identification of wires, ferruling, crimping & termination of wires for annunciation, etc.,
Testing of relays, CTs, PTs & Breaker for operation
Annunciator Panel for Two Feeders
Busbar Formation
Main bus/cross bus (all the three phases in a segment) using Coyote-single conductors, levelling of string conductors to the required height above the equipment, including providing ...
Fabrication, galvanising and supply of High tensile steel tower materialsfor Beam out of Channel 100 x 50 with arrangements for stringing power conductor on 11 kV side (including bolts & nuts)1B2 Stat...
DP Structure with RCC Pole - 9 Mtr Long, 145 Kg WL
H frame for mouting GOS Set ( GI )
11 kV, 400 Amps Double Break GOS
9kV,10KA Lightning arrestor
1.1 kV class Armoured Copper Cables :
Supply of 19 Core 2.5 Sqmm Copper Control Cable
1.1 kV class Armoured Copper Cables :
Supply of 4 Core 2.5 Sqmm Copper Control Cables for AC DC Extension to both control panels from ACDC and DCDB
1.1 kV class Armoured Copper Cables :
4 Core 10 Sq mm Copper cable
Grounding of equipments using cast iron pipe of 100 mm ID 13 mm thickness, 2.75 metres long with 2 part clamp out of G.I. Flat 50 X 6 mm continuously welded alround the pipe using cast iron welding el...
Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and conne...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Charges for Removing/spreading of Jelly from work spot by Heavy Mazdoor 2 Mazdoor X 2 days ( each person at each Bay)
Providing nameplates and painting for earth electrodes, hiring charges for welding machine for welding,cutting and drilling. Excluding all taxes.
Base concreting 1:2:4, 650x650x150 mm
Pole concreting 1:2:4, 650x650x1700 mm
Coping 1:2:4 (as per actuals)
Multi Function Transducers(MFT)
As per KPTCL Std, Interface: RS-485 Daisy Chain to RTU Com port,wiring: Both 3ph 4wire, supply: self powered, Measuring range voltage: 120%, current: 120%, frequency: 4...
Input Vtg:110V DC, input indicated by LED, input range 110VDC to 140V DC, sourcing Vtg output 48VDC, No of iputs: 12, No of outputs: 8, Source current: 5mA, at output, 8way switch to be p...
Control Cable - 10 Copper core x 1.5sqmm
Signal Cable - 10 Copper core x 0.5sqmm
1.5 Sqmm Grey wire for interfacing of DI and DO
Decomissioning of existing 11kV Indoor / Outdoor Switchgear.
De- wiring 11kV Indoor/Outdoor Switchgear
Loading of 11 kV Switchgears
(Loading at Haradanahally S/s)
UnLoading of 11 kV Switchgears
(Loading at Store)
Transportation of released Breakers etc from 66/11kV Haradanahally S/s to Divisional Major works store, Hootagalli Mysore.
Replacement of existing 20KA, 1I/C4F1CB of 11kV PCVCB age old ABB make breaker by 25KA MEI make Breaker and providing 2Nos of additional breaker at 66/11kV Haradanahally S/s, pertaining to Hootgally division, Mysuru-on PTK Basis-Others- CALL6
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT - Haradanahalli-CALL6.pdf
Instructions to Tenderers • 0.65 MB
Tender document kw1G Haradanahally C6.pdf
Tender Document • 2.28 MB
credit facility certificate FORMAT new format.doc
Commercial Information / Worksheet • 0.06 MB
Tech Volume II A B.zip
Technical Information / Worksheet • 19.19 MB
Work on Hand details format.doc
Commercial Information / Worksheet • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .