| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.7 L+₹47,921.30 (2.06%)Rejected-Finance 65 RANJEET NAGAR NEAR SAI HOSPITAL AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹25.4 L+₹2.2 L (9.27%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹31.3 L+₹8.1 L (34.8%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹37.0 L+₹13.7 L (59.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹35.7 L
EMD Value
₹1.1 L
Closing Date
19 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT 133001
DAY TO DAY HT LT COMPLAINT FOR ELECTRIC DISTRIBUTION NETWORK AND ALLIED WORKS OF ALPHA POWER HOUSE AND ALLENBY LINE POWER HOUSE IN SECTOR C UNDER GE UTILITY AMBALA CANTT
2022_MES_519122_1
CA NO GE U AMB T 05 OF 2022-23
Open Tender
Civil Works
Item Rate
330 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹1.1 L
Yes
11 Jun 2022
21 Apr 2022
21 May 2022
21 Apr 2022
19 May 2022
5 May 2022
21 Apr 2022 - 30 Apr 2022
60 days
Amount
Labour only for attending complaint under Alpha Power House of HT electric distribution network UG /OH in day to day maintenance by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include to visual inspection of OH lines, Earth Resistance of transformer, switch gear GOD etc. Quoted rate shall also include excavation of faulty cable and making seviceable with accessories like joints, Fuze wire for GOD`s Note ‘A’ (i) Cost of materials for laying of cables strecthing of OH conductor, burnt out joints, fuse wires, insulator and jumper will be measured and paid separately under relevant items as supply only being labour element is deemed to be included in the cost for said item. (ii) All T&P required for electrification work shall be provided by contractor at own arrangements to the trades men & helpers. (iii) Contractor will deploy following well experienced and well conversant manpower against this item during round the clock (03 shifts) Electrician -01 No & Helper-02 Nos at a time for attending HT distribution complaint all working days including Sunday & all Holidays. (iv) Contractor will provide well experienced and well conversant of one person for lodging the HT/LT complaint in complaint cell of each Power House during working hours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays.
Labour only for attending complaint under Allenby Line Power House of HT electric distribution network UG /OH in day to day maintenance by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include to visual inspection of OH lines, Earth resistance of transformer, switch gear GOD etc. Quoted rate shall also include excavation of faulty cable and making seviceable with accessories like joints, Fuze wire for GOD`s Note ‘A’ (i) Cost of materials for laying of cables strecthing of OH conductor, burnt out joints, fuse wires, insulator and jumper will be measured and paid separately under relevant items as supply only being labour element is deemed to be included in the cost for said item. (ii) All T&P required for electrification work shall be provided by contractor at own arrangements to the trades men & helpers . (iii) Contractor will supply following well experienced and well conversant manpower against this item during round the clock (03 shifts) Electrician -01 No & Helper -02 Nos at a time for attending HT distribution complaint all working days including Sunday & all Holidays. (iv) Contractor will provide well experienced and well conversant of one person for lodging the complaint in complaint cell of each power house during working hours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays.
Labour only for attending complaint under Alpha Power House of LT electric distribution network UG/OH of all nature like No light, faulty insulator, broken conductor& cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc upto DB in buildings/OTM in Sector `C` area complete all as specified and as directed by Engineer-in-Charge. Cost of aluminium lugs saddle of any size for fixing of cables on walls, for finishing work and all fixing accessories required for rectifying the complaints items are included in the rate quoted by Contractor. Note ‘A’:- (i) Cost of materials for laying of cables strecthing of OH conductor, burnt out MCBs, MCCB`s will be measured and paid separately under relevant items as supply only being labour element is deemed to be included in the cost for said item. (ii) All T&P required for electrification work shall be provided by contractor at own arrangements to the trades men & helpers . (iii) Contractor will deploy following well experienced and well conversant manpower against this item during round the clock (03 shifts) Electrician -01 No & Helper-02 Nos at a time for attending LT distribution complaint all working days including Sunday & all Holidays.
Labour only for attending complaint Allenby Line Power House of LT electric distribution network UG /OH of all nature like No light, faulty insulator, broken conductor& cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc upto DB in buildings/OTM in Sector `C` area complete all as specified and as directed by Engineer-in-Charge. Cost of aluminium lugs saddle of any size for fixing of cables on walls, for finishing work and all fixing accessories required for rectifying the complaints items are included in the rate quoted by contractor. Note ‘A’:- (i) Cost of materials for laying of cables strecthing of OH conductor, burnt out MCBs, MCCB`s will be measured and paid separately under relevant items as supplyb only being labour element is deemed to be included in the cost for said item. (ii) All T&P required for electrification work shall be provided by contractor at own arrangements to the trades supply only. (iii) Contractor will deploy following well experienced and well conversant manpower against this item during round the clock (03 shifts) Electrician -01 No & Helper -02 Nos at a time for attending LT distribution complaint all working days including Sunday & all Holidays. Note for items No 01 to 04 (i) The contractor may have to provided additional resources as per the direction of Engr-in-Charge for speedy disposal of complaints as and when required. Penal recovery at the rate of Rs 500/- per complaint per hour will be levied from the contractor in case of late attending of complaint after reasonable time or 2 hours whichever is more as decided by Engr-in-Chage/GE. (ii) The scope of work covered all complaints received from above concern power houses will be lodged/docketed/attended/completed. The completion will be rendered on complaint register as well as on docket and same shall be produced at the time of payment. Nature of fault may occurs given below:-
Blown out fuses
Faulty Insulator
Loose GOD male & female contact
Fault cable joint
O/H conductor broken
Broken jumpers
Tightening of stay
Stretching of broken loose fault conductor and binding on insulators up to 3 span
Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Wrench, Rope, Bamboo ladder, search light and other tools and will maintain them in working condition all the time.
Tightening of service connection as preventive maintenance
Proper Uniform shall be provided by the contractor for pers employed on duty as desired by Engr-in-Charge.
Tracing fault manually in LT/HT electric lines and underground cable network
AC Complaints like connection / disconnecting
Fault HT/LT switchgears
Switching ON/OFF street lights at appropriate time as directed by JE/Engr-in-Charge. Penel recovery for Rs 100/- per day will be recovered if street light not put ON/OFF at appropriate time.
The area covered under the above power house consists of HT/LT overhead lines. HT/LT underground cables, distribution transformers, HT/LT switch gears etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area.
Any other electric complaint which is considered essential by the department.
Confirmation on completion of any nature of major complaints will be intimated to JE concerned to the area or Engr-in-Charge immediately.
Contractor will prepare the summary of complaints attended on monthly basis as per performa given by Engr-in-Charge. The summary will be submitted to Engr-in-Carge duly signed by JE and contractor at the end of month.
The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour Commissioner Act. He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue.
Insurance, Education Qualification and experience cert for the personnel employed on duty shall be submitted to Engr-in-Charge before take over the installation.
The contractor will provide the rain coats, gum boot and hand gloves in winter and summer season.
Contractor will have no rights to object the work carrying out by other contractor at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over the assets will be carried out between the agencies.
Labour only for carry out visual inspection of transformer once in month including minor maintenance like dusting, tightening of loose connection HT/LV Side and replacement of aluminium terminal and checking of transformer oil level, top up if required, checking of silca gel, heating/replacement of silca gel all as specified and as directed. T&P required for the job is deemed to be included in contract. The record of the same will be submitted in the performa as directed by Engr-in-Charge.
Trimming of Tree branches falls into OH lines of HT/LT & minimum clearance of 3 Mtr from branches, proper shutdown will be taken and maintained in the register complete all as specified and as directed.
Maintenance of sub Station including cleaning In /out of surroundings areas, zeroing of grass in two pole & four pole str ,loose filling of sands/pebbles as required,operations of GODs, Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained Quarterly and signed by JE E/M & Engr-in-Charge all as specified and directed by Engr -in-Charge.
Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight through joint of size 95-185 Sqmm. Notes (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges demed to be included in the quoted rate. (b) Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will lived Rs 500/ per hour. (d) Straight through joint , 95 to 185, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate.
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4.0 x 25-50 Sqmm.
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm.
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm.
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.50 240-300 Sqmm.
Supply only only straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4 x 25-50 Sqmm.
Supply only straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm.
Supply only straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm.
Supply only in replacement of old UNSV shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed.
Supply only in replacement of old UNSV pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm hight and 65 mm dia with GI spindle two washer and one GI nut.
Supply only in replacement of aluminium conductor steel reinforced (ACSR).
Supply only 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core.
Supply only in replacement of MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type with thermal magnetic release complete all as specified and directed.
Supply only in replacement MCCB TPN 250 Amps, 415 Volts, 40 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type.
Supply only in replacement of MCCB TPN 160 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type.
Supply only in replacement MCCB TPN 100 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type.
Supply only aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm
Supply only aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm
Supply only aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm
Suply only chemical (Round up) for remove unwanted vegitation/grass at various locations .
Supply only straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 70-120 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply only straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 150-240 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply only cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 70-120 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply only cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 150-240 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply only LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed by Engr-in-Charge.
Supply only LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 5 line as per IS complete all as specified and directed by Engr-in-Charge.
Re-stretching existing/retrieved ACSR conductor on LT /HTpole and binding conductor on insulator properly using new binding wire/jumper wire complete all as directed by Engr-in-Charge. Note : (i) Each Run of line conductor shall be measured & paid for separately.
Supply only in replacement of steel nuts, bolts, washers of any size required at site as specified and directed by Engineer-in-Charge.
Material and Labour danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enameled white with letters, figures , and conventional skull and bone in signal red colour and fixed with MS clamps bolts approved size ofr HT 25cmx20 cm.
Supply only of PVC self adhesive insulation tape of Size .125mm x 25mm x 25 mtr long ISI marked all as specified and as directed.
Supply only for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading complete all as per direction of Engr-in-Charge.
Anti climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
M&L for providing plain cement concrete type C-2, 1:3:6 (using 40 mm graded crushed stone aggregate) as in coping, finished even and fair, including necessary from work all as directed.
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified including taking down the old cross arms bracing complete all as directed.
Supply only pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and as directed by Engr-in-Charge. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
Labour only in replacement of silica gel 4-6 mesh suitable for transformers breather and protect VCBs, RMUs from moisture at 11 KV stations as per site requirement complete, all as specified and as directed.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete as directed by Engineer-in-Charge (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge.
M & L sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as spcified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as spcified and as directed by Engineer-in-Charge.
Note:- Amount of credit schedule Rs. 25760.00 for retrieved materials as mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
BAL SINGH & SONS
kapil enterprises
Raman Electric Trading Co
STANDARD ELECTRIC COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .