e quotation for inviting item rate for supplying installation and commissioning of HSC C/F pump at WTP of Seraikella Urban Water Supply scheme
2026_DWSD_116778_1
01/e-Quotation/2026-27
Open Tender
Pumps/Motors
Item Rate
Chaibasa
please refer tender documents
2 documents required · 2 mandatory
₹0
Exempted
13 Aug 2026
4 Aug 2026
12 Aug 2026
4 Aug 2026
11 Aug 2026
4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying all labour tools and tackles for taking out old and damaged C/F pump set with all accessories, demolition of foundation for installation of new HSC centrifugal pump sets. | - | Job | 100 | - |
| 2 | Supplying all labour tools and tackles for making PCC foundation-1 no. of size 6'x3'x2' with all materials such as cement, sand, stone chips, J-type foundation nut ,bolt with washer of M36-6nos, MS base frame-1 no, cutting and welding where necessary ,plastering and punning over exposed surface etc all complete job. | - | Job | 100 | - |
| 3 | Supplying, Installation, testing and Commissioning of single/multi stage electrically driven Horizontal split casing Centrifugal pump(make KIRLOSKAR/WPIL/WILO/M&P/JYOTI) as per IS:5120, Capable for Discharge 196m³/hr and Head 70m, consisting of Stainless Steel/Bronze impellers, stainless steel pump shaft, tyre coupling with all accessories coupled with energy efficient (IE3) TEFC Squirrel cage induction motor confirming to IS:12615 operating on 1480 rpm, 415+10% volts, 3 phase, 50HZ (make Kirloskar/ABB/CGL) all complete with required size of sluice and nonreturn valve, strainers, reducers, foot valve, pressure gauge, MS delivery and Suction pipe, common header, nuts and bolts, packing, fitting and fixing, labour and technician, etc all complete job as per site requirement
.Note:-(1). Motor capacity should have 20% above of the pump.
(2). Pressure gauge must be fitted in delivery pipe with all accessories | - | Job | 10 | - |
| 4 | Cost towards making suitable suction line By suppling of M6 Pipe, Bend, Flange, Nut, Bolt, Rubber insertion, including making hole for suction, cutting, welding etc all complete job. | - | Job | 10 | - |
| 5 | Cost towards making suitable delivery line By suppling of M6 Pipe, Bend, Flange, Nut, Bolt, Rubber insertion, including joining the new delivery line to the existing header by means of cutting, welding etc all complete. | - | Job | 10 | - |
| 6 | Main Power Distribution Panel cum MCB for Clear Water to be installed at WTP-Floor mounted cubical LT Motor Control Panel board fabricated with MS sheet of suitable guage and size dust and vermin proof and painted consisting of proper power distribution 4 pole 400A copper busbar, 1 no incoming feeder of 400A ACB(make L&T/ siemens), 4 nos. 240A MCCB(make L&T/ siemens ) for outgoing feeder of clear water pump sets (with spare feeder). 2 nos 160 A & 63 A MCCB(make L&T/ siemens ) for WTP & other Utilities, 2 nos. 32 A MCB(make L&T/ siemens ) for lighting feeder,400A switch disconnected isolator (TPN) (make L&T/Siemens),400A change over switch (make L&T /siemens), selector switches, Volt-meters, Ampere-meters, indicator lamps etc all complete with internal wiring, protection units/relays and capacitor banks of proper KVAR for Power Factor improvement for pump sets and other equipments, etc. all complete as per site requirement. Instruction
of E/l and IE rules. | - | Job | 10 | - |
| 7 | Providing erecting and commissioning of assembled fully automatic star delta starter in a provided cubical pannel to operate squirrel cage induction motor working on 380-440 Volt, 3 Phase, 50 Hz with no volt coil, over load relay and ON/OFF push buttons, with necessary material and connected to supply etc complete. | - | Job | 11 | - |
| 8 | Servo controlled Automatic voltage stabilizer: supplying Installation, testing & commissioning of 200 KVA servo controlled Automatic voltage stabilizer suitable for out put voltage of 415 volt +/-1%, 3 ph. 50 Hz with copper wound transformer (oil cooled). The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. protections and indications shall be incorporated with over voltage/ under voltage, single phasing & cut off contactor with electronic output sensing unit, including T-oil, 400A change over switch (make L&T /siements), etc all complete. | - | Set | 12 | - |
| 9 | Providing, erecting, and commissioning of power wiring with required 70 sq. mm. 3.0 core 1.1 kV grade unarmored copper cable XLPE/PVC insulated from panel to motors including laying on wall or on floor as where required, jointing, and making proper termination kit etc all complete job. | - | Meters | 13 | - |
| 10 | Providing, erecting, and commissioning of power wiring with required 240sq. mm. 3.5 core 1.1 kV grade armored Aluminium cable XLPE/PVC insulated from transformer to motor control panel including laying on wall or on floor as where required, jointing, and making proper termination kit etc all complete.[JSOR Energy-M-334]. | - | Meters | 14 | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.91 MB
NIT012627.pdf
Tender Documents • 1.89 MB
BOQ_157888.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .