| Sl No | Description | Qty | Unit | POOJA BUILDCON CONSTRUCTION L4 | Nabhas Construction Pvt ltd L3 | Brihaspathi Technologies Limited L1 | RIRVANA ENTERPRISES PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | SH : I DSITC of 15 KWp roof top Solar power plant
Design, engineering, supply, installation, testing, and commissioning of a 15 kWp grid-connected rooftop solar power plant on the existing concrete roof (approx. 100 meters from existing LT power supply), utilizing half cut monocrystalline bifacial solar PV modules with high efficiency. The scope shall include: provision of suitable inverter featuring remote monitoring, reverse power flow protection, synchronizer compatible with existing supply, Islanding facility; supply and installation of IP65-rated DC DB/JB for connecting the Module Output with the provision for isolation, string monitoring and control for each string; all necessary AC & DC cables, MC4 connectors, communication data cables, and associated cabling on cable trays / conduits; installation of lightning protection and surge protection systems; provision of AC and DC earthing; integration and installation of a zero export device; required modifications to the existing LT power supply panel and cabling; fabrication and installation of corrosion-resistant mounting structures with waterproof, anti-leak fixing arrangements , comprehensive transportation, insurance, loading/unloading, material storage, and mobilization of manpower, obtaining all necessary clearances and approvals from CEA and APEPDCL and any other accessories, tools and services necessary for the succesfull commissioning operation etc, as per techincal specifications. | 1 | Job | 9,55,000 ₹9,55,000 | 8,00,000 ₹8,00,000 | 6,79,800 ₹6,79,800 Lowest | 7,15,000 ₹7,15,000 |
| 2.00 | Providing and applying two coats of high Albedo paint having minimum Solar Reflective Index (SRI) 108 (with Solar reflectance & thermal emittance tested as per ASTMC 1549 and ASTMC 1371 respectively), VOC less than 10 cc/gm. The coating thickness methodology of application strictly as per manufacturer's specifications as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give gaurantee for the performane of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-Charge. | 125 | Sqm | 100 ₹12,500 Lowest | 700 ₹87,500 | 980 ₹1,22,500 | 900 ₹1,12,500 |
| 3.00SH II: AICMC of 15 Kwp Solar Power Plant after 1 Year DLP Period. All inclusive Comprehensive Maintenance of 15 kWp Roof top Solar plant after DLP ( 1 Year ) as provided under the main contract including trouble shooting and breakdown maintenance etc., which includes every month visit by service engineer as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours). (Note: 1. Warranty period for PCU/ inverter is 05 years 2. Warranty period for solar PV module is 10 years and the same shall be taken in to consideration while quoting the rate for AICMC) | |||||||
| 3.01 | 1st year after DLP | 1 | EA | 65,857 ₹65,857 | 55,168 ₹55,168 | 46,879 ₹46,879 Lowest | 49,306 ₹49,306 |
| 3.02 | 2nd year after DLP | 1 | EA | 70,922 ₹70,922 | 59,411 ₹59,411 | 50,485 ₹50,485 Lowest | 53,099 ₹53,099 |
| 3.03 | 3rd year after DLP | 1 | EA | 81,060 ₹81,060 | 67,904 ₹67,904 | 57,701 ₹57,701 Lowest | 60,689 ₹60,689 |
| 3.04 | 4th year after DLP | 1 | EA | 91,193 ₹91,193 | 76,392 ₹76,392 | 64,914 ₹64,914 Lowest | 68,275 ₹68,275 |
| 3.05 | 5th year after DLP | 1 | EA | 1,01,328 ₹1,01,328 | 84,882 ₹84,882 | 72,129 ₹72,129 Lowest | 75,864 ₹75,864 |
Tender Value
₹16.3 L
EMD Value
₹48,800
Closing Date
10 Jul 2025, 5:00 pmClosed
Asst GM Engg (E)
O/o AIRPORT DIRECTOR,VISAKHAPATNAM AIRPORT,VISAKHAPATNAM
Design, Supply, Installation, Testing and Commissioning of Roof Top Grid Connected 15kWp Solar Photo Voltaic (PV) Power Plant at MSSR Building, Yarada Hills, Visakhapatam
2025_AAI_235372_1
AAI/VZ/ENGG-E/CW/SOLAR/25-26
Open Tender
Electrical Works
Item Rate
90 days
MSSR, YARADA HILLS, VISAKHAPATNAM
NOTICE INVITING e-TENDER (eNIT)
21 documents required · 21 mandatory
₹1,180
₹48,800
3 Sept 2025
18 Jun 2025
11 Jul 2025
19 Jun 2025
10 Jul 2025
19 Jun 2025
19 Jun 2025 - 5 Jul 2025
Amount
SH : I DSITC of 15 KWp roof top Solar power plant Design, engineering, supply, installation, testing, and commissioning of a 15 kWp grid-connected rooftop solar power plant on the existing concrete roof (approx. 100 meters from existing LT power supply), utilizing half cut monocrystalline bifacial solar PV modules with high efficiency. The scope shall include: provision of suitable inverter featuring remote monitoring, reverse power flow protection, synchronizer compatible with existing supply, Islanding facility; supply and installation of IP65-rated DC DB/JB for connecting the Module Output with the provision for isolation, string monitoring and control for each string; all necessary AC & DC cables, MC4 connectors, communication data cables, and associated cabling on cable trays / conduits; installation of lightning protection and surge protection systems; provision of AC and DC earthing; integration and installation of a zero export device; required modifications to the existing LT power supply panel and cabling; fabrication and installation of corrosion-resistant mounting structures with waterproof, anti-leak fixing arrangements , comprehensive transportation, insurance, loading/unloading, material storage, and mobilization of manpower, obtaining all necessary clearances and approvals from CEA and APEPDCL and any other accessories, tools and services necessary for the succesfull commissioning operation etc, as per techincal specifications.
Providing and applying two coats of high Albedo paint having minimum Solar Reflective Index (SRI) 108 (with Solar reflectance & thermal emittance tested as per ASTMC 1549 and ASTMC 1371 respectively), VOC less than 10 cc/gm. The coating thickness methodology of application strictly as per manufacturer's specifications as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give gaurantee for the performane of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-Charge.
SH II: AICMC of 15 Kwp Solar Power Plant after 1 Year DLP Period. All inclusive Comprehensive Maintenance of 15 kWp Roof top Solar plant after DLP ( 1 Year ) as provided under the main contract including trouble shooting and breakdown maintenance etc., which includes every month visit by service engineer as required as per good engineering practice, recommendation of the manufacturer, instructions of Engineer-in-Charge and as per terms and conditions specified (the response time in case of breakdown shall not be more than 8 hours). (Note: 1. Warranty period for PCU/ inverter is 05 years 2. Warranty period for solar PV module is 10 years and the same shall be taken in to consideration while quoting the rate for AICMC)
1st year after DLP
2nd year after DLP
3rd year after DLP
4th year after DLP
5th year after DLP
RIRVANA ENTERPRISES PRIVATE LIMITED (BID ID -868888)
Nabhas Construction Pvt ltd (BID ID -869243)
POOJA BUILDCON CONSTRUCTION (BID ID -871476)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .